The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Deficient (D) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
After the inspection report is issued, it is recommended that the repairs be completed, or agreements made to complete the repairs before final closing. The buyer accepts all material defects, latent or exposed, upon closing. It is also recommended to have an annual reinspection performed by an inspector, or further evaluation by qualified contractors. This will ensure that repairs are made properly, as well as further evaluating systems and components over time. It is also recommended to purchase a home warranty for at least the first year in your new home.


Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.

1 - ADDITIONAL INFORMATION PROVIDED BY THE INSPECTOR

In Attendance
Buyer's Agent
Building Status
Vacant
Type of Building
Single Family One-Story
Weather
Cloudy
Temperature Approximate
68 Fahrenheit (F)
Utilities
On
Direct of Home
House Faces North for Purpose of this Inspection
Inaccessible or Obstructed Areas
Floors Covered - Tile / Carpet, Walls & Ceilings - Repaired or Freshly Painted, Plumbing Areas - Only Visible Plumbing Inspected
Mold/Mildew Investigations
are NOT included with this report; it is beyond the scope of this inspection at the present time. Any reference of water intrusion is recommended that further investigation be obtained.

INFORMATION INCLUDED UNDER "ADDITIONAL INFORMATION PROVIDED BY INSPECTOR", OR PROVIDED AS AN ATTACHMENT WITH THE STANDARD FORM, IS NOT REQUIRED BY THE COMMISSION AND MAY CONTAIN CONTRACTUAL TERMS BETWEEN THE INSPECTOR AND YOU, AS THE CLIENT. THE COMMISSION DOES NOT REGULATE CONTRACTUAL TERMS BETWEEN PARTIES. IF YOU DO NOT UNDERSTAND THE EFFECT OF ANY CONTRACTUAL TERM CONTAINED IN THIS SECTION OR ANY ATTACHMENTS, CONSULT AN ATTORNEY.

2 - I. STRUCTURAL SYSTEMS

I NI NP D
2.1 A. Foundations X
2.2 B. Grading and Drainage X
2.3 C. Roof Covering Materials X X
2.4 D. Roof Structures and Attics X
2.5 E. Walls (Interior and Exterior) X X
2.6 G. Doors (Interior and Exterior) X X
2.7 F. Ceilings and Floors X
2.8 H. Windows X
2.9 I. Stairways (Interior and Exterior) X
2.10 J. Fireplaces and Chimneys X
2.11 K. Porches, Balconies, Decks and Carports X X
2.12 L. Other X
C. Roof Covering Materials: Types of Roof Coverings
Concrete Tile, Rolled Composite
C. Roof Covering Materials: Viewed From
Roof Top
C. Roof Covering Materials: Roof Type
Hip, Flat
D. Roof Structures and Attics: Attic
None
D. Roof Structures and Attics: Viewed From
N/A
D. Roof Structures and Attics: Approximate Depth of Insulation
Not Visible
F. Ceilings and Floors: Ceiling Materials
Gypsum Board (Drywall), Plaster Texture
F. Ceilings and Floors: Floor Coverings
Carpet, Tile
H. Windows: Windows
Double Pane
J. Fireplaces and Chimneys: Types of Fireplaces
Sealed off
L. Other: Type
Concrete Driveway
A. Foundations: Type of Foundation(s)
Concrete Slab

Foundation is a slab on grade and visually appears to be performing its intended function at the time of the inspection.

The TREC inspector for this inspection is not a professional engineer. The opinions given on the performance of this structures foundation are based on the knowledge and experience of the inspector and may be subjective and may vary from the opinions of other inspectors. The inspector makes comments comprised of opinion and not fact, determinations that are factual are available via specialized qualified and licensed engineering studies, which are beyond the scope of this inspection. Future performance of the foundation is not warranted. If you note any changes / observations from this report at a later date from what has been reported herein, a re-assessment should be made by a qualified and licensed engineer / foundation contractor and appropriate action taken. The foundation inspection performed was a cursory and limited to visual observations of accessible / visible exterior and interior structural components of the house at the time of the inspection. No foundation measurements (elevation or otherwise) have been made or are within scope of this inspection.

B. Grading and Drainage: Grading and Drainage

Grading and drainage visually appear to be performing their intended function by moving water away from the home at the time of the inspection.

Maintenance tip: It is standard practice and recommendation to maintain soil levels a minimum of six (6) to eight (8) inches below the top of the slab and graded away from the slab, at a minimum rate of six (6) inches per every 10 feet, to promote positive drainage and to prevent water from pooling/standing around the foundation area(s). Standard soil levels will also reduce possible moisture exposure and help detect insect/pest activity.

C. Roof Covering Materials: Images of Roof

Roof is in good condition and appears to have been recently sealed. 

E. Walls (Interior and Exterior): Siding Material
Stucco

Maintenance tip: Sealing/caulking is recommended as part of an ongoing maintenance program. Sealing and caulking of exterior jambs and masonry junctions, threshold and
curd areas, exterior siding and trim, fascia, wall exits, and windows areas to name a few,
will help reduce possible water penetration and weather-related deterioration.

G. Doors (Interior and Exterior): Garage Door Into Dwelling
Solid Wood

Garage doors into dwelling require a fire rated door. Without a fire rated sticker on the door, we are unable to verify that doors leading into the residence from the garage area are fire rated. Most Solid Wood Doors 1-3/8" thick and Steel Doors are Fire Rated.

H. Windows: Comments

All windows were checked on the home and worked properly at the time of the inspection.

Condensation or signs of moisture between panes of double pane windows typically indicates failure of the seals and may not be visible at all times, depending on weather conditions and other factors. The inspector reports the condition of the property at the time of inspection and makes every effort to find and report all defects, but signs of failed seals may be detected after the inspection as conditions change.

H. Windows: Maintenance Tip

Maintenance tip: Sealing/caulking is recommended as part of an ongoing maintenance program. Sealing and caulking of windows will help reduce possible water penetration and weather related deterioration.

J. Fireplaces and Chimneys: Chimney (exterior)
Stucco
J. Fireplaces and Chimneys: Fireplace Maintenance

Maintaining a fireplace properly is important to help minimize potential hazards from fire or smoke. 

Click here for more information

D. Roof Structures and Attics: No Attic

The home did not have an accessible attic space and the roof structure was not visible at the time of inspection. 

The inspector shall inspect: The foundation. The crawlspace. The visible structural components. Any present conditions or clear indications of active water penetration observed by the inspector. And report any general indications of foundation movement that are observed by the inspector, such as but not limited to sheetrock cracks, brick cracks, out-of-square door frames or floor slopes.


The inspector is not required to: Enter any crawlspaces that are not readily accessible or where entry could cause damage or pose a hazard to the inspector, Move stored items or debris, Operate sump pumps with inaccessible floats, Identify size, spacing, span, location or determine adequacy of foundation bolting, bracing, joists, joist spans or support systems, Provide any engineering or architectural service, Report on the adequacy of any structural system or component.

  • I = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficient
Credit
Comment
2.3.1 - C. Roof Covering Materials

Fasteners/Nails Underdriven

A few fasteners/nails were under driven or protruding though the overlying shingles. This should be corrected to help prevent moisture intrusion into the roof structure.

Credit
Comment
2.5.1 - E. Walls (Interior and Exterior)

Moisture Detected on Interior Wall
Location: Laundry Room

Thermal imaging and/or a moisture meter indicated the possibility of moisture in interior wall, this may be an indication of a leak. Recommend further evaluation  by a qualified professional to determine cause and if any corrective measure needs to be taken.

Credit
Comment
2.5.2 - E. Walls (Interior and Exterior)

Minor Stucco Cracks
Location: Westside Wall By Window & Back Wall

Minor cracks were observed in the stucco around the home. These cracks should be sealed with a stucco crack flex sealant to prevent further expansion and moisture penetration into the home structure by a qualified professional. 

Credit
Comment
2.5.3 - E. Walls (Interior and Exterior)

Wood Trim - Damaged/Deteriorated
Location: Garage Door Trim

Exterior wood trim was found to be damaged and or deteriorated. This should be repaired to help prevent further damage to trim. 

Credit
Comment
2.5.4 - E. Walls (Interior and Exterior)

Exterior Wall - Penetrations Not Sealed

Exterior water lines at the exterior wall intersection had gaps and were not properly sealed. These lines should be sealed with an approved sealant at the wall penetrations to prevent moisture from getting into the structure of the home. 

Credit
Comment
2.5.5 - E. Walls (Interior and Exterior)

Water Stains On Wall
Location: Bedroom Facing Street

Water Stains visible on the interior wall at the time of inspection which may be from a previous leakage. The moisture meter and/or thermal imaging was negative for moisture at time of inspection, which may suggest the leak has been repaired.

Credit
Comment
2.6.1 - G. Doors (Interior and Exterior)

Double Keyed Deadbolt
Location: Exterior Screen Doors

A door to the exterior had a deadbolt which required a key for operation from the inside. This condition is unsafe as it may slow or prevent exit during an emergency. Installation of these types of deadbolts is no longer a standard practice in new construction. The Inspector recommends that all deadbolts in the home that require a key for exit from the home interior be replaced with a deadbolt that operates from the inside with a lever. 

Credit
Comment
2.11.1 - K. Porches, Balconies, Decks and Carports

Common Cracks
Location: Back Porch

Common cracks were visible in the sidewalk/porch cement at the time of the inspection. Monitor and repair as necessary

3 - II. ELECTRICAL SYSTEMS

I NI NP D
3.1 A. Service Entrance and Panels X X
3.2 B. Branch Circuits, Connected Devices and Fixtures X X
A. Service Entrance and Panels: Main Panel Disconnect Rating
125 Amps
A. Service Entrance and Panels: Electrical Service
Underground
A. Service Entrance and Panels: Electric Panel Manufacturer
SIEMENS
A. Service Entrance and Panels: Panel Type
Circuit breakers
A. Service Entrance and Panels: Main Service Panel Location
Side of Home
A. Service Entrance and Panels: Sub Panel Location
Garage
A. Service Entrance and Panels: Comments

Main electrical panel and service entrance located on side of the home. Main entrance service wires are aluminum, with sub feeds service is underground. Ground wire noted. Panel is in sound condition and wired in a professional manner at time of inspection.

Sub panel located in the garage. Panel is in sound condition and wired in a professional manner at time of inspection.

Bonding conductors cannot be observed in finished buildings to determine the serviceability, continuity, or connecting fittings and clamps. While we may be able to identify missing Grounding and Bonding, we cannot affirm, nor do we warranty, that all pipes, either gas, including CSST, water, plumbing, metal flues, metal framing, appliances or similar conductive materials are bonded. 

B. Branch Circuits, Connected Devices and Fixtures: Comments

All working Bath GFCI outlets passed mechanical and electrical testing at time of inspection and reset.

All working Kitchen GFCI outlets passed mechanical and electrical testing at time of inspection and reset.

All working Garage & Exterior GFCI outlets passed mechanical and electrical testing at time of inspection and reset.

Smoke detector(s) responded to manual test. Detectors were located in standard locations, one in each bedroom and outside sleeping area.

Plugs, switches, junction box covers and light fixtures are typically not removed during the inspection. Disassembly of the electrical system is beyond the scope of a home inspection and may reveal defects that were not visible at the time of inspection.

The inspector shall inspect: The service line. The meter box. The main disconnect. And determine the rating of the service amperage. Panels, breakers and fuses. The service grounding and bonding. A representative sampling of switches, receptacles, light fixtures, AFCI receptacles and test all GFCI receptacles and GFCI circuit breakers observed and deemed to be GFCI's during the inspection. And report the presence of solid conductor aluminum branch circuit wiring if readily visible. And report on any GFCI-tested receptacles in which power is not present, polarity is incorrect, the receptacle is not grounded, is not secured to the wall, the cover is not in place, the ground fault circuit interrupter devices are not properly installed or do not operate properly, or evidence of arcing or excessive heat is present. The service entrance conductors and the condition of their sheathing. The ground fault circuit interrupters observed and deemed to be GFCI's during the inspection with a GFCI tester. And describe the amperage rating of the service. And report the absence of smoke detectors. Service entrance cables and report as in need of repair deficiencies in the integrity of the insulation, drip loop, or separation of conductors at weatherheads and clearances.


