1234 Main St.
Fairborn, Ohio 45324
04/08/2020 9:00AM

Sample agent
agent

Agent Name

Agency Name
129
Items Inspected
3
Maintenance item
15
Recommendation
7
Safety hazard

1 - Inspection Details

In Attendance
Client, Home Owner
Occupancy
Occupied
Style
Ranch
Temperature (approximate)
63 Fahrenheit (F)
Type of Building
Single Family
Weather Conditions
Clear

2 - General Information/ Notes

IN NI NP D
2.1 Overview X
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

3 - Roof

IN NI NP D
3.1 Coverings X
3.2 Flashings X X
3.3 Roof Drainage Systems X
3.4 Skylights, Chimneys & Other Roof Penetrations X
Inspection Method
Roof
Roof Type/Style
Hip
Roof Drainage Systems: Gutter Guards
Not Present
Roof Drainage Systems: Gutter Drains into Perimeter Tile
Skylights, Chimneys & Other Roof Penetrations: Plumbing Vent Pipe Roof Penetrations
1
Skylights, Chimneys & Other Roof Penetrations: Roof Penetrations
4
Covering Material
Asphalt
Roof Drainage Systems: Gutter Material
Aluminum

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
3.2.1 - Flashings

Corroded - Severe

Roof flashing showed signs of severe corrosion, which can lead to moisture intrusion and/or mold. Recommend a qualified roofing contractor evaluate and repair.

4 - Grounds

IN NI NP D
4.1 Vegitation X X
4.2 Walkways, Patios & Driveways X X
Deck/Patio
Walkways, Patios & Driveways: Front Porch Material
Concrete
Landscaping
Walkways, Patios & Driveways: Driveway Material
Concrete
Walkways, Patios & Driveways: Sidewalk Material
Concrete
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
4.1.1 - Vegitation

Vegetation too close to structure/ incontact with structure

Vegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior and/or other structures. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.

Grass Lawncare Professional
$
Credit
Comment
4.2.1 - Walkways, Patios & Driveways

Driveway Cracking - Minor

Minor cosmetic cracks observed, which may indicate movement in the soil. Recommend monitor and/or have concrete contractor patch/seal.

$
Credit
Comment
4.2.2 - Walkways, Patios & Driveways

Handrail chipping pain

chipping paint on handrail recommend a qualified professional repair finish to prevent further damage.  

Contractor Qualified Professional

5 - Exterior

IN NI NP D
5.1 Siding, Flashing & Trim X
5.2 Exterior Doors X X
5.3 Eaves, Soffits & Fascia X
5.4 Exterior Foundation X X
5.5 Exterior Electrical X
Inspection Method
Visual
Exterior Doors: Back Exterior Entry Door
Glass, Steel
Exterior Doors: Front Exterior Entry Door
Glass, Steel
Exterior Foundation: Material
Concrete
Siding, Flashing & Trim: Siding Material
Brick Veneer
Exterior Foundation: Limitations

Due to the Vegetation overgrowth full evaluation of the exterior foundation could not be obtained.

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
5.2.1 - Exterior Doors

Door Does Not Close or Latch

Door does not close or latch properly. Recommend qualified handyman adjust strike plate and/or lock.

Here is a DIY troubleshooting article on fixing door issues. 

$
Credit
Comment
5.4.1 - Exterior Foundation

Foundation Cracks - Minor

Minor cracking was noted at the foundation. This is common as concrete ages and shrinkage surface cracks are normal. Recommend repairing the skim coat and monitoring for more serious shifting/displacement. 

Here is an informational article on foundation cracks.

6 - Kitchen

IN NI NP D
6.1 General X
6.2 Floors X
6.3 Interior Doors X
6.4 Windows X
6.5 Sinks/Fixtures X
6.6 Walls X
6.7 Ceiling X
6.8 GFCI Protection X
6.9 Switches / Receptacles X
6.10 Lighting & Fans X
6.11 Microwave X
6.12 Range/Oven/Cooktop X
6.13 Exhaust / Ventilation X
6.14 Dishwasher X
6.15 Garbage / Food Disposal X
6.16 Refrigerator X
6.17 Cabinet X X
General: Oven Self Cleaning
Yes
General: Exhaust / Ventilation Type
Built into Mircowave
General: Fridge stays?
Unknown
General: Fridge water supply connection
Yes
Windows: Window Manufacturer
Unknown
Windows: Type
Vinyl
Walls: Wall Material
Drywall
Ceiling: Ceiling Material
Drywall
GFCI Protection: GFCI protection present
Yes, GFCI Reset Present in this Room
General: Range / Oven / Cooktop Energy Source / Supply
Electric (220v)
Floors: Floor Coverings
Engineered Wood

10.1 The inspector shall inspect: F. installed ovens, ranges, surface cooking appliances, microwave ovens, dishwashing machines, and food waste grinders by using normal operating controls to activate the primary function. 10.2 The inspector is NOT required to inspect: G. installed and free-standing kitchen and laundry appliances not listed in Section 10.1.F. H. appliance thermostats including their calibration, adequacy of heating elements, self cleaning oven cycles, indicator lights, door seals, timers, clocks, timed features, and other specialized features of the appliance. I. operate, or con rm the operation of every control and feature of an inspected appliance.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
6.17.1 - Cabinet

Kick board seperated
Kitchen

Kick Board under the kitchen cabinets were not attached properly this can be a trip hazard recommend removing or re securing.  

Contractor Qualified Professional

7 - Living Room

IN NI NP D
7.1 General X
7.2 Floors X
7.3 Interior Doors X
7.4 Windows X
7.5 AFCI Protection X
7.6 Walls X
7.7 Ceiling X
7.8 Switches / Receptacles X X
7.9 Lighting & Fans X
General: Thermostat
Living Room
Floors: Floor Coverings
Engineered Wood
Windows: Window Manufacturer
Unknown
Windows: Type
Sliding, Single-hung
AFCI Protection: AFCI protection present
No
Walls: Wall Material
Drywall
Ceiling: Ceiling Material
Drywall
General: Heat Source Present

Images below dictate the temperature of the air coming from the heat source taken with a thermal camera. Temperature whith the heat on was 88.9 degrees fahrenheit  and 58.1 degrees fahrenheit with the A/C on.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
7.8.1 - Switches / Receptacles

3 Prong Ungrounded 2 Wire

3-slot receptacles (outlets) were installed in one or more areas without a ground wire hookup. These do not have an equipment ground. These outlets should either be swapped out with a 2 prong outlet, or upgrade to grounded receptacles, which typically requires installing new wiring from the main panel. The NEC (National Electric Code) also allows these outlets to be replaced with GFCI protection as a repair to use grounded appliances with them. Appliances that require a ground should not be used with ungrounded receptacles. Examples of such appliances include computers and related hardware, refrigerators, freezers, portable air conditioners, clothes washers, aquarium pumps, and electrically operated gardening tools. The client should be aware of this limitation when planning use for various rooms, such as an office. Consult with a qualified electrician about upgrading to 3-wire, grounded circuits or installing GFCI protection.

Electric Electrical Contractor

8 - Master Bedroom

IN NI NP D
8.1 General X
8.2 Floors X
8.3 Interior Doors X X
8.4 Windows X
8.5 AFCI Protection X
8.6 Walls X
8.7 Ceiling X
8.8 Switches / Receptacles X X
8.9 Lighting & Fans X
General: Heat Source Present
General: Closet
Floors: Floor Coverings
Carpet
Windows: Window Manufacturer
Unknown
Windows: Type
Vinyl
AFCI Protection: AFCI protection present
No
Walls: Wall Material
Drywall
Ceiling: Ceiling Material
Drywall
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
8.3.1 - Interior Doors

Closet Door Off Track

The closet doors in one or more locations were off track. Recommend repair for proper functionality.

Wrenches Handyman
$
Credit
Comment
8.8.1 - Switches / Receptacles

3 Prong Ungrounded 2 Wire

3-slot receptacles (outlets) were installed in one or more areas without a ground wire hookup. These do not have an equipment ground. These outlets should either be swapped out with a 2 prong outlet, or upgrade to grounded receptacles, which typically requires installing new wiring from the main panel. The NEC (National Electric Code) also allows these outlets to be replaced with GFCI protection as a repair to use grounded appliances with them. Appliances that require a ground should not be used with ungrounded receptacles. Examples of such appliances include computers and related hardware, refrigerators, freezers, portable air conditioners, clothes washers, aquarium pumps, and electrically operated gardening tools. The client should be aware of this limitation when planning use for various rooms, such as an office. Consult with a qualified electrician about upgrading to 3-wire, grounded circuits or installing GFCI protection.

Electric Electrical Contractor

9 - Bedroom 2

IN NI NP D
9.1 Floors X
9.2 Interior Doors X
9.3 Windows X
9.4 AFCI Protection X
9.5 Walls X
9.6 Ceiling X
9.7 Switches / Receptacles X X
9.8 Lighting & Fans X
Heat Source Present
Floors: Floor Coverings
Tile
Windows: Window Manufacturer
Unknown
Windows: Window Type
Glass block
Walls: Wall Material
Drywall
Ceiling: Ceiling Material
Drywall
Interior Doors: Could not access the closet

Could not access the closet due to residents belongings being in the way

AFCI Protection not present.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
9.7.1 - Switches / Receptacles

3 Prong Ungrounded 3 Wire

3-slot receptacles (outlets) were installed in one or more areas and tested as not having a ground wire hooked up. As this electric system appears mostly or all grounded, it is likely the wire could be loose, or not connected, or a splice somewhere is loose. Recommend a qualified electrician evaluate and repair.

Electric Electrical Contractor

10 - Master Bathroom

IN NI NP D
10.1 General X
10.2 Lighting Fixtures, Switches & Receptacles X
10.3 GFCI Protection X
10.4 Sinks/Fixtures X
10.5 Toilets/Bidets X
10.6 Bathtub / Shower X
10.7 Countertops & Cabinets X
10.8 Exhaust Fans / Ventilation X
GFCI Protection: GFCI protection present
Yes
Bathtub / Shower: Shower/Tub Material
Fiberglass
Bathtub / Shower: Exhaust Fan
Fan/Light
Bathtub / Shower: Shower/Tub Style
Shower/Tub
Countertops & Cabinets: Cabinetry
Laminate
Countertops & Cabinets: Countertop Material
Marble
Exhaust Fans / Ventilation: Type
Exhaust fan
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

11 - Bathroom 2

IN NI NP D
11.1 General X X
11.2 Lighting Fixtures, Switches & Receptacles X
11.3 GFCI Protection X
11.4 Sinks/Fixtures X
11.5 Toilets/Bidets X
11.6 Bathtub / Shower X
11.7 Countertops & Cabinets X
11.8 Exhaust Fans / Ventilation X
GFCI Protection: GFCI protection present
Yes
Exhaust Fans / Ventilation: Type
Window
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
11.1.1 - General

Door handle missing

Door handle is broken/missing recommend replacing door handle.

Contractor Qualified Professional

12 - Laundry Room

IN NI NP D
12.1 General X
12.2 Appliance Connections X
12.3 Floors X
12.4 Drain, Waste, & Vent Systems X
12.5 Interior Doors X
12.6 Windows X
12.7 GFCI Protection X
12.8 Sinks/Fixtures X
12.9 Walls X X
12.10 Ceiling X
12.11 Switches / Receptacles X
12.12 Lighting & Fans X
General: Present
Washer, Dryer
Floors: Floor Coverings
Tile
Drain, Waste, & Vent Systems: Drain Size
1 1/2"
Drain, Waste, & Vent Systems: Material
Unknown
Windows: Window Manufacturer
Unknown, Glass block
GFCI Protection: GFCI protection present
Yes, GFCI Reset Present in this Room
Walls: Wall Material
Drywall
Appliance Connections: Information
240 Volt Electric, 110 Volt Electric
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
12.9.1 - Walls

Water damage

Contractor Qualified Professional

13 - HVAC

IN NI NP D
13.1 General comments X
13.2 Heating / Forced Air X
13.3 Air Conditioner X X
13.4 Ducts and Registers X
13.5 Filter & Thermostat X
Heating / Forced Air: Location
Basement
Heating / Forced Air: Energy source
Natural gas
Air Conditioner: Location
Exterior
Air Conditioner: System Type
Split system
Filter & Thermostat: Filter Location(s)
Basement
Filter & Thermostat: T-stat Location(s)
Living Room
Heating / Forced Air: Estimated Year Mfg.
Basement
2014

2014

Ducts and Registers: Type
Ducts and Registers
Heating / Forced Air: Appears Functional

Heat system appears to be in working order. The photo(s) below is/are a thermal image of the supply air temperature at register(s) at the time of this inspection.

Heating / Forced Air: Equipment Photos
Air Conditioner: Estimated Year Mfg.
Unknown
Air Conditioner: Appears Functional

The temperature split differential between the return air and supply registers was within the 14-22 degree (F) range at time of inspection.

The photo(s) below is/are a thermal image of the air temperature at supply and return air register(s) at the time of this inspection.

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
13.1.1 - General comments

Service Heating / Cooling System

The last service date of the forced air heating / cooling system appeared to be more than 1 year ago, or the inspector was unable to determine the last service date. Ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than 1 year ago, recommend that a qualified HVAC contractor service this system and make repairs if necessary. Because this system has a compressor and refrigerant system, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the contractor when it's serviced.

Fire HVAC Professional
$
Credit
Comment
13.3.1 - Air Conditioner

Near Lifespan

By industry lifespan standards, one or more hvac components appeared to be at or near its useful lifespan (~15 years)and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the near future or discussing replacement options with a qualified HVAC technician to determine applicable costs.

Fire HVAC Professional

14 - Plumbing

IN NI NP D
14.1 Excluded Items X
14.2 Service X
14.3 Supply Lines X
14.4 Drain, Waste, & Vent Systems X
14.5 Water Heater X
14.6 Fuel Systems X
Service: Water Service Type
Public
Service: Water meter location
By street
Service: Water service Material
Unknown / Not Visible
Service: Water Shut-Off Location
Basement
Service: Pressure Regulator Present
Unknown
Service: Sewer Type
Public
Supply Lines: Materials
PEX
Drain, Waste, & Vent Systems: Drain Line Materials
PVC
Drain, Waste, & Vent Systems: Waste Line Materials
Unknown / Not Visible
Drain, Waste, & Vent Systems: Vent Materials
PVC
Drain, Waste, & Vent Systems: Clean-out Location(s)
Basement
Water Heater: Estimated Mfg. Year
2014
Water Heater: Energy Source / Type
Gas
Water Heater: Capacity
40 Gallon
Water Heater: Location
Basement
Fuel Systems: Fuel Service Type
Natural Gas
Fuel Systems: Main Gas Shut-off Location
Gas Meter

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

15 - Basement, Foundation, Crawlspace

IN NI NP D
15.1 Foundation X
15.2 Basements & Crawlspaces X
15.3 Floor Structure X X
15.4 GFCI Protection X
15.5 Wall Structure X
15.6 Ceiling Structure X
Inspection Method
Infrared, Visual
Floor Structure: Basement/Crawlspace Floor
Concrete
Floor Structure: Material
Wood Beams
Floor Structure: Sub-floor
Plank
GFCI Protection: GFCI protection present
Yes
Foundation: Material
Concrete

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
15.3.1 - Floor Structure

Termite damage

Evidence of termites were found recommend repair foundation crack, termite treatment and monitor. Due to wall coverings and floor coverings on the first floor full evaluation of the damage could not be accessed.

Contractor Qualified Professional

16 - Electrical

IN NI NP D
16.1 Excluded Items X
16.2 Service X
16.3 Panels X
16.4 GFCI / AFCI Protection- Extended X
16.5 Panel Wiring & Breakers X
16.6 Wiring X X
16.7 Smoke Detectors / CO Alarms / Door Bell X X
Wiring: Wiring Type
Copper
Service: Information
120-240 Voltage
Service: Entrance Conductor Material
Aluminum
Panels: Main Panel Location
Basement
Panels: Panel Capacity
100 AMP
Panels: Main disconnect rating
100 Amp
Panel Wiring & Breakers: Over protection devices
Breakers
GFCI / AFCI Protection- Extended: GFCI protection present- Extended
Yes

A Ground Fault Circuit Interrupter (GFCI) - Is an ultra sensitive receptacle outlet and/or breaker designed to shut off all electric current. Used in bathrooms, kitchens, exterior waterproof outlets, garage outlets, and "wet areas" to prevent electrical shock. Has a small reset / test button on the receptacle and/or breaker.

GFCI / AFCI Protection- Extended: AFCI protection present- Extended
Yes

An Arc Fault Circuit Interrupter (AFCI) is a circuit breaker that breaks the circuit when it detects an electric arc in the circuit it protects to prevent electrical fires. An AFCI selectively distinguishes between a harmless arc (incidental to normal operation of switches, plugs, and brushed motors), and a potentially dangerous arc (that can occur, for example, in a lamp cord which has a broken conductor).

Smoke Detectors / CO Alarms / Door Bell: Smoke Detector Installed / Location(s)
No, Hallway

Note: Smoke detectors are tested only for audibility and not tested using actual smoke.

Smoke Detectors / CO Alarms / Door Bell: Carbon Monoxide Alarm(s) Installed / Location(s)
No

Note: Carbon Monoxide alarms are tested only for audibility and not tested using actual Carbon Monoxide.

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any time controlled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
16.1.1 - Excluded Items

Cable / Satellite / Telephone / Inter Communication / Alarm Stystems

Note: If present, cable, satellite, telephone, inter communication and alarm systems are not inspected. Evaluating these systems are beyond the scope of a property inspection. Their condition is unknown, and they are excluded from this inspection. Recommend that a qualified specialist review these systems and make repairs if necessary.

Contractor Qualified Professional
$
Credit
Comment
16.6.1 - Wiring

Phone cable detached from house

Phone cable was detached from the house recommend a qualified professional attaching cable to the house.

Contractor Qualified Professional
$
Credit
Comment
16.7.1 - Smoke Detectors / CO Alarms / Door Bell

Smoke Detector Missing

Smoke alarms were missing and/or not installed in one or more locations. Smoke alarms should be replaced as necessary and installed per standard building practices (e.g. in hallways leading to bedrooms, in each bedroom, on each floor). We recommend installing photoelectric type smoke detectors / alarms.

Note: Homes built prior to 1992 were not required to have smoke detectors installed in each bedroom, only hallways. Regardless, calfire.ca.gov recommends installing smoke detectors in each bedroom for increased safety. Click here for more information.

Tools Handyman/DIY

17 - Garage

IN NI NP D
17.1 Floors X
17.2 Walls X
17.3 Ceiling X
17.4 Windows X
17.5 Switches / Receptacles X X
17.6 GFCI Protection X
17.7 Man Doors X X
17.8 Garage Door X X
17.9 Lighting & Fans X X
17.10 Garage Door Opener X
17.11 Electric X X
17.12 Exterior X X
Detached
Floors: Floor Coverings
Concrete
Windows: Window Manufacturer
Unknown
Windows: Window Type
Single Pane
GFCI Protection: GFCI protection present
No
Garage Door: Material
Metal, Insulated
Garage Door: Type
Sliding
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
$
Credit
Comment
17.5.1 - Switches / Receptacles

Receptacle / Switch Loose

One or more electric receptacles, switches and/or the boxes in which they were installed were loose and/or not securely anchored. Wire conductors can be damaged due to repeated movement and/or tension on wires, or insulation can be damaged. This is a shock and fire hazard. Recommend that a qualified electrician repair as necessary.

Electric Electrical Contractor
$
Credit
Comment
17.7.1 - Man Doors

Binds in / Drags Jamb

One or more interior doors were binding and/or dragging the jamb. Recommend that a qualified person repair as necessary. For example, by trimming doors.

Door Door Repair and Installation Contractor
$
Credit
Comment
17.7.2 - Man Doors

Chipped paint

Recommend a qualified professional repair chipped paint.

Paint roller Painting Contractor
$
Credit
Comment
17.9.1 - Lighting & Fans

Bulbs Missing/Broken

Bulbs in one or more light fixtures were missing or broken. These light fixtures couldn't be fully evaluated. If replacement bulbs are inoperable, then recommend that a qualified electrician evaluate and repair or replace light fixtures as necessary.

Electric Electrical Contractor
$
Credit
Comment
17.11.1 - Electric

Broken conduit

Entrance conduit to the garage is broken and wires exposed recommend a qualified electrician repair as necessary. 

Electric Electrical Contractor
$
Credit
Comment
17.12.1 - Exterior

Facia

Fascia on the garage is missing recommend a qualified professional repair to prevent further damage to the exposed wood.

Contractor Qualified Professional