1 - General Information / Overview

General: General: Scope of Inspection

4 PAR HOME INSPECTIONS performs all inspections in compliance with the Standards of Practice of the International Association of Certified Home Inspectors (InterNACHI).  We inspect the readily accessible, visually observable, installed systems and components of a home as designated in the InterNACHI Standards of Practice. When systems or components designated in the InterNACHI Standards of Practice are present but are not inspected, the reason(s) the item was not inspected is identified within the Limitations tab of this report. This home inspection is not a compliance inspection or certification of any kind. It simply is an inspection of the condition of the home at the time of the inspection. This inspection does not cover items or conditions that may be only discovered by invasive methods. No removal of materials or dismantling of systems shall be performed under this inspection. This is not a technically exhaustive inspection. 

General: General: Using This Report - Scope & Limitations

The Inspection Is Not A Pass/Fail

A home does not "Pass" or "Fail" a General Home inspection. The goal is to provide useful, accurate information about the condition of the home.  Please feel free to contact me with any questions about either the report or the property. 


Using The Report Summary

The summary is meant to organize the defects or important repairs needed in the home. Most anything can be repaired in a home, although some repairs can be very expensive to complete. Generally, normal maintenance issues are left out of the summary unless they would lead to water leaks, expensive repairs, or unreasonable risk to people or property if not completed in a timely manner. Roof maintenance issues will be included in the summary because of the severe damage that may be caused by the neglect of roof maintenance.


Explanation of Categories and Ratings:

Below are the categorizations used in this home home inspection report.  The categorizations assigned are the professional opinion of the home inspector and based on what was observed at the time of inspection.  The categorizations should not be construed as to mean that items designated as "Minor Defects" or "Recommendations" do not need repairs or replacement. The recommendation in the text of the comment is important in addition to the categorization. Due to your opinions or personal experience you may feel defects belong in a different category, and you should feel free to consider the importance you believe they hold when reviewing the home inspection report.  

I = Inspected:  This means the system or component was inspected and found to be functioning properly, or in acceptable condition at the time of the inspection. No further comment is necessary but whenever possible additional information about materials used in the construction and how to care for or maintain the home is provided.

NI = Not Inspected:  This indicates that at least part of a system or component could not be inspected or inspected thoroughly.

NP = Not Present:   This indicates that a system or component was not present at the time of inspection. If the system or component should have been present, a comment will follow.

O = Observation:  This indicates that an action is recommended. Observations are color coded to indicate the importance of the observation.

BLUE - MINOR CONCERN:   Maintenance items, DIY items, or recommended updates will fall into this category. These concerns will ultimately lead to Moderate Concerns and Major Concerns if left neglected for extended periods of time. These Concerns may be more straightforward to remedy

ORANGE - MODERATE CONCERN:  Most items will fall into this category. Concerns that inevitably lead to, or directly cause (if not addressed in a timely manner) adverse impact on the condition of the home, or unreasonable risk (Unsafe) to people or property. These concerns typically require further evaluation or may be more complicated to remedy.

RED - MAJOR CONCERN:   The item, component or system poses a safety concern to occupants in or around the home. Some listed concerns will be considered acceptable for the time period of construction but pose a current risk.  The item, component or system is Not functioning as intended, or needs further evaluation by a specialized qualified licensed contractor or can cause damage to the structure. Items, components or units that can be repaired to satisfactory condition may not need replacement.


THE HOME INSPECTION IS NOT A WARRANTY

The home inspection report is  NOT intended to be considered as a  GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED, REGARDING THE CONDITIONS OF THE PROPERTY, INCLUDING THE ITEMS AND SYSTEMS INSPECTED, AND IT SHOULD NOT BE RELIED ON AS SUCH.


OUTSIDE THE SCOPE OF THE HOME INSPECTION

The following areas/components not included in the scope of this inspection (unless otherwise noted):

  •    Structural integrity
  •    Geological stability or ground condition of site,
  •    System design issues, functional adequacy, operational capacity, quality or suitability for particular use of items inspected,
  •    Fireplace and flue draft,
  •    Capacity for the garbage disposal to grind food or the dishwasher to clean properly,
  •    Cosmetic items including, but not limited to minor scratches, scrapes, dents, cracks, stains, soiled or faded surfaces, 
  •    Wells or well pumps, & Septic Systems
  •    Cisterns
  •    Sewer lines beyond the foundation wall and not visible,
  •    Fountains,
  •    Electronic air cleaners or filters,
  •    Water quality or volume, or water conditioning systems,
  •    Environmental hazards,
  •    Active or passive solar systems,
  •    Security systems,
  •    Detached buildings or equipment unless specifically included and paid for in the agreement,
  •    Central vacuum systems,
  •    Wall or window mounted air conditioning systems

2 - Inspection Details

In Attendance
Home Owner
Occupancy
Furnished, Occupied
Style
Craftsman
Temperature (approximate)
65 Fahrenheit (F)
Type of Building
Single Family
Weather Conditions
Dry, Clear

3 - Roof

IN NI NP D
3.1 Coverings X
3.2 Roof Drainage Systems X
3.3 Flashings X
3.4 Skylights, Chimneys & Other Roof Penetrations X
Roof Type/Style
Combination
Inspection Method
Ground, Roof
Coverings: Material
Asphalt
Roof Drainage Systems: Gutter Material
Aluminum
Flashings: Material
Aluminum

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

4 - Exterior

IN NI NP D
4.1 Siding, Flashing & Trim X
4.2 Exterior Doors X X
4.3 Walkways, Patios & Driveways X
4.4 Decks, Balconies, Porches & Steps X X
4.5 Eaves, Soffits & Fascia X
4.6 Vegetation, Grading, Drainage & Retaining Walls X
Inspection Method
Crawlspace Access, Attic Access, Visual
Siding, Flashing & Trim: Siding Style
Stucco
Siding, Flashing & Trim: Exterior

Minor cracks in stucco were noted.  

Exterior Doors: Exterior Entry Door
Wood, Glass
Decks, Balconies, Porches & Steps: Material
Wood, Composite
Siding, Flashing & Trim: Siding Material
Stucco
Walkways, Patios & Driveways: Driveway Material
Concrete, Pavers
Decks, Balconies, Porches & Steps: Appurtenance
Hot Tub, Shed, Covered Porch

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
4.2.1 - Exterior Doors

Front door

Door is out of square causing uneven gaps at top and bottom. 

Door Door Repair and Installation Contractor
Credit
Comment
4.4.1 - Decks, Balconies, Porches & Steps

Covered hot tub

Roof is asphalt shingles on a 1:12 sloped roof and wont shed water properly.  Needs to be a built up roof designated for a flat roof.

Contractor Qualified Professional

5 - Basement, Foundation, Crawlspace & Structure

IN NI NP D
5.1 Foundation X
5.2 Basements & Crawlspaces X
5.3 Floor Structure X
5.4 Wall Structure X
5.5 Ceiling Structure X
Inspection Method
Crawlspace Access, Attic Access
Foundation: Material
Concrete
Floor Structure: Basement/Crawlspace Floor
Wood
Floor Structure: Material
Engineered Floor Trusses
Floor Structure: Sub-floor
Plank

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

6 - Heating

IN NI NP D
6.1 Equipment X
6.2 Normal Operating Controls X
6.3 Distribution Systems X
6.4 Vents, Flues & Chimneys X
6.5 Presence of Installed Heat Source in Each Room X
Equipment: Energy Source
Natural Gas
AFUE Rating
Attic
90.

AFUE (Annual fuel utilization efficiency) is a metric used to measure furnace efficiency in converting fuel to energy. A higher AFUE rating means greater energy efficiency. 90% or higher meets the Department of Energy's Energy Star program standard.

Equipment: Brand
York
Equipment: Heat Type
Forced Air
Distribution Systems: Ductwork
Insulated

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

7 - Cooling

IN NI NP D
7.1 Cooling Equipment X
7.2 Normal Operating Controls X
7.3 Distribution System X
7.4 Presence of Installed Cooling Source in Each Room X
Cooling Equipment: Energy Source/Type
Electric, Attic Fan, Central Air Conditioner
Cooling Equipment: Location
Exterior North
Distribution System: Configuration
Central
Cooling Equipment: Brand
York

Dual AC units present

Cooling Equipment: SEER Rating
17.0 SEER

Modern standards call for at least 13 SEER rating for new install. 

Read more on energy efficient air conditioning at Energy.gov.

I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

8 - Plumbing

IN NI NP D
8.1 Main Water Shut-off Device X
8.2 Drain, Waste, & Vent Systems X
8.3 Water Supply, Distribution Systems & Fixtures X
8.4 Hot Water Systems, Controls, Flues & Vents X
8.5 Fuel Storage & Distribution Systems X
8.6 Sump Pump X
Filters
Whole house conditioner
Water Source
Public
Drain, Waste, & Vent Systems: Material
ABS
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Copper
Hot Water Systems, Controls, Flues & Vents: Location
Garage
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Gas
Fuel Storage & Distribution Systems: Main Gas Shut-off Location
Gas Meter
Main Water Shut-off Device: Location
South
Drain, Waste, & Vent Systems: Drain Size
4”
Water Supply, Distribution Systems & Fixtures: Distribution Material
Copper
Hot Water Systems, Controls, Flues & Vents: Capacity
60 gallons
Hot Water Systems, Controls, Flues & Vents: Manufacturer
AO Smith

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

Sump Pump: Location
Outside North

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

9 - Electrical

IN NI NP D
9.1 Service Entrance Conductors X
9.2 Main & Subpanels, Service & Grounding, Main Overcurrent Device X
9.3 Branch Wiring Circuits, Breakers & Fuses X
9.4 Lighting Fixtures, Switches & Receptacles X
9.5 GFCI & AFCI X
9.6 Smoke Detectors X
9.7 Carbon Monoxide Detectors X
Service Entrance Conductors: Electrical Service Conductors
Copper, 220 Volts
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Capacity
225 AMP
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Manufacturer
Murray
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Type
Circuit Breaker
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Sub Panel Location
Interior
Branch Wiring Circuits, Breakers & Fuses: Branch Wire 15 and 20 AMP
Copper
Branch Wiring Circuits, Breakers & Fuses: Wiring Method
Conduit
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main Panel Location
Right

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

10 - Attic, Insulation & Ventilation

IN NI NP D
10.1 Attic Insulation X
10.2 Vapor Retarders (Crawlspace or Basement) X
10.3 Ventilation X
10.4 Exhaust Systems X X
Dryer Power Source
220 Electric
Dryer Vent
Metal (Flex)
Attic Insulation: Insulation Type
Loose-fill
Attic Insulation: R-value
38
Ventilation: Ventilation Type
Ridge Vents, Soffit Vents
Exhaust Systems: Exhaust Fans
Fan with Light
Flooring Insulation
Loose Fill

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
10.4.1 - Exhaust Systems

Exhaust fan

Fan in master bathroom needs to be upgraded. There is moisture damage to walls

Electric Electrical Contractor

11 - Doors, Windows & Interior

IN NI NP D
11.1 Doors X
11.2 Windows X X
11.3 Floors X
11.4 Walls X
11.5 Ceilings X
11.6 Steps, Stairways & Railings X
11.7 Countertops & Cabinets X
Windows: Window Manufacturer
Marvin
Windows: Window Type
Double-hung, Casement
Walls: Wall Material
Drywall
Ceilings: Ceiling Material
Gypsum Board
Countertops & Cabinets: Countertop Material
Granite
Floors: Floor Coverings
Hardwood, Tile
Steps, Stairways & Railings: Spiral stair to loft

Custom spiral stair

Countertops & Cabinets: Cabinetry
Wood

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
11.2.1 - Windows

#1 bedroom window on right
North

Window seal is broken in bedroom #1 allowing for moisture between panes.    

Window Window Repair and Installation Contractor

12 - Built-in Appliances

IN NI NP D
12.1 Dishwasher X
12.2 Refrigerator X
12.3 Range/Oven/Cooktop X
12.4 Garbage Disposal X
Range/Oven/Cooktop: Range/Oven Energy Source
Gas
Dishwasher: Brand
GE
Refrigerator: Brand
Sub zero
Range/Oven/Cooktop: Exhaust Hood Type
Vented
Range/Oven/Cooktop: Range/Oven Brand
Wolf

10.1 The inspector shall inspect: F. installed ovens, ranges, surface cooking appliances, microwave ovens, dishwashing machines, and food waste grinders by using normal operating controls to activate the primary function. 10.2 The inspector is NOT required to inspect: G. installed and free-standing kitchen and laundry appliances not listed in Section 10.1.F. H. appliance thermostats including their calibration, adequacy of heating elements, self cleaning oven cycles, indicator lights, door seals, timers, clocks, timed features, and other specialized features of the appliance. I. operate, or con rm the operation of every control and feature of an inspected appliance.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies