1234 Main St.
Azusa, ca 91702
04/03/2020 9:00AM

Sample agent
agent

Agent Name

Agency Name
5
Maintenance item
20
Recommendation
3
Safety hazard

1 - Inspection Details

In Attendance
Client, Client's Agent
Occupancy
Vacant
Temperature (approximate)
80 Fahrenheit (F)
Type of Building
Single Family
Weather Conditions
Clear

2 - Roof

IN NI NP D
2.1 Coverings X
2.2 Roof Drainage Systems X X
2.3 Flashings X X
2.4 Skylights, Chimneys & Other Roof Penetrations X X
Inspection Method
Walked roof
Roof Type/Style
Gable
Roof Drainage Systems: Gutter Material
Aluminum
Flashings: Material
Aluminum
Coverings: Material
Asphalt

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
2.2.1 - Roof Drainage Systems

Debris

Debris has accumulated in the gutters. Recommend cleaning to facilitate water flow.

Here is a DIY resource for cleaning your gutters. 

$
Credit
Comment
2.3.1 - Flashings

Corroded - Minor

Roof flashing showed signs of corrosion, but are still in working condition. Flashing should be monitored to prevent severe corrosion leading to moisture intrusion. 

$
Credit
Comment
2.4.1 - Skylights, Chimneys & Other Roof Penetrations

Chimney Cap Missing

No chimney cap was observed. This is important to protect from moisture intrusion and protect the chimney. Recommend a qualified roofer or chimney expert install.

3 - Exterior

IN NI NP D
3.1 Siding, Flashing & Trim X X
3.2 Exterior Doors X X
3.3 Walkways, Patios & Driveways X X
3.4 Eaves, Soffits & Fascia X X
3.5 Vegetation, Grading, Drainage & Retaining Walls X X
Inspection Method
Visual
Siding, Flashing & Trim: Siding Material
Stucco, Wood
Exterior Doors: Exterior Entry Door
Steel
Walkways, Patios & Driveways: Driveway Material
Concrete

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
3.1.1 - Siding, Flashing & Trim

Evidence of Water Intrusion

Siding showed signs of water intrusion. This could lead to further siding deterioration and/or mold. Recommend a qualified siding contractor evaluate and repair. 

$
Credit
Comment
3.2.1 - Exterior Doors

Door does not seal

Exterior door does not seal properly allowing the elements or animals to get inside recommend further evaluation by qualified carpenter

Hammer Carpentry Contractor
$
Credit
Comment
3.4.1 - Eaves, Soffits & Fascia

Fascia - Rotted

One or more sections of the fascia are rotted. Recommend qualified roofer evaluate & repair.
$
Credit
Comment
3.4.2 - Eaves, Soffits & Fascia

Paint/Finish Failing

The paint or finish is failing. This can lead to deterioration and rot of the material. Recommend that the areas be properly prepared and painted / finished.

$
Credit
Comment
3.5.1 - Vegetation, Grading, Drainage & Retaining Walls

Brick loose or cracking

Brick is loose or cracking in more the one place in the back yard. Repair maybe needed, recommend monitoring of these areas 

Contractor Qualified Professional
$
Credit
Comment
3.5.2 - Vegetation, Grading, Drainage & Retaining Walls

Vegetation affecting planter wall

vegetation roots are putting pressure on planter wall and could affect the block wall in the future. Recommend monitoring to prevent future damage 

Contractor Qualified Professional

4 - Doors, Windows & Interior

IN NI NP D
4.1 Doors X X
4.2 Windows X X
4.3 Floors X
4.4 Walls X
4.5 Ceilings X
4.6 Steps, Stairways & Railings X
4.7 Countertops & Cabinets X X
Windows: Window Manufacturer
Unknown
Windows: Window Type
Sliders
Floors: Floor Coverings
Carpet, Engineered Wood
Walls: Wall Material
Drywall
Ceilings: Ceiling Material
drywall
Countertops & Cabinets: Cabinetry
Wood
Countertops & Cabinets: Countertop Material
Composite

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
4.1.1 - Doors

Doorbell was inoperable

Doorbell was inoperable. Recommend to repair of replace  

Contractor Qualified Professional
$
Credit
Comment
4.2.1 - Windows

Damaged screen

Damaged screen in window to the left of the front door and also in the bedroom next to the laundry . Recommend replacement. 

Contractor Qualified Professional
$
Credit
Comment
4.7.1 - Countertops & Cabinets

Staining in cabinet

Staining was observed in the cabinet during the inspection could be a result form a leak that has been repaired in the past. No active leak was found. 

Contractor Qualified Professional

5 - Heating

IN NI NP D
5.1 Equipment X
5.2 Normal Operating Controls X
5.3 Distribution Systems X
5.4 Presence of Installed Heat Source in Each Room X
Equipment: Energy Source
Gas
Equipment: Heat Type
Forced Air
Distribution Systems: Ductwork
Insulated
Equipment: Brand
Rheem

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

6 - Plumbing

IN NI NP D
6.1 Main Water Shut-off Device X X
6.2 Drain, Waste, & Vent Systems X X
6.3 Water Supply, Distribution Systems & Fixtures X X
6.4 Hot Water Systems, Controls, Flues & Vents X X
6.5 Fuel Storage & Distribution Systems X
6.6 Sump Pump X
Filters
None
Water Source
Public
Drain, Waste, & Vent Systems: Drain Size
2"
Drain, Waste, & Vent Systems: Material
ABS
Water Supply, Distribution Systems & Fixtures: Distribution Material
Galvanized
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Copper, Galvanized
Hot Water Systems, Controls, Flues & Vents: Location
Garage
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Gas
Main Water Shut-off Device: Location
Left side behind garage
Hot Water Systems, Controls, Flues & Vents: Capacity
50 gallons
Hot Water Systems, Controls, Flues & Vents: Manufacturer
GE

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
6.1.1 - Main Water Shut-off Device

Corrosion

Water main shut-off shows signs of corrosion. Recommend a qualified plumber evaluate.

$
Credit
Comment
6.2.1 - Drain, Waste, & Vent Systems

Loose drain cap

Drain cover in master shower was loose and could cause injury. Recommended to repair or replace drain cover.

Contractor Qualified Professional
$
Credit
Comment
6.3.1 - Water Supply, Distribution Systems & Fixtures

Distribution Pipe Leaking

Distribution pipe was leaking. Recommend a qualified plumber evaluate and repair.
$
Credit
Comment
6.3.2 - Water Supply, Distribution Systems & Fixtures

Leaking hose bib

Three leaking hose bibs were noted around the property. Recommend replacement.

Contractor Qualified Professional
$
Credit
Comment
6.3.3 - Water Supply, Distribution Systems & Fixtures

Leaking shower head

Shower head in master bathroom was leaking when shower was turned on. Recommend replacement 

Contractor Qualified Professional
$
Credit
Comment
6.3.4 - Water Supply, Distribution Systems & Fixtures

cracks in tub

Cracks were observed near the tub in the guest hallway bathroom, this can cause water damage if not properly sealed 

Contractor Qualified Professional
$
Credit
Comment
6.4.1 - Hot Water Systems, Controls, Flues & Vents

Near End of Life

Water heater showed normal signs of wear and tear. Recommend monitoring it's effectiveness and replacing in the near future.
$
Credit
Comment
6.4.2 - Hot Water Systems, Controls, Flues & Vents

No Drip Pan

No drip pan was present. Recommend installation by a qualified plumber.
$
Credit
Comment
6.4.3 - Hot Water Systems, Controls, Flues & Vents

Water Stains - Leakage

Water stains were observed beneath water heater, indicating a past or present leak. Recommend further evaluation and repair by a qualified plumber.
$
Credit
Comment
6.4.4 - Hot Water Systems, Controls, Flues & Vents

Water heater vent

Water heater vent was loose at time of inspection it is recommend to have the vent fastened securely. 

Contractor Qualified Professional

7 - Cooling

IN NI NP D
7.1 Cooling Equipment X
7.2 Normal Operating Controls X
7.3 Distribution System X
7.4 Presence of Installed Cooling Source in Each Room X
Cooling Equipment: Energy Source/Type
Electric, Central Air Conditioner
Cooling Equipment: Location
Roof
Distribution System: Configuration
Central
Cooling Equipment: Brand
Rheem

I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

8 - Electrical

IN NI NP D
8.1 Main & Subpanels, Service & Grounding, Main Overcurrent Device X X
8.2 Branch Wiring Circuits, Breakers & Fuses X X
8.3 Lighting Fixtures, Switches & Receptacles X X
8.4 GFCI & AFCI X
8.5 Smoke Detectors X
8.6 Carbon Monoxide Detectors X
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Capacity
100 AMP
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Manufacturer
General Electric
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Type
Circuit Breaker
Branch Wiring Circuits, Breakers & Fuses: Branch Wire 15 and 20 AMP
Copper
Branch Wiring Circuits, Breakers & Fuses: Wiring Method
Romex
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main Panel Location
Right, Back
Smoke Detectors: Smoke detector

Smoke detectors was tested and worked properly at the time of inspection.

Carbon Monoxide Detectors: Carbon Monoxide

Carbon Monoxide detectors were tested and worked properly at time of inspection.

branch wiring limitations

Home branch circuit wiring consists of wiring distributing electricity to devices such as switches, receptacles, and appliances. Most conductors are hidden behind floor, wall and ceiling coverings and cannot be evaluated by the inspector. The Inspector does not remove cover plates and inspection of branch wiring is limited to proper response to testing of switches and a representative number of electrical receptacles.

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
8.1.1 - Main & Subpanels, Service & Grounding, Main Overcurrent Device

Double tap

Double tapped wires were observed at two breakers at time of inspection. Double tap is when two wires are connected to one breaker this can cause arcing if the wires get loose and is a fire hazard. Recommend further evaluation from a licensed contractor.

Electric Electrical Contractor
$
Credit
Comment
8.1.2 - Main & Subpanels, Service & Grounding, Main Overcurrent Device

Service Panel hinge missing

Service panel hinge missing. recommend replacing with new hinge 

Contractor Qualified Professional
$
Credit
Comment
8.2.1 - Branch Wiring Circuits, Breakers & Fuses

Open junction box

Open junction boxes were observed in the attic during the inspection this is a saftey hazard and should be covered. Recommend further evaluation from a licensed electrician. 

Electric Electrical Contractor
$
Credit
Comment
8.3.1 - Lighting Fixtures, Switches & Receptacles

Cover Plates Missing

Receptacle in the garage was missing a cover plate. This causes short and shock risk. Recommend installation of plates.

9 - Fireplace

IN NI NP D
9.1 Vents, Flues & Chimneys X
9.2 Lintels X
9.3 Damper Doors X
9.4 Cleanout Doors & Frames X
Type
Wood, Gas

I. The inspector shall inspect:

readily accessible and visible portions of the fireplaces and chimneys;

lintels above the fireplace openings;

damper doors by opening and closing them, if readily accessible and manually operable; and

cleanout doors and frames.

II. The inspector shall describe:

the type of fireplace.

III. The inspector shall report as in need of correction:

evidence of joint separation, damage or deterioration of the hearth, hearth extension or chambers;

manually operated dampers that did not open and close;

the lack of a smoke detector in the same room as the fireplace;

the lack of a carbon-monoxide detector in the same room as the fireplace; and

cleanouts not made of metal, pre-cast cement, or other non-combustible material.

IV. The inspector is not required to:

inspect the flue or vent system.

inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels.

determine the need for a chimney sweep.

operate gas fireplace inserts.

light pilot flames.

determine the appropriateness of any installation.

inspect automatic fuel-fed devices.

inspect combustion and/or make-up air devices.

inspect heat-distribution assists, whether gravity-controlled or fan-assisted.

ignite or extinguish fires.

determine the adequacy of drafts or draft characteristics.

move fireplace inserts, stoves or firebox contents.

perform a smoke test.

dismantle or remove any component.

perform a National Fire Protection Association (NFPA)-style inspection.

perform a Phase I fireplace and chimney inspection.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

10 - Attic, Insulation & Ventilation

IN NI NP D
10.1 Attic Insulation X
10.2 Vapor Retarders (Crawlspace or Basement) X
10.3 Ventilation X
10.4 Exhaust Systems X
Dryer Power Source
110 Volt
Dryer Vent
Metal (Flex)
Ventilation: Ventilation Type
Gable Vents, Soffit Vents
Exhaust Systems: Exhaust Fans
Fan Only
Attic Insulation: Insulation Type
Blown, Cellulose
Attic limitations

The following items or areas are not included in this inspection-areas that could not be traversed or viewed clearly due to lack of access, areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.

Vapor Retarders (Crawlspace or Basement) not present.

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

11 - Basement, Foundation, Crawlspace & Structure

IN NI NP D
11.1 Foundation X
11.2 Basements & Crawlspaces X
11.3 Floor Structure X
11.4 Wall Structure X
11.5 Ceiling Structure X
Inspection Method
Visual
Foundation: Material
Concrete, Slab on Grade
Floor Structure: Basement/Crawlspace Floor
Concrete
Floor Structure: Material
Concrete
Slab Foundation

The home was slab on grade and finished construction. Therefore the majority of the slab, except for the exterior section along the grounds, was not visible and not inspected. The Inspector disclaims any latent defects with the foundation as a result.

Structure

The General Home Inspection includes inspection of the home structural elements that were readily visible at the time of the inspection. This typically includes the foundation, exterior walls, floor structures and roof structure. Much of the home structure is hidden behind exterior and interior roof, floor, wall, and ceiling coverings, or is buried underground. Because the General Home Inspection is limited to visual and non-invasive methods, this report may not identify all structural deficiencies. Upon observing indications that structural problems may exist that are not readily visible, the inspector may recommend inspection, testing, or evaluation by a specialist that may include invasive measures.

Basements & Crawlspaces not present.

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

12 - Built-in Appliances

IN NI NP D
12.1 Dishwasher X
12.2 Refrigerator X X
12.3 Range/Oven/Cooktop X
12.4 Garbage Disposal X
Dishwasher: Brand
GE
Refrigerator: Brand
GE
Range/Oven/Cooktop: Exhaust Hood Type
Vented
Range/Oven/Cooktop: Range/Oven Brand
Unknown
Range/Oven/Cooktop: Range/Oven Energy Source
Electric
appliances
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
12.2.1 - Refrigerator

Ice dispenser inoperable

Ice and water dispenser were inoperable at time of inspection. Recommend further evaluation from licensed plumber

Pipes Plumbing Contractor

13 - Garage

IN NI NP D
13.1 Ceiling X
13.2 Floor X
13.3 Walls & Firewalls X
13.4 Garage Door X X
13.5 Garage Door Opener X X
13.6 Occupant Door (From garage to inside of home) X
Garage Door: Material
Metal
Garage Door: Type
Sliding
Garage
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
13.4.1 - Garage Door

Motor power supply

Garage door motor was connected to an extension cord and plugged into the wall, this in not recommended for long term use. Garage motors should be connected directly to an electric reciprocal. 

Contractor Qualified Professional