1234 Main St.
Santa Rosa Beach, FLORIDA (FL) 32459
10/13/2019 9:00AM

Sample agent
agent

Agent Name

Agency Name
75
Items Inspected
18
Recommendation

Terms Of Home Inspection

Thank you very much for choosing us to perform your home inspection. "The home Inspection is a LIMITED VISUAL AND NON-INVASIVE INSPECTION of the SYSTEMS of the home that are REASONABLY ACCESSIBLE." The inspection report is a report of the SYSTEMS as set forth in the Standards of Practice (SOP) of the Florida InterNational Association of Certified Home Inspectors (FLNACHI), and the Business and Professions Code which defines a real estate inspection as a survey and basic operation of the SYSTEMS and components of a building which can be reached, entered or viewed without difficulty, nothing more nothing less. This (SOP) document defines the scope of a home inspection and can be found at our website at https://www.30apropertyinspections.com/home-inspections-standards-of-practice. Clients sometimes assume that a home inspection will include many things that are beyond the scope of the (SOP). We encourage you to read the Standards of Practice so that you clearly understand what is included in the home inspection and home inspection report.

The report has been prepared for the exclusive use of the client and the findings in the home inspection report are for the "CLIENT" only. The inspection company is not obligated to release report to any other parties without permission from client. No use by third parties is intended. We will not be responsible to any parties for the contents of the report, other than the party named herein. The report is effectively a snapshot of the house, recording the conditions on a given date and time. Home inspectors cannot predict future behavior, and as such, we cannot be responsible for things that occur after the inspection.

IMPORTANT NOTE: If Repair/Replace or Further Evaluation is written in any of the SYSTEMS throughout this Inspection Report, it is Recommended that you contact a qualified licensed contractor and or specialist in that particular area to evaluate this deficiency and the identified system to provide repair/replacement options and probable costs prior to the end of your inspection contingency period. Your inspector does not provide estimates to potential costs on repair/replacement items because the inspector does not perform repairs.

TERMS OF THE INSPECTION:

SERVICEABLE: It is the inspectors opinion that this item is doing the job for which it was intended and exhibits normal wear and tear.

RECOMMENDATION: It is the inspectors opinion that this SYSTEM is in need of further investigation and/or repairs, or appears to be at the end of its service life. The inspector has made the client aware of this situation by recommending contacting a qualified professional in the home inspection report. It is now the CLIENT's responsibility to take appropriate action concerning the SYSTEMS mentioned with the appropriate licensed professional before the end of the inspection contingency period and prior to the close of escrow.

DEFICIENCY: It is the inspectors opinion that this SYSTEM is either a safety hazard or not functioning properly. The inspector has made the client aware of this situation by calling it NOT ACCEPTABLE in this home inspection report and it is now the clients responsibility to take appropriate action concerning the SYSTEMS with the appropriate qualified licensed professional before the end of the inspection contingency period and prior to the close of escrow.

A real estate home inspection report provides written documentation of material defects discovered in the inspected buildings SYSTEMS and components which in the opinion of the inspector are safety hazards, are not functioning properly or appear to be at the end of their service life. The report may include the inspectors recommendations for correction or further evaluation. Inspections performed in accordance with these Standards of Practice are not technically exhaustive and shall apply to the primary building and its associated primary parking structure.

A property inspector is a generalist and the inspection is conducted along generalist guidelines as listed above. The generalist's job is to note material defects in the subject property he/she is inspecting. When he/she observes and finds one or more problems in a system of the property that affects its performance he/she may then refer the entire system over to a specialist in that field for a further detailed investigation. The specialist is expected to conduct a more detailed examination on that system from his specialist sphere of knowledge and training to determine all the problems with the system and the related costs of repairs. The specialist is inspecting from a depth of knowledge and experience that the generalist does not have "The home inspector is not a specialist in this specific system. it is expected that when a licensed contractor who specializes in this SYSTEM inspects the complete system, he/she may find more conditions than the home inspector. This is the reason the home inspector calls out for a complete inspection of this SYSTEM by a licensed professional.

1 - Inspection Details

In Attendance
Inspector Only
Occupancy
Furnished, Vacant
Style
Beach House
Temperature (approximate)
85 Fahrenheit (F)
Type of Building
Detached, Single Family
Weather Conditions
Partly Cloudy
Closets Locked

The photographed closets were locked at the time of inspection and were not inspected. 

2 - Roof

IN NI NP D
2.1 Coverings X
2.2 Roof Drainage Systems X
2.3 Flashings X
2.4 Skylights, Chimneys & Other Roof Penetrations X
Inspection Method
Binoculars, Ladder
Roof Type/Style
Gable
Coverings: Roof Condition
Good

Observation of the overall condition of the roof at time of inspection. 

Roof Drainage Systems: Gutter Material
None
Flashings: Material
Metal
Coverings: Material
Metal

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency

3 - Exterior

IN NI NP D
3.1 Siding, Flashing & Trim X
3.2 Exterior Doors X
3.3 Walkways, Patios & Driveways X
3.4 Decks, Balconies, Porches & Steps X
3.5 Eaves, Soffits & Fascia X
3.6 Vegetation, Grading, Drainage & Retaining Walls X
3.7 Fence X
Siding, Flashing & Trim: Siding Material
Fiber Cement, Wood
Siding, Flashing & Trim: Siding Style
Batten, Clapboard
Exterior Doors: Exterior Entry Door
Glass, Wood
Decks, Balconies, Porches & Steps: Appurtenance
Balcony, Covered Porch, Deck with Steps
Decks, Balconies, Porches & Steps: Material
Wood, Composite
Inspection Method
Visual, Crawlspace Access, Attic Access
Moisture Reading
1.7

Low reading - under 15 is most desirable.

Walkways, Patios & Driveways: Driveway Material
Brick Pavers

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
3.1.1 - Siding, Flashing & Trim

Damage - Minor

Siding showed signs of minor damage in photographed areas. This could allow moisture in, resulting in further damage. Recommend a qualified siding contractor evaluate and repair.

Credit
Comment
3.4.1 - Decks, Balconies, Porches & Steps

Deck - Loose Boards

One or more deck boards were observed to be loose - see photos. Recommend they be refastened.

Here is a helpful article for minor DIY deck repair. 

Credit
Comment
3.4.2 - Decks, Balconies, Porches & Steps

Deck - Water Sealant Recommended

Deck is showing signs of weathering and/or water damage. Recommend water sealant/weatherproofing be applied.

Here is a helpful article on staining & sealing your deck. 

Credit
Comment
3.5.1 - Eaves, Soffits & Fascia

Wasps Nests

Wasp nests were visible under the soffits. Recommend a qualified exterminator evaluate and remove.

Credit
Comment
3.6.1 - Vegetation, Grading, Drainage & Retaining Walls

Vegetation too close to home

The vegetation should not be touching the home or redirecting moisture toward the home. Recommend trimming bushes at least two feet from the structure.

Tools Handyman/DIY

4 - Foundation & Crawlspace/Structure

IN NI NP D
4.1 Foundation X
4.2 Basements & Crawlspaces X
Inspection Method
Crawlspace Access, Attic Access, Visual
Foundation: Material
Masonry Block
Foundation: Crawlspace Vapor Barriers
Spray Foam

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency

5 - Heating

IN NI NP D
5.1 Equipment X
5.2 Normal Operating Controls X
5.3 Distribution Systems X
5.4 Presence of Installed Heat Source in Each Room X
Equipment: Energy Source
Electric
Equipment: Heat Type
Forced Air, Heat Pump
Equipment: Installation Date
2014
Distribution Systems: Ductwork
Insulated
Equipment: Brand
Carrier

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
5.1.1 - Equipment

Filter Dirty

The furnace filter is dirty and needs to be replaced every 1-3 months.

6 - Cooling

IN NI NP D
6.1 Cooling Equipment X
6.2 Normal Operating Controls X
6.3 Distribution System X
6.4 Presence of Installed Cooling Source in Each Room X
Cooling Equipment: Energy Source/Type
Electric, Central Air Conditioner, Ceiling Fan
Cooling Equipment: Location
Exterior West
Cooling Equipment: Manufactured Date
2013, 2014
Distribution System: Configuration
Central
Presence of Installed Cooling Source in Each Room: Heating/Cooling Source in Every Room
Yes
Normal Operating Controls: Thermostat Brand
Trane
Cooling Equipment: Brand
Carrier
Cooling Equipment: Good Air Flow
Yes

The indoor air unit was clean and free of dust and debris. This should lead to good air flow throughout the home. 

I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
6.1.1 - Cooling Equipment

Condensate Tube Damaged

Recommend a qualified HVAC technician repair.

Fire HVAC Professional

7 - Plumbing

IN NI NP D
7.1 Main Water Shut-off Device X
7.2 Drain, Waste, & Vent Systems X
7.3 Water Supply, Distribution Systems & Fixtures X
7.4 Hot Water Systems, Controls, Flues & Vents X
7.5 Fuel Storage & Distribution Systems X
7.6 Faucets X
Filters
System flush
Water Source
Public
Main Water Shut-off Device: Location
At Meter
Drain, Waste, & Vent Systems: Drain Size
1 1/2"
Drain, Waste, & Vent Systems: Material
PVC
Water Supply, Distribution Systems & Fixtures: Distribution Material
Hose
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Copper, Pex
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Gas, Tankless
Hot Water Systems, Controls, Flues & Vents: Manufactured Date
N/A
Water Pressure
68 PSI (Pounds per Square Inch)
Hot Water Systems, Controls, Flues & Vents: Location
Exterior West
Fuel Storage & Distribution Systems: Main Gas Shut-off Location
At Tank
Hot Water Systems, Controls, Flues & Vents: Manufacturer
Rinnai

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
7.2.1 - Drain, Waste, & Vent Systems

Toilet - Water Running

The inspector running toilet water in the photographed locations. Recommend qualified plumber repair. 

Contractor Qualified Professional

8 - Electrical

IN NI NP D
8.1 Service Entrance Conductors X
8.2 Main & Subpanels, Service & Grounding, Main Overcurrent Device X
8.3 Branch Wiring Circuits, Breakers & Fuses X
8.4 Lighting Fixtures, Switches & Receptacles X
8.5 GFCI & AFCI X
8.6 Smoke Detectors X
8.7 Carbon Monoxide Detectors X
8.8 Appliances X
8.9 Doorbell X
Service Entrance Conductors: Electrical Service Conductors
Below Ground
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Capacity
200 AMP
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Manufacturer
Eaton
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Type
Circuit Breaker
Branch Wiring Circuits, Breakers & Fuses: Branch Wire 15 and 20 AMP
Copper
Branch Wiring Circuits, Breakers & Fuses: Wiring Method
Conduit
Appliances: Dishwasher
Appliances: Oven/Range/Stove
Appliances: Microwave
Appliances: Sink Disposal
Appliances: Refrigerator/Freezer
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main Panel Location
East
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Sub Panel Location
Garage

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
8.4.1 - Lighting Fixtures, Switches & Receptacles

Light/Fan Inoperable

Photographed lights/fans are not operating. Possibly new light bulb needed, but recommend a qualified electrician remedy. 

Credit
Comment
8.4.2 - Lighting Fixtures, Switches & Receptacles

Reverse Polarity

One or more receptacles have been wired with reverse polarity. This can create a shock hazard. Recommend licensed electrician evaluate & repair.

9 - Fireplace

IN NI NP D
9.1 Vents, Flues & Chimneys X
9.2 Lintels X
9.3 Damper Doors X
9.4 Cleanout Doors & Frames X
Type
Gas
Gas Supply Shut Off

Gas supply was turned off, so operation of gas fireplaces could not be verified. Recommend having gas supply turned on and operation of fireplaces confirmed before closing. 

I. The inspector shall inspect:

readily accessible and visible portions of the fireplaces and chimneys;

lintels above the fireplace openings;

damper doors by opening and closing them, if readily accessible and manually operable; and

cleanout doors and frames.

II. The inspector shall describe:

the type of fireplace.

III. The inspector shall report as in need of correction:

evidence of joint separation, damage or deterioration of the hearth, hearth extension or chambers;

manually operated dampers that did not open and close;

the lack of a smoke detector in the same room as the fireplace;

the lack of a carbon-monoxide detector in the same room as the fireplace; and

cleanouts not made of metal, pre-cast cement, or other non-combustible material.

IV. The inspector is not required to:

inspect the flue or vent system.

inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels.

determine the need for a chimney sweep.

operate gas fireplace inserts.

light pilot flames.

determine the appropriateness of any installation.

inspect automatic fuel-fed devices.

inspect combustion and/or make-up air devices.

inspect heat-distribution assists, whether gravity-controlled or fan-assisted.

ignite or extinguish fires.

determine the adequacy of drafts or draft characteristics.

move fireplace inserts, stoves or firebox contents.

perform a smoke test.

dismantle or remove any component.

perform a National Fire Protection Association (NFPA)-style inspection.

perform a Phase I fireplace and chimney inspection.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency

10 - Doors, Windows & Interior

IN NI NP D
10.1 Doors X
10.2 Windows X
10.3 Floors X
10.4 Walls X
10.5 Ceilings X
10.6 Steps, Stairways & Railings X
10.7 Countertops & Cabinets X
Windows: Window Manufacturer
Guardian
Windows: Window Type
Single-hung, Double Pane, Storm
Floors: Floor Coverings
Tile, Hardwood
Walls: Wall Material
Drywall, Wood
Ceilings: Ceiling Material
Drywall
Countertops & Cabinets: Cabinetry
Wood
Countertops & Cabinets: Countertop Material
Granite

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
10.1.1 - Doors

Door Doesn't Close or Lock Properly

Door doesn't lock in place properly. Recommend handyman repair latch, hinges or strike plate. Also recommend all doors be checked and ensured they operate as intended.


Credit
Comment
10.1.2 - Doors

Door Stops Missing

Door stops are missing in photographed areas. Recommend ensuring all interior doors have door stops to prevent damage to doors and walls. 

Contractor Qualified Professional
Credit
Comment
10.4.1 - Walls

Minor Cracks

Minor cracks in walls. Appeared to be the result of long-term settling. Some settling is not unusual in a home of this age and these cracks are not a structural concern.

Credit
Comment
10.5.1 - Ceilings

Nail Pops

Protruding nail heads visible at the time of the inspection, although covered with putty and paint. Recommend protruding nails be removed, drywall re-fastened and the drywall finished to match the existing wall surfaces. All work should be performed by a qualified drywall or painting contractor.

Contractor Qualified Professional

11 - Built-in Appliances

IN NI NP D
11.1 Dishwasher X
11.2 Refrigerator X
11.3 Range/Oven/Cooktop X
11.4 Garbage Disposal X
11.5 Built-in Microwave X
11.6 Bathroom Fan(s) X
11.7 Washer and Dryer X
Dishwasher: Manufactured Date
2014
Refrigerator: Manufactured Date
2014
Range/Oven/Cooktop: Range/Oven Energy Source
Electric, Gas
Range/Oven/Cooktop: Manufactured Date
2014
Built-in Microwave: Manufactured Date
2014
Range/Oven/Cooktop: Exhaust Hood Type
Vented
Dishwasher: Brand
GE
Refrigerator: Brand
GE
Range/Oven/Cooktop: Range/Oven Brand
GE
Built-in Microwave: Microwave Brand
GE
Washer and Dryer: Brand
Kenmore
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
11.2.1 - Refrigerator

Damage

Refrigerator showed signs of damage in photographed areas. 

Contractor Qualified Professional
Credit
Comment
11.7.1 - Washer and Dryer

Dryer Vent Exterior Cover

Missing/Damaged at the time of inspection. Recommend replacing. 

Contractor Qualified Professional

12 - Attic, Insulation & Ventilation

IN NI NP D
12.1 Attic Insulation X
12.2 Roof Decking X
12.3 Vapor Retarders (Crawlspace and/or Attic) X
12.4 Ventilation X
12.5 Exhaust Systems X
Attic Insulation: Moisture Reading
5.1
Ventilation: Ventilation Type
Ridge Vents, Soffit Vents
Exhaust Systems: Exhaust Fans
Fan Only
Attic Insulation: Insulation Type
Blown
Attic Insulation: Thickness or R-Value
12.75

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency

13 - Garage

IN NI NP D
13.1 Ceiling X
13.2 Floor X
13.3 Walls & Firewalls X
13.4 Garage Door X
13.5 Garage Door Opener X
13.6 Occupant Door (From garage to inside of home) X
Type
one car, attached
Garage Door: Material
Metal, Insulated
Garage Door: Type
Up-and-Over, Automatic
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
13.2.1 - Floor

Cracking

Cracking visible in the garage floor. This is common and not a structural concern. Monitor the cracked areas over time for any signs of moisture intrusion or increase in size. 

Credit
Comment
13.3.1 - Walls & Firewalls

Cracking - Minor