The inspector is not required to: Insert any tool, probe or device into the main panel, sub-panels, downstream panel, or electrical fixtures. Operate electrical systems that are shut down. Remove panel covers or dead front covers if not readily accessible. Operate over current protection devices. Operate non-accessible smoke detectors. Measure or determine the amperage or voltage of the main service if not visibly labeled. Inspect the alarm system and components. Inspect the ancillary wiring or remote control devices. Activate any electrical systems or branch circuits which are not energized. Operate overload devices. Inspect low voltage systems, electrical de-icing tapes, swimming pool wiring or any time-controlled devices. Verify the continuity of the connected service ground. Inspect private or emergency electrical supply sources, including but not limited to generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. Inspect spark or lightning arrestors. Conduct voltage drop calculations. Determine the accuracy of breaker labeling. Inspect exterior lighting.

  • I = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficient
Credit
Comment
3.1.1 - A. Service Entrance and Panels

Main Panel Breakers Not Labeled
Location: Main Panel On Side Of Home

A Circuit Directory identifying individual electrical circuits was missing, illegible or inaccurate at this panel. The panel should contain a clearly-marked label identifying individual circuits so that in an emergency, individual circuits can be quickly shut off.
Credit
Comment
3.2.1 - B. Branch Circuits, Connected Devices and Fixtures

No GFCI
Location: Laundry Room

No ground fault circuit interrupter (GFCI) protection of home electrical receptacles was provided in laundry room at the time of inspection. For safety reasons, current standards recommend  that electrical receptacles located within 6 feet of a plumbing fixture be provided with ground fault circuit interrupter (GFCI) protection in good working order to avoid potential electric shock or electrocution hazards by a qualified professional.

4 - III. HEATING, VENTILATION, AND AIR CONDITIONING SYSTEMS

I NI NP D
4.1 A. Heating Equipment X
4.2 B. Cooling Equipment X X
4.3 C. Duct Systems, Chases and Vents X
A. Heating Equipment: Type of Systems
Forced Air, Furnace
A. Heating Equipment: Energy Sources
Gas
A. Heating Equipment: Location
Hallway Closet
A. Heating Equipment: Air Filter Size
20X25X1
B. Cooling Equipment: Type of Systems
Central Air Conditioner
B. Cooling Equipment: Location
Side of Home
A. Heating Equipment: Furnace Info

Furnace Brand: CARRIER
Manufacture Date: JUN 2004
Model No: 58DLA110
Serial No: 2604A43417

A. Heating Equipment: Comment

I recommend that a qualified technician clean, evaluate and service furnace on a annual basis.

HVAC TREC DISCLAIMER - Note: Thermostats are checked in the manual mode only. Full evaluation of the integrity of a heat exchanger requires  dismantling of the furnace and is beyond the scope of this inspection.

B. Cooling Equipment: Air Conditioner Info

A/C Brand: CARRIER
Manufacture Date: MAR 2004
Model No: 38TXA060
Serial No: 1104E03836

B. Cooling Equipment: Delta T Measurement

A/C unit functional test has a return temp of 61 F and the supply has a temp of 40 F for a differential of 21 F.

A differential between 15 to 22 F is considered normal.

C. Duct Systems, Chases and Vents: Comment

In the opinion of the inspector there were no visible defects in the visible ducts or ducting system that appeared to require immediate repair at the time of the inspection. 

The inspector shall inspect: The heating system and describe the energy source and heating method using normal operating controls. And report as in need of repair electric furnaces which do not operate. And report if inspector deemed the furnace inaccessible. The central cooling equipment using normal operating controls. The fireplace, and open and close the damper door if readily accessible and operable. Hearth extensions and other permanently installed components. And report as in need of repair deficiencies in the lintel, hearth and material surrounding the fireplace, including clearance from combustible materials.


The inspector is not required to: Inspect or evaluate interiors of flues or chimneys, fire chambers, heat exchangers, humidifiers, dehumidifiers, electronic air filters, solar heating systems, solar heating systems or fuel tanks. Inspect underground fuel tanks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. Light or ignite pilot flames. Activate heating, heat pump systems, or other heating systems when ambient temperatures or when other circumstances are not conducive to safe operation or may damage the equipment. Override electronic thermostats. Evaluate fuel quality. Verify thermostat calibration, heat anticipation or automatic setbacks, timers, programs or clocks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. Inspect window units, through-wall units, or electronic air filters. Operate equipment or systems if exterior temperature is below 60 degrees Fahrenheit or when other circumstances are not conducive to safe operation or may damage the equipment. Inspect or determine thermostat calibration, heat anticipation or automatic setbacks or clocks. Examine electrical current, coolant fluids or gasses, or coolant leakage. Inspect the flue or vent system. Inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels. Determine the need for a chimney sweep. Operate gas fireplace inserts. Light pilot flames. Determine the appropriateness of such installation. Inspect automatic fuel feed devices. Inspect combustion and/or make-up air devices. Inspect heat distribution assists whether gravity controlled or fan assisted. Ignite or extinguish fires. Determine draft characteristics. Move fireplace inserts, stoves, or firebox contents. Determine adequacy of draft, perform a smoke test or dismantle or remove any component. Perform an NFPA inspection. Perform a Phase 1 fireplace and chimney inspection.

  • I = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficient
Credit
Comment
4.2.1 - B. Cooling Equipment

A/C Disconnect - Missing Panel Cover

The electrical panel that housed the air-conditioner disconnect was missing the front panel cover which is exposing the electrical wires. This is a safety concern that should be corrected by replacing the missing cover by a qualified professional. 

Credit
Comment
4.2.2 - B. Cooling Equipment

Condensation Line Insulation - Damaged

The insulation on the condensate line for the air conditioner was found to be damaged and or missing foam insulation. Tho should be corrected by replacing any missing or damaged insulation in the line to prevent condensation buildup.

5 - IV. PLUMBING SYSTEMS

I NI NP D
5.1 A. Plumbing Supply, Distribution System and Fixtures X X
5.2 B. Drains, Wastes and Vents X
5.3 C. Water Heating Equipment X
5.4 D. Hydro-Massage Therapy Equipment X
A. Plumbing Supply, Distribution System and Fixtures: Location of water meter
Curb In Front of Home
A. Plumbing Supply, Distribution System and Fixtures: Location of main water supply valve
Garage
C. Water Heating Equipment: Energy Sources
Gas
C. Water Heating Equipment: Capacity
N/A
C. Water Heating Equipment: Water Heater Location
Hallway Closet
A. Plumbing Supply, Distribution System and Fixtures: Static water pressure reading
45 psi

Normal is between 40 - 80 psi

C. Water Heating Equipment: Water Heater Info

Water Heater Brand: AO SMITH
Manufacture Date: N/A
Model No: N/A
Serial No: N/A

D. Hydro-Massage Therapy Equipment: Comments

Unit was tested and worked properly at the time of the inspection. Unit is GFCI protected. 

A. Plumbing Supply, Distribution System and Fixtures: Shutoff Valves - Not Operated

The main water shut-off valve and individual fixture shut-off valves were not operated at the time of inspection to avoid potential water damage from leakage. If the valve has not been operated recently, it may leak and need to be repaired. 

B. Drains, Wastes and Vents: Drain, Waste & Vent Pipes - Not Visible

No specialized testing was conducted on any plumbing system at the time of this inspection. Most drain, waste and vent pipes are typically not visible in a finished home. 

The inspector shall: Verify the presence of and identify the location of the main water shutoff valve. Inspect the water heating equipment, including combustion air, venting, connections, energy sources, seismic bracing, and verify the presence or absence of temperature-pressure relief valves and/or Watts 210 valves. Flush toilets. Run water in sinks, tubs, and showers. Inspect the interior water supply including all fixtures and faucets. Inspect the drain, waste and vent systems, including all fixtures. Describe any visible fuel storage systems. Inspect the drainage sump pumps testing sumps with accessible floats. Inspect and describe the water supply, drain, waste and main fuel shut-off valves, as well as the location of the water main and main fuel shut-off valves. Inspect and determine if the water supply is public or private. Inspect and report as in need of repair deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously. Inspect and report as in need of repair deficiencies in installation and identification of hot and cold faucets. Inspect and report as in need of repair mechanical drain-stops that are missing or do not operate if installed in sinks, lavatories and tubs. Inspect and report as in need of repair commodes that have cracks in the ceramic material, are improperly mounted on the floor, leak, or have tank components which do not operate.

The inspector is not required to: Light or ignite pilot flames. Determine the size, temperature, age, life expectancy or adequacy of the water heater. Inspect interiors of flues or chimneys, water softening or filtering systems, well pumps or tanks, safety or shut-of valves, floor drains, lawn sprinkler systems or fire sprinkler systems. Determine the exact flow rate, volume, pressure, temperature, or adequacy of the water supply. Determine the water quality or potability or the reliability of the water supply or source. Open sealed plumbing access panels. Inspect clothes washing machines or their connections. Operate any main, branch or fixture valve. Test shower pans, tub and shower surrounds or enclosures for leakage. Evaluate the compliance with local or state conservation or energy standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. Determine the effectiveness of anti-siphon, back-flow prevention or drain-stop devices. Determine whether there are sufficient clean-outs for effective cleaning of drains. Evaluate gas, liquid propane or oil storage tanks. Inspect any private sewage waste disposal system or component of. Inspect water treatment systems or water filters. Inspect water storage tanks, pressure pumps or bladder tanks. Evaluate time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. Evaluate or determine the adequacy of combustion air. Test, operate, open or close safety controls, manual stop valves and/or temperature or pressure relief valves. Examine ancillary systems or components, such as, but not limited to, those relating to solar water heating, hot water circulation.

  • I = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficient
Credit
Comment
5.1.1 - A. Plumbing Supply, Distribution System and Fixtures

Possible Water Line Leak

At the time of inspection I checked the water meter after all the water in the home had been turned off and the meter was still turning, indicating water was still flowing to the house due to a possible leak in a water supply line. I did observed a wet area around irrigation water line in the back of the home. I recommend further evaluation for a possible leak in the home by a licensed plumber . 

Credit
Comment
5.1.2 - A. Plumbing Supply, Distribution System and Fixtures

Hose Bib Backflow Preventer - Missing

Exterior hose bibs were found to be missing backflow preventer devices (vacuum breakers). Vacuum breakers are easy to install, inexpensive and should be in place on all exterior bibs (water hose faucets) to help prevent exterior water from getting siphoned into the homes water supply. Click here for more information

Credit
Comment
5.1.3 - A. Plumbing Supply, Distribution System and Fixtures

Leaking Shower Head
Location: Hallway Bathroom

The showerhead connection leaked when the shower was operated. 

6 - V. APPLIANCES

I NI NP D
6.1 A. Dishwasher X
6.2 B. Food Waste Disposers X
6.3 C. Range Hood and Exhaust System X
6.4 D. Ranges, Cooktops and Ovens X
6.5 E. Microwave Ovens X
6.6 F. Mechanical Exhaust Vents and bathroom Heaters X
6.7 G. Garage Door Operator(s) X
6.8 H. Dryer Exhaust System X
D. Ranges, Cooktops and Ovens: Range/Oven Manufacturer
FRIGIDAIRE
D. Ranges, Cooktops and Ovens: Energy Source
Electricity, Natural Gas
F. Mechanical Exhaust Vents and bathroom Heaters: Comments

All vents tested and worked correctly at time of inspection. 

G. Garage Door Operator(s): Auto-opener Manufacturer
CHAMBERLAIN
H. Dryer Exhaust System: Comments

At time of inspection, there were no deficient items observed. 

E. Microwave Ovens: Built in Microwave Manufacturer
FRIGIDAIRE
A. Dishwasher: Dishwasher Brand
KITCHEN AID
A. Dishwasher: Comments

Dishwasher was tested for a full cycle, in normal mode, and appears to be functioning normally at time of inspection. 

B. Food Waste Disposers: Comments

Garbage disposal was tested and appears to be functional at time of inspection. 

C. Range Hood and Exhaust System: Exhaust / Range Hood

Range hood was tested and appears to be functioning normally at the time of the inspection. Vented to the outside. 

D. Ranges, Cooktops and Ovens: Type
Oven, Cooktop
D. Ranges, Cooktops and Ovens: Oven Tested

Oven tested at 350 degrees F. Actual Temp measured: 351 degrees F. (+/- 25 F allowed
difference) is acceptable.

E. Microwave Ovens: Comments

Microwave was tested for one minute and appears to be functioning correctly at time of inspection.

G. Garage Door Operator(s): Comments

Automatic Garage Door opener was tested and operates normally. Photo-electric sensors and auto reverse feature worked as intended and passed safety test. 

H. Dryer Exhaust System: Maintenance Tip

It is typically recommended to have the dryer exhaust ducts cleaned of lint before installing the new dryer and at least once a year. Accumulated lint can be a fire hazard.

The home inspector shall observe and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable.

  • I = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficient