Viewing:

1234 Main St.
Dallas, Ga 30132
08/25/2019 9:00AM

Sample agent
agent

Agent Name

Agency Name
5
Maintenance item
10
Recommendation
1
Safety hazard

1 - Inspection Details

In Attendance
Home Owner, Client
Occupancy
Occupied, Furnished
Style
Ranch
Temperature (approximate)
86 Fahrenheit (F)
Type of Building
Single Family
Weather Conditions
Clear
Typical Inspection Sections

2 - Roof

Inspection Method
Binoculars, Ground, Drone
Roof Type/Style
Gable
Flashings: Material
Aluminum, Rubber
Roof Drainage Systems: Gutter Material
Aluminum
Skylights, Chimneys & Other Roof Penetrations: Chimney
Coverings: Material
Asphalt (Laminated)
Credit
Comment
2.2.1 - Roof Drainage Systems

Downspouts Drain Near House

One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor adjust downspout extensions to drain at least 6 feet from the foundation. 

Here is a helpful DIY link and video on draining water flow away from your house. 

Credit
Comment
2.3.1 - Flashings

Vent/Vent Boot (Metal)

Recommend repair or replace rusted vent/vent boots as needed by a qualified, licensed professional. 

Contractor Qualified Professional
Credit
Comment
2.5.1 - Skylights, Chimneys & Other Roof Penetrations

Metal Chimney Rust

The metal chimney shows evidence of rust and/or rusting. Recommend monitoring the chimney which may have to be replaced at some point.

3 - Exterior

Inspection Method
Visual
Siding, Flashing & Trim: Siding Style
Panels, Brick and Mortar
Exterior Windows: Exterior Windows
Walkways, Patios & Driveways: Driveway Material
Concrete
Decks, Balconies, Porches & Steps: Appurtenance
Front Porch, Back Porch
Decks, Balconies, Porches & Steps: Material
Concrete
Chimney: Chimney Location
Siding, Flashing & Trim: Siding Material
Vinyl, Brick Veneer

Observed siding materials in fair condition. 

Recommend minor repairs and as needed as a part of regular home maintenance. 

Exterior Doors: Exterior Entry Door
Storm, Metal clad wood
Siding, Flashing & Trim: Brick

Unable to observe areas between brick veneer and interior wall framing at time of inspection. 

Credit
Comment
3.1.1 - Siding, Flashing & Trim

Trim (Damage/Failure)
Exterior

Trim observed water damaged and with failed paint/sealant which could result in moisture intrusion and damaging leaks. 

Recommend a qualified siding contractor evaluate and repair as needed. 

Credit
Comment
3.4.1 - Exterior Windows

Damage (Rot)
Exterior

Observed significant wood rot at exterior window(s)

Recommend repair or replace as needed by a qualified, licensed professional.  

Contractor Qualified Professional
Credit
Comment
3.5.1 - Walkways, Patios & Driveways

Driveway Cracking (Damage)

Significant cracks/damage observed at driveway. Recommend repair or replace damaged concrete as needed by a qualified, licensed professional. 

Credit
Comment
3.7.1 - Vegetation, Grading, Drainage & Retaining Walls

Vegetation

Recommend cutting vegetation back from structure where in contact throughout exterior. 

Contractor Qualified Professional

4 - Garage

IN NI NP D
4.1 Ceiling X
4.2 Floor X
4.3 Walls & Firewalls X
4.4 Garage Door X
4.5 Garage Door Opener X
4.6 Occupant Door (From garage to inside of home) X
Floor: Flooring Materials
Concrete
Garage Door: Type
Automatic, Sectional, Manual
Ceiling: Ceiling Materials
Sheetrock
Walls & Firewalls: Wall Materials
Sheetrock
Garage Door: Material
Metal, Non-insulated
Garage Door Opener: Garage Door Opener(s)

Garage doors observed functional at time of inspection. 

Occupant Door (From garage to inside of home): Door Material
Metal Clad
Inaccessible Areas

Unable to observe all areas of garage space due to finish materials and/or personal storage. 

Recommend further or additional inspection when areas are accessible.  

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
4.2.1 - Floor

Slab Cracking - Minor

Minor cracking was noted at the garage slab. This is common as concrete ages and shrinkage surface cracks are normal. Recommend monitoring for more serious shifting/displacement. 

Here is an informational article on cracks.

Contractor Qualified Professional
Credit
Comment
4.4.1 - Garage Door

Water Intrusion (Damage)

Observed water intrusion (damage) at garage doors at time of inspection. 

Recommend repair or replace as needed by a qualified, licensed professional.  

Contractor Qualified Professional
Credit
Comment
4.4.2 - Garage Door

Previous Damage/Repair

Observed previous damage/repair to garage door at time of inspection. Observed unit pulling away at time of inspection. 

Recommend repair or replace as needed by a qualified, licensed professional.  

Contractor Qualified Professional

5 - Attic, Insulation & Ventilation

Attic Insulation: Insulation Type
Batt, Fiberglass, Loose-fill
Attic Insulation: R-value
28
Ventilation: Ventilation Type
Ridge Vents, Soffit Vents
Access: Attic Access
Stairs
Attic Framing, Decking: Framing Materials
Truss
Attic Framing, Decking: Decking Materials
OSB/Plywood
Attic Limitations

Not all areas accessible due to finish materials, insulation, and other materials. 

6 - Basement, Foundation, Crawlspace & Structure

IN NI NP D
6.1 Foundation X
Inspection Method
Visual
Foundation: Material
Concrete
General Limitations

Not all areas accessible due to installed finishes, insulation materials, and other materials. 

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
6.1.1 - Foundation

Foundation Cracks - Minor

Minor cracking was noted at the foundation. This is common as concrete/block construction ages and shrinkage surface cracks are normal. 

Recommend repair cracking as needed.

Recommend monitoring for more serious shifting/displacement. 

Here is an informational article on foundation cracks.

7 - HVAC

IN NI NP D
7.1 Normal Operating Controls X
7.2 AC Distribution System X
7.3 Exhaust Systems X
7.4 Piping/Vent Systems X
Normal Operating Controls: Thermostat
Digital
AC Distribution System: AC Configuration
Central
Exhaust Systems: Bathroom Exhaust Fans
Fan Only
Piping/Vent Systems: Ductwork
Insulated
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency

8 - Heating

IN NI NP D
8.1 Equipment X
8.2 Presence of Installed Heat Source in Each Room X
Equipment: Energy Source
Gas
Equipment: Heat Type
Gas-Fired Heat, Forced Air
Equipment: Unit 1
Carrier
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
8.1.1 - Equipment

Unit Nonfunctional

Observed unit non-functional at time of inspection. Unit not producing hot air to registers at time of inspection. Unable to engage heat using thermostat at time of inspection. 

Recommend further consultation with a qualified, licensed hvac contractor to diagnose and suggest repairs as needed for proper function.  

Fire HVAC Professional

9 - Cooling

Cooling Equipment: Energy Source/Type
Electric, Central Air Conditioner
Cooling Equipment: Location
Exterior West
Cooling Equipment: Unit 1
Goodman

10 - Plumbing

IN NI NP D
10.1 Main Water Shut-off Device X
10.2 Drain, Waste, & Vent Systems X
10.3 Water Supply, Distribution Systems & Fixtures X
10.4 Hot Water Systems, Controls, Flues & Vents X
10.5 Fuel Storage & Distribution Systems X
Filters
None
Water Source
Public
Waste System
Sewer
Drain, Waste, & Vent Systems: Drain Size
3”
Drain, Waste, & Vent Systems: Material
PVC
Water Supply, Distribution Systems & Fixtures: Distribution Material
Copper
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Copper
Water Supply, Distribution Systems & Fixtures: Fixtures Operational

Observed fixtures operational throughout structure at time of inspection. 

Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Gas
Hot Water Systems, Controls, Flues & Vents: Age of Unit
2014 Within manufacturer’s anticipated lifespan.
Main Water Shut-off Device: Location
Garage
Hot Water Systems, Controls, Flues & Vents: Capacity
50 gallons
Hot Water Systems, Controls, Flues & Vents: Location
Garage
Fuel Storage & Distribution Systems: Main Gas Shut-off Location
Gas Meter
Hot Water Systems, Controls, Flues & Vents: Manufacturer
Kenmore

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
10.2.1 - Drain, Waste, & Vent Systems

Jet Tub (Nonfunctional)

Hey tub nonfunctional at time of inspection. Unit tripped at time of inspection. Unable to reset. 

Recommend repair or replace as needed by a qualified, licensed professional.  

Contractor Qualified Professional

11 - Electrical

IN NI NP D
11.1 Service Entrance Conductors X
11.2 Main & Subpanels, Service & Grounding, Main Overcurrent Device X
11.3 Branch Wiring Circuits, Breakers & Fuses X
11.4 Lighting Fixtures, Switches & Receptacles X
11.5 GFCI & AFCI X
11.6 Smoke/CO Detectors X
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Manufacturer
Square D
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Type
Circuit Breaker
Branch Wiring Circuits, Breakers & Fuses: Branch Wire 15 and 20 AMP
Copper
Branch Wiring Circuits, Breakers & Fuses: Wiring Method
Romex
GFCI & AFCI: GFCI Outlets

GFCI outlets functional where observed at time of inspection. 

Service Entrance Conductors: Electrical Service Conductors
Below Ground, Aluminum, 120/240V
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main Panel Location
Garage
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Capacity
150 AMP
Lighting Fixtures, Switches & Receptacles: Switches/Outlets

Fixtures/Outlets operating as intended where observed at time of inspection. 

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency

12 - Fireplace

IN NI NP D
12.1 Vents, Flues & Chimneys X
12.2 Lintels X
12.3 Damper Doors X
12.4 Gas Supply/Burner X
Type
Gas
Damper Doors: Damper Door

Damper door observed functional at time of inspection. 

Gas Supply/Burner: Gas Supply
Gas Logs
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
Credit
Comment
12.1.1 - Vents, Flues & Chimneys

Chimney Liner/Flue Dirty

Firebox/liner/flue observed dirty at time of inspection. 

Recommend qualified chimney sweep company inspect and/or clean.

13 - Doors, Windows & Interior

Doors: Door Type
Hinged
Doors: Door Materials
Hollow Core
Windows: Window Manufacturer
Unknown
Windows: Window Type
Double-hung
Windows: Window materials
Wood
Walls: Wall Material
Drywall
Ceilings: Ceiling Material
Wallpaper
Interior Limitations

Due to furniture and personal storage multiple conditions of the interiors were not accessible at time of inspection. 

Recommend further or additional inspection when areas are accessible.  

Credit
Comment
13.1.1 - Doors

Interior Door Locks
Back

Lock nonfunctional at time of inspection. 

Recommend further consultation with a qualified, licensed contractor to diagnose and suggest repairs as needed for proper function.  

Contractor Qualified Professional
Credit
Comment
13.1.2 - Doors

Interior Door(s) (Egress)

Key required locks not recommend for emergency egress door. Doors may be during need for emergency exiting. 

Recommend installation of thumb latch door locks as needed by a qualified, licensed professional.

Contractor Qualified Professional