Viewing:

1234 Main St.
Normal, IL 61761
01/19/2020 9:00AM

Sample agent
agent

Agent Name

Agency Name
4
Maintenance item
11
Recommendation
4
Safety hazard

1 - Inspection Details

In Attendance
Homeowner Provided Access, Inspector, Client last 30 min
Occupancy
Occupied
Style
2 Story
Temperature (approximate)
46 Fahrenheit (F)
Type of Building
Single Family
Weather Conditions
Cloudy
Cold Temperature Limitations Below 65

Temperatures below 65 degrees: AC units are not tested when exterior temperatures are below 60 degrees. AC units could be damaged during these temperatures.

2 - Roof

IN NI NP D
2.1 Coverings X
2.2 Roof Drainage Systems X
2.3 Flashings X
2.4 Skylights, Chimneys & Other Roof Penetrations X
Roof Type/Style
Gable
Inspection Method
2nd Story Windows, Quadcopter, Ground

We observe the roof using safe observation methods. When roof surfaces appear deteriorated, slippery, or wet, we may not walk the roof surface. Binoculars, quadcopter, cameras with zoom lenses may be used if we do not walk the roof surface. 

Coverings: Material
Asphalt, Rubber Membrane

Roof covering appeared in good overall condition at the time of inspection. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Roof Drainage Systems: Gutter Material
Aluminum, Gutter Guards

Recommend cleaning the gutter system regularly to prevent clogging and allowing rain runoff to drain where intended away from the foundation. Clogged gutters could cause damage to roof, fascia, and soffit over time if rain runoff does not go down the downspouts and away.  Recommend sealing any leaking seams or corners. Monitor to assure gutters stay attached especially if debris, ice, or snow builds up in them. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Flashings: Material
Metal

Visible flashings were in good overall condition during the inspection. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
2.4.1 - Skylights, Chimneys & Other Roof Penetrations

Chimney Cap Cracked

Chimney Cap showed signs of cracking and deterioration. Recommend evaluation and repair by qualified chimney contractor.

Fireplace Chimney Repair Contractor
$
Credit
Comment
2.4.2 - Skylights, Chimneys & Other Roof Penetrations

Recommend Adding a Rain Cap and Squirrel Guard

Recommend adding a chimney rain cap and squirrel guard to prevent moisture and pests from entering the flue.

Contractor Qualified Professional

3 - Attic, Insulation & Ventilation

IN NI NP D
3.1 Roof Structure & Attic X
3.2 Insulation X
3.3 Ventilation X
3.4 Exhaust Systems X
Roof Structure & Attic: Roof Structure Material
Rafters
Roof Structure & Attic: Type
Gable
Insulation: Flooring Insulation
Missing, Foam
Ventilation: Dryer Power Source
Not Visible
Ventilation: Ventilation Type
Ridge Vents
Ventilation: Dryer Vent
Metal (Flex)
Roof Structure & Attic: General Photos

Visible Roof Structure and Attic Components appeared in good overall condition at the time of inspection. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Insulation: Attic Insulation Type
Fiberglass, Blown

Common building practices change over time. The amount and style of insulation installed in the home may have met the requirements during the time of construction. Over time insulation can settle or become compressed and may require additional insulation for added efficiency. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Exhaust Systems: Exhaust Fans
Fan with Light

Modern building practices recommend Bathroom Exhaust Fans to be vented to the exterior of the home. Many homes were built prior to the requirement of venting these fans to the exterior and may still discharge into the attic space. Bathroom vents discharging into attic areas or basements/crawl spaces with not enough ventilation may cause elevated moisture levels resulting in organic growth in attic spaces or basement areas. 

Any defects, recommendations,  or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
3.1.1 - Roof Structure & Attic

Open electrical box / Open Electrical Junction

Recommend enclosing electrical junctions inside an enclosed electrical box for added safety.


Boxes in the attic that were newer appeared to be unfinished. No power was present in these boxes during the inspection.

Electric Electrical Contractor
$
Credit
Comment
3.2.1 - Insulation

Consider Adding Additional Insulation
Basement,Attic

Consider adding additional insulation for added efficiency.

Contractor Qualified Professional

4 - Exterior

IN NI NP D
4.1 Siding, Flashing & Trim X
4.2 Exterior Windows X
4.3 Exterior Doors X
4.4 Walkways, Patios & Driveways X
4.5 Decks, Balconies, Porches & Steps X
4.6 Eaves, Soffits & Fascia X
4.7 Vegetation, Grading, Drainage & Retaining Walls X
Inspection Method
Visual
Siding, Flashing & Trim: Siding Style
Beveled
Walkways, Patios & Driveways: Driveway Material
Asphalt, Concrete
Siding, Flashing & Trim: Siding Material
Vinyl

Exterior wall coverings appeared in good general condition during the inspection. Recommend regular painting of exterior wood surfaces and refreshing caulking around windows and doors as needed for proper maintenance. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Exterior Windows: General Information

Exterior Windows appeared in good overall condition and operated successfully at the time of inspection. Recommend regular painting of wood window frames as regular maintenance. Recommend monitoring sealant around the windows and caulk as needed. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection.

Exterior Doors: Exterior Entry Door
Steel, Wood

Exterior doors appeared in good overall condition and operated successfully at the time of inspection. Recommend regular painting of wood door frames as regular maintenance. Recommend monitoring sealant around the doors and caulk as needed. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Walkways, Patios & Driveways: Walkways, and Driveways

Walkways and Driveways appeared in good overall condition at the time of inspection. Recommend monitoring for settling and repairing as needed. Common building practices recommend leveling surfaces with cracks raised more than 3/4 of an inch. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Decks, Balconies, Porches & Steps: Appurtenance
Covered Porch
Decks, Balconies, Porches & Steps: Deck/Patio Material
Wood

Decks/Patio appeared in good general condition at the time of inspection. Recommend monitoring for future sealant application for proper maintenance. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Vegetation, Grading, Drainage & Retaining Walls: Proper Grading

Recommend monitoring soil around the foundation to ensure proper drainage going away from the foundation to prevent moisture intrusion. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
4.4.1 - Walkways, Patios & Driveways

Walkway Cracking - Minor

Minor cosmetic cracks observed. Recommend monitor and/or patch/seal.

5 - Basement, Foundation, Crawlspace & Structure

IN NI NP D
5.1 Foundation X
5.2 Vapor Retarders (Crawlspace or Basement) X
5.3 Basements & Crawlspaces X
5.4 Floor Structure X
5.5 Wall Structure X
5.6 Ceiling Structure X
Inspection Method
Visual
Floor Structure: Basement/Crawlspace Floor
Concrete
Foundation: Material
Brick

Visible Foundation Areas appeared in good overall condition. Monitor foundation areas for leaking or water seepage after heavy rains and repair as needed. Some foundation styles like Brick or Block foundations experience minor leaking more often than Poured Concrete. Monitor for changes in the foundation such as cracking/movement/bowing and repair as needed. 

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Basements & Crawlspaces: General Photos

Visible Basement/Crawlspace area appeared in good overall condition at the time of inspection. Monitor for elevated moisture. Consider installing a dehumidifier for the humid times of year to pull out excess moisture. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Floor Structure: Floor Structure Material
Wood Floor Joist

Visible floor joists appeared in good overall condition. Monitor for future damage and repair as needed.

Floor Structure: Sub-floor
Plank

Visible Sub-floor appeared in good overall condition during the inspection. Monitor for future damage and repair as needed.

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
5.1.1 - Foundation

Budget for Tuck Pointing
Rear corner next to deck

Recommend budget for tuck pointing the brick. This is common maintenance for brick foundations when the mortar between the joints begin to deteriorate over time. 


The rear corner behind the deck appeared to have deteriorated and had falling bricks. Recommend evaluation and repair by masonry contractor.

Contractor Qualified Professional
$
Credit
Comment
5.3.1 - Basements & Crawlspaces

Efflorescence

Efflorescence noted on the foundation wall surface. This a white, powdery deposit that is consistent with minor moisture intrusion. Recommend adding soil to low spots around the foundation, keeping downspout extensions on, and gutters clean to prevent high levels of moisture near the foundation. Consider sealing the foundation wall to help prevent further moisture intrusion. 

$
Credit
Comment
5.3.2 - Basements & Crawlspaces

Tuck Pointing

Several areas in the foundation wall showed signs of future tuckpointing required. This is common maintenance for brick foundations of this period. Recommend budgeting for tuck pointing. 

Contractor Qualified Professional

6 - Heating

IN NI NP D
6.1 Equipment X
6.2 Normal Operating Controls X
6.3 Distribution Systems X
6.4 Presence of Installed Heat Source in Each Room X
Equipment: Energy Source
Natural Gas
Equipment: Year Manufactured (Estimated)
2002
Equipment: Heat Type
Forced Air
Distribution Systems: Ductwork
Non-insulated
Equipment: Brand
Carrier

Heating system appeared to operate successfully at the time of inspection. Recommend maintaining the heating system regularly to keep the unit operating effectively.

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
6.3.1 - Distribution Systems

Possible Asbestos Tape

Possible asbestos tape was noted on several duct joints in the HVAC Distribution system. Consider further testing to determine if the material is asbestos and remediate as needed.

Contractor Qualified Professional

7 - Cooling

IN NI NP D
7.1 Cooling Equipment X
7.2 Normal Operating Controls X
7.3 Distribution System X
7.4 Presence of Installed Cooling Source in Each Room X
Cooling Equipment: Year Manufactured
1991
Cooling Equipment: Energy Source/Type
Electric
Cooling Equipment: Location
Exterior East
Distribution System: Configuration
Split
Cooling Equipment: Brand
Lennox

Cooling system appeared to operate successfully at the time of inspection. Recommend maintaining the cooling system regularly to keep the unit operating effectively.

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Cooling Equipment: Low Temperature
The A/C unit was not tested due to low outdoor temperature. This may cause damage the unit.

I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency

8 - Electrical

IN NI NP D
8.1 Service Entrance Conductors X
8.2 Main & Subpanels, Service & Grounding, Main Overcurrent Device X
8.3 Branch Wiring Circuits, Breakers & Fuses X
8.4 Lighting Fixtures, Switches & Receptacles X
8.5 GFCI & AFCI X
8.6 Smoke Detectors X
8.7 Carbon Monoxide Detectors X
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Branch Wire 15 and 20 AMP
Copper
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Capacity
200 AMP
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Wiring Method
Not Visible, Romex, Conduit
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Manufacturer
Square D
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Type
Circuit Breaker
Accessible Electrical Systems Appeared To Operate Successfully

Accessible Electrical Systems (light fixtures, receptacles, electrical panels & sub-panels) appeared to operate successfully. Any defects, limitations, or deficiencies will be noted in the Summary. 

Service Entrance Conductors: Electrical Service Conductors
Overhead
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main Panel Location
Basement, Workshop
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Sub Panel Location
Garage
GFCI & AFCI: General Note on GFCI Protection

Any outlet within 6 ft of a water source should be GFCI protected for added safety. Common locations include: Near kitchen sink, bathroom sinks, laundry sinks, basement outlets, garage outlets, and exterior outlets. Regular testing of the units to confirm successful operation is recommended. Some homes built before GFCI requirements may not have GFCI Protection if the home has not been updated. 

Years when GFCI Protection became a requirement and its location:

Smoke Detectors: Smoke Detector General Information

Recommend replacement of smoke detectors based on manufacturer warranty and recommendation. Common age required for replacement is 5-7 years old. Smoke detectors should be installed on each floor and near sleeping areas for added safety. Recommend regular testing and changing of accessible batteries for proper operation.

Carbon Monoxide Detectors: Carbon Monoxide Detectors General Information

Carbon Monoxide detectors should be installed within 15 feet of any sleeping area for added safety. Older units should be replaced based on manufacturer warranty schedule. Common timeframe for replacement is 7 years old. Recommend regular testing to confirm successful operation. Recommend changing batteries regularly for added safety.

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
8.3.1 - Branch Wiring Circuits, Breakers & Fuses

3 Prong Ungrounded Outlets

Several outlets in the home appeared to have 3 prongs with an open ground. Several conditions could exist allowing this to happen. 1) The home was built before it was common to install grounded branch wiring. 2) The installed failed to attach ground conductor to the outlet. 3) The main electrical panel was insufficiently grounded. Recommend evaluation and repair by qualified electrician for added safety.

Electric Electrical Contractor
$
Credit
Comment
8.4.1 - Lighting Fixtures, Switches & Receptacles

Light Switch Failed to Operate Successfully
Laundry Room Light, Failed to turn off

One or more light switches failed to operate successfully. Recommend evaluation and repair by qualified electrical contractor for added safety and proper operation.

Electric Electrical Contractor
$
Credit
Comment
8.5.1 - GFCI & AFCI

No GFCI Protection at Exterior Outlet

Recommend installing GFCI protection for exterior outlets for added safety.

Electric Electrical Contractor
$
Credit
Comment
8.6.1 - Smoke Detectors

Defective

Smoke detector is connected, but not functioning properly. Recommend replacement.
$
Credit
Comment
8.7.1 - Carbon Monoxide Detectors

No Carbon Monoxide Detector Near Bedrooms

Recommend installing a carbon monoxide detector within 15ft of any sleeping area for added safety.

9 - Plumbing

IN NI NP D
9.1 Main Water Shut-off Device X
9.2 Drain, Waste, & Vent Systems X
9.3 Water Supply, Distribution Systems & Fixtures X
9.4 Hot Water Systems, Controls, Flues & Vents X
9.5 Fuel Storage & Distribution Systems X
9.6 Sump Pump X
Filters
None
Water Source
Public
Main Water Shut-off Device: Water Supply Material
Lead
Main Water Shut-off Device: Distribution Material
Copper
Drain, Waste, & Vent Systems: Washer Drain Size
2"
Hot Water Systems, Controls, Flues & Vents: Age (Estimated)
2007 Year Manufactured
Hot Water Systems, Controls, Flues & Vents: Capacity
50 gallons
Hot Water Systems, Controls, Flues & Vents: Location
Basement
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Electric
Sump Pump: Location
No Sump Pump was located during inspection
Sump Pump: Sump Pump Lid
NA
Main Water Shut-off Device: Location
Basement, Near Furnace

Monitor for corrosion or leaking and repair as needed. 

Fuel Storage & Distribution Systems: Main Gas Shut-off Location
Gas Meter
Drain, Waste, & Vent Systems: Main Waste Drain Material
Iron, PVC

Drain systems appeared to operate successfully at the time of inspection. Monitor for future leaking, corrosion, or failure and repair as needed. 

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

Drain, Waste, & Vent Systems: Sewer Scope Inspection

Consider further sewer inspection to determine condition of the sewer from the house to the city sewer connection. Our inspection includes a flow test to help determine leaks and slow drains inside the home. Older homes in established neighborhoods with large trees may develop tree roots in the sewer lines causing potential sewer issues. Vacant homes may not display a sewer issue during an inspection, but after occupants move in and begin using laundry machines, dishwasher, and normal family usage, clogged sewer lines will show signs of trouble within a week or two after occupants move in. 

Water Supply, Distribution Systems & Fixtures: General plumbing photos

Accessible faucets appeared to operate successfully at the time of inspection. Monitor for future leaking, slow drains, or corrosion and repair as needed.

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection.

Hot Water Systems, Controls, Flues & Vents: Manufacturer
Whirlpool

Hot Water System appeared to operate successfully at the time of inspection. Recommend monitoring the plumbing connections for corrosion or leaking and repair as needed. Recommend maintaining the unit per manufacturer recommendations to keep the unit operating as intended.

Consider Radon Testing

Consider radon testing to determine indoor air quality. Radon gas has been proven to cause lung cancer. Homes with living spaces in the lower levels or above crawl spaces where significant time will be spent should be evaluated. 

Radon Mitigation System
Appeared to Operate Successfully

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
9.1.1 - Main Water Shut-off Device

Lead Water Supply

The supply line delivering water to the house appeared to be made of lead. This is an older material commonly used in older homes. 


Consider proper filtration system for drinking water to limit exposure to lead. Consider upgrading the material to a more modern option. 

Pipes Plumbing Contractor
$
Credit
Comment
9.5.1 - Fuel Storage & Distribution Systems

Minor Gas Leak

Minor Gas leak noted in one or more locations during the inspection. Recommend evaluation and repair by qualified contractor.

Contractor Qualified Professional

10 - Doors, Windows & Interior

IN NI NP D
10.1 Ceilings X
10.2 Walls X
10.3 Floors X
10.4 Windows X
10.5 Doors X
10.6 Steps, Stairways & Railings X
10.7 Countertops & Cabinets X
Ceilings: Ceiling Material
Drywall, Plaster
Floors: Floor Coverings
Carpet, Hardwood, Tile
Windows: Window Manufacturer
Vinyl Frame windows
Windows: Window Type
Thermal
Countertops & Cabinets: Cabinetry
Wood
Countertops & Cabinets: Countertop Material
Granite
General Interior Photos

Home appeared in good overall condition at the time of inspection. 

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection.

Doors, Windows

Accessible Interior Doors, Accessible Interior Windows appeared to operate successfully at the time of inspection. Any defects will be noted in the Summary.

Walls: Wall Material
Plaster, Drywall

Walls appeared in good overall condition at the time of inspection. Small nail holes, or minor cosmetic concerns not related to structure or defects may not be listed as a concern. 

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
10.1.1 - Ceilings

Minor Damage

Minor damage or deterioration to the ceiling was visible at the time of the inspection.

$
Credit
Comment
10.5.1 - Doors

Door Doesn't Latch

Door doesn't latch properly. Recommend handyman repair latch and/or strike plate.

11 - Built-in Appliances

IN NI NP D
11.1 Dishwasher X
11.2 Refrigerator X
11.3 Range/Oven/Cooktop X
11.4 Garbage Disposal X
11.5 Built-in Microwave X
11.6 Range Hood Vent X
Dishwasher: Brand
Bosch
Range/Oven/Cooktop: Exhaust Hood Type
Vented
Range/Oven/Cooktop: Range/Oven Brand
GE
Range/Oven/Cooktop: Range/Oven Energy Source
Gas
Refrigerator: Brand
Frigidaire
Testing Appliances

During an inspection, accessible appliances are tested. Appliances which are not tested will be indicated on the Summary. Unfortunately we are unable to determine the effectiveness of an appliance or its ability to complete its designed task. We do note odd sounds, leaks, or the inability to operate based on observations during the inspection. 

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
11.1.1 - Dishwasher

Improper Installation

Upper brackets were not secured causing the unit to move around in the opening. Did not appear to cause any issues with the functionality of the unit.

12 - Fireplace

IN NI NP D
12.1 Vents, Flues & Chimneys X
12.2 Lintels X
12.3 Damper Doors X
12.4 Cleanout Doors & Frames X
Type
Wood, Inoperable
Wood Burning Fireplaces

Recommend chimney sweeping and inspection prior to using the wood burning fireplace by qualified chimney sweep. Our inspection is limited to the firebox, and a short distance up the visible flue. 

I. The inspector shall inspect:

readily accessible and visible portions of the fireplaces and chimneys;

lintels above the fireplace openings;

damper doors by opening and closing them, if readily accessible and manually operable; and

cleanout doors and frames.

II. The inspector shall describe:

the type of fireplace.

III. The inspector shall report as in need of correction:

evidence of joint separation, damage or deterioration of the hearth, hearth extension or chambers;

manually operated dampers that did not open and close;

the lack of a smoke detector in the same room as the fireplace;

the lack of a carbon-monoxide detector in the same room as the fireplace; and

cleanouts not made of metal, pre-cast cement, or other non-combustible material.

IV. The inspector is not required to:

inspect the flue or vent system.

inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels.

determine the need for a chimney sweep.

operate gas fireplace inserts.

light pilot flames.

determine the appropriateness of any installation.

inspect automatic fuel-fed devices.

inspect combustion and/or make-up air devices.

inspect heat-distribution assists, whether gravity-controlled or fan-assisted.

ignite or extinguish fires.

determine the adequacy of drafts or draft characteristics.

move fireplace inserts, stoves or firebox contents.

perform a smoke test.

dismantle or remove any component.

perform a National Fire Protection Association (NFPA)-style inspection.

perform a Phase I fireplace and chimney inspection.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency

13 - Garage

IN NI NP D
13.1 Ceiling X
13.2 Walls & Firewalls X
13.3 Floor X
13.4 Garage Door X
13.5 Garage Door Opener X
13.6 Occupant Door (From garage to inside of home) X
Garage Door: Type
Automatic
Ceiling: General Photos

Garage ceiling appeared in good overall condition at the time of inspection. It is common for ceilings in the garage to show deterioration at drywall seams, or experience nail pops due to the extreme shifts in temperature throughout the year. Monitor for stains which may indicate a leak in the roof above and repair as needed.

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection.

Walls & Firewalls: Photos

Walls appeared in good overall condition at the time of inspection. 

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection.

Floor: Photos

Garage floor appeared in good overall condition. It is common for concrete floors to experience minor cracking caused by shrinkage or settlement. Monitor cracking for any changes or movement and repair as needed. 

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection.

Garage Door: Material
Metal

Garage door appeared to be in good overall condition. Monitor for any corrosion on metal doors, cracking in fiberglass, or rotting in wood doors and repair as needed.

Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection.

Garage Door Opener: Photos

Garage door openers operated successfully at the time of inspection. Unit(s) successfully reversed when met with pressure and when an object crossed the floor sensors. Any defects or maintenance notes will be listed in the Summary. Photos document condition at the time of inspection. 

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency