Viewing:

1234 Main St.
Fairborn, Ohio 45324
04/08/2020 9:00AM

Sample agent
agent

Agent Name

Agency Name
120
Items Inspected
4
Maintenance item
25
Recommendation
5
Safety hazard

1 - General

2 - Inspection Details

General: In Attendance
Client, Home Owner, Client's Agent
General: Occupancy
Occupied
General: Style
Multi-level
General: Temperature (approximate)
80 Fahrenheit (F)
General: Type of Building
Multi-Family
General: Weather Conditions
Clear

3 - General Information/ Notes

IN NI NP O
3.1 General X
3.2 Overview X
3.3 About Thermal Imaging X
3.4 Comment Key and Definition X
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations

4 - Grounds

IN NI NP O
4.1 General X
4.2 Vegitation X X
4.3 Walkways, Patios & Driveways X X
Walkways, Patios & Driveways: Sidewalk Material
Concrete
Walkways, Patios & Driveways: Front Porch Material
Concrete
Walkways, Patios & Driveways: Driveway Material
Asphalt
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
4.2.1 - Vegitation

Overgrowth

The property has overgrown vegetation that needs to be landscaped. Overgrown landscaping can cause damage to the exterior finish of the house. Vegetation should be cut and kept clear of the exterior of the home.  

Yard scissors Landscaping Contractor
$
Credit
Comment
4.2.2 - Vegitation

Tree Near Foundation

One or more large trees were very close to the foundation. Tree roots can cause significant structural damage to foundations, or may have already caused damage (see other comments in this report). Recommend that a qualified tree service contractor or certified arborist remove trees as necessary to prevent damage to foundations.

Yard scissors Tree Service
$
Credit
Comment
4.3.1 - Walkways, Patios & Driveways

Driveway Cracking - Minor

Minor cracks observed, This happens as Asphalt ages. Recommend monitor and/or have contractor patch/seal driveway.

5 - Roof

IN NI NP O
5.1 General X
5.2 Coverings X X
5.3 Flashings X X
5.4 Roof Drainage Systems X X
5.5 Skylights, Chimneys & Other Roof Penetrations X X
General: Inspection Method
Ladder
General: Roof Type/Style
Hip
Roof Drainage Systems: Gutter Materiallp pop in a look
Aluminum
Roof Drainage Systems: Gutter Guards
Not Present
Skylights, Chimneys & Other Roof Penetrations: Chimney Roof Penetrations
1
Skylights, Chimneys & Other Roof Penetrations: Plumbing Vent Pipe Roof Penetrations
Not Present
General: Covering Material
Asphalt

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
5.2.1 - Coverings

Delamination

The asphalt shingle roof shows signs of delamination. Delamination is separation of the surface layer of asphalt. Recommend a qualified roofing contractor evaluate and repair to prevent further deterioration that results in leaking and moisture intrusion. 

$
Credit
Comment
5.2.2 - Coverings

Roof Shingle(s) Cracked and/or Brittle

One or more roof shingles were cracked and/or brittle. This happens towards the end of the shingles life. Recommend a qualified Roofing Professional Repair as necessary.

Roof Roofing Professional
$
Credit
Comment
5.4.1 - Roof Drainage Systems

Debris

Debris has accumulated in the gutters. Recommend cleaning to facilitate water flow.

Here is a DIY resource for cleaning your gutters. 

$
Credit
Comment
5.4.2 - Roof Drainage Systems

Downspouts Drain Near House

One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor adjust downspout extensions to drain at least 6 feet from the foundation. 

Here is a helpful DIY link and video on draining water flow away from your house. 

$
Credit
Comment
5.4.3 - Roof Drainage Systems

Downspouts Missing

Home was missing downspouts in one or more areas. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor install downspout extensions that drain at least 6 feet from the foundation. Here is a DIY on Folding Downspout Extensions for when the extension extends into the lawn.

Gutter cleaning icon Gutter Contractor
$
Credit
Comment
5.4.4 - Roof Drainage Systems

Gutter Damaged

Gutters were damaged. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor evaluate and repair. 

$
Credit
Comment
5.5.1 - Skylights, Chimneys & Other Roof Penetrations

Chimney cap minor cracking

Chimney Cap Minor Cracking this happens as mortar ages. Recommend patching chimney cap and continue to monitor. 

Brick Masonry Restoration Contractor

6 - Exterior

IN NI NP O
6.1 General X
6.2 Siding, Flashing & Trim X X
6.3 Exterior Doors X
6.4 Eaves, Soffits & Fascia X X
6.5 Exterior Foundation X X
6.6 Exterior Electrical X
General: Inspection Method
Visual
Exterior Doors: Back Exterior Entry Door
Steel
Exterior Foundation: Material
Concrete
Exterior Doors: Front Exterior Entry Door
Steel
Exterior Doors: Garage Exterior Entry Door
Wood
Siding, Flashing & Trim: Siding Material
Brick

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
6.2.1 - Siding, Flashing & Trim

Nail pop

Nails on the flashing over the entry door are popping or are under driven. Recommend driving nails in and sealing the nail head with an approved exterior sealant.

Contractor Qualified Professional
$
Credit
Comment
6.2.2 - Siding, Flashing & Trim

Window Trim

Caulk on the window trim has failed. Recommend removing Caulk and sealing with an approved exterior sealant.

Contractor Qualified Professional
$
Credit
Comment
6.4.1 - Eaves, Soffits & Fascia

Paint/Finish Failing

The paint or finish is failing. This can lead to deterioration and rot of the material. Recommend that the araes be properly prepared and painted / finished.

$
Credit
Comment
6.5.1 - Exterior Foundation

Foundation Cracks - Minor

Minor cracking was noted at the foundation. This is common as concrete ages and shrinkage surface cracks are normal. Recommend monitoring for more serious shifting/displacement. 

Here is an informational article on foundation cracks.

7 - Common Area (s)

IN NI NP O
7.1 General X
7.2 Floors X
7.3 Interior Doors X
7.4 Windows X
7.5 Walls X
7.6 Ceiling X
7.7 Switches / Receptacles X
7.8 Lighting & Fans X X
General: Heat Source Present
Floors: Floor Coverings
Vinyl
Walls: Wall Material
Plaster
Ceiling: Ceiling Material
Plaster

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steam generating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
7.8.1 - Lighting & Fans

Light not working
Common Area Front and Back

Lights in common Area are on timmers. The lights should be controlled by a Photocell or a motion sensor so the lights will activated when needed

Contractor Qualified Professional

8 - Basement, Foundation, Crawlspace

IN NI NP O
8.1 General X
8.2 Foundation X X
8.3 Basements & Crawlspaces X X
8.4 Floor Structure X
8.5 GFCI Protection X X
8.6 Wall Structure X
8.7 Ceiling Structure X
Foundation: Material
Concrete
Floor Structure: Basement/Crawlspace Floor
Concrete
Floor Structure: Material
Concrete
Floor Structure: Sub-floor
OSB
GFCI Protection: GFCI protection present
No
General: Inspection Method
Infrared, Visual

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
8.2.1 - Foundation

Foundation Cracks - Minor

Minor cracking was noted at the foundation. This is common as concrete ages and shrinkage surface cracks are normal. Recommend monitoring for more serious shifting/displacement. 

Here is an informational article on foundation cracks.

$
Credit
Comment
8.3.1 - Basements & Crawlspaces

High Moisture Levels

High levels of moisture were noted in areas of the basement. Recommend monitoring and finding source of moisture intrusion. Keep a dehumidifier in the basement.

$
Credit
Comment
8.5.1 - GFCI Protection

Missing GFCI Protection

One or more locations at this property were noted as not having GFCI protection or the inspector was unable to verify if GFCI protection existed at these locations. Adoption of GFCI outlets was generally phased in over numerous years/decades. Recommend client evaluate upgrading these areas to GFCI protection at their discretion.

General guidelines for GFCI-protected receptacles include the following locations:

  1. Outdoors (since 1973)
  2. Bathrooms (since 1975)
  3. Garages(since 1978)
  4. Kitchens (since 1987)
  5. Crawl spaces and unfinished basements (since 1990)
  6. Wet bar sinks (since 1993)
  7. Laundry and utility sinks (since 2005)


Electric Electrical Contractor

9 - Attic, Insulation & Ventilation

IN NI NP O
9.1 General X
9.2 Attic Insulation X
9.3 Ventilation X
General: Dryer Power Source
220 Electric
General: Dryer Vent
Metal (Flex)
General: Flooring Insulation
None
Attic Insulation: Insulation Type
Batt, Fiberglass, Blown
Ventilation: Ventilation Type
Gable Vents
Attic Insulation: R-value
20

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations

10 - Unit 1

IN NI NP O
10.1 Excluded Items X
10.2 Kitchen Details X
10.3 Bathroom Details X
10.4 Bedroom 1 Details X
10.5 Hot Water Systems, Controls, Flues & Vents X
10.6 Ducts and Registers X
10.7 Living Room Details X
10.8 Interior Electrical X
10.9 Smoke Detectors / CO Alarms / Door Bell X
10.10 Air Conditioner X
10.11 Heating / Forced Air X X
Rooms a Heat Source is Present
Kitchen, Bathroom 1, Living Room, Bedroom 1
Thermostat Locations
Living Room
Kitchen Details: Kitchen Cabinets
MDF
Kitchen Details: Counter Tops
Laminate
Kitchen Details: Range / Oven / Cooktop Energy Source / Supply
Electric (220v)
Kitchen Details: Exhaust / Ventilation Type
None
Bathroom Details: Exhaust Fan
Window
Bathroom Details: Shower/Tub style and material
Tub/Shower, Fiberglass, Cast Iorn
Bathroom Details: Vanity Material
MDF, Marble
Bedroom 1 Details: Ceiling Material
Plaster
Bedroom 1 Details: Floor Coverings
Engineered Wood
Bedroom 1 Details: Wall Material
Drywall
Bedroom 1 Details: Window Type/Material
Vinyl, Double-hung
Hot Water Systems, Controls, Flues & Vents: Location
Basement
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Gas
Ducts and Registers: Type
Ducts and Registers
Living Room Details: Ceiling Material
Plaster
Living Room Details: Floor Coverings
Engineered Wood
Living Room Details: Wall Material
Drywall
Living Room Details: Window Type/Material
Vinyl, Double-hung
Interior Electrical: GFCI protection present
Kitchen, Bathroom
Interior Electrical: AFCI protection present
Not Present
Heating / Forced Air: Estimated Year Mfg.
2015
Heating / Forced Air: Energy source
Natural gas
Hot Water Systems, Controls, Flues & Vents: Capacity
40 gallons
Bathroom Details: Bathroom Sinks

At the time of the inspection all bathroom sinks were fully operational and no leaks were found.

Bathroom Details: Tub/Shower

At the time of the inspection all shower fixtures and drains worked as they should. The tub/shower and shroud were in good condition. No defects were observed 

Bathroom Details: Toilet

At the time of the inspection all toilets were fully operational and no leaks were observed.

Hot Water Systems, Controls, Flues & Vents: Manufacturer
Whirlpool

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

Smoke Detectors / CO Alarms / Door Bell: Smoke Detector Installed / Location(s)
Yes, Kitchen

Note: Smoke detectors are tested only for audibility and not tested using actual smoke.

Smoke Detectors / CO Alarms / Door Bell: Carbon Monoxide Alarm(s) Installed / Location(s)
No

Note: Carbon Monoxide alarms are tested only for audibility and not tested using actual Carbon Monoxide.

Air Conditioner: Appears Functional

The temperature split differential between the return air and supply registers was within the 14-22 degree (F) range at time of inspection.

The photo(s) below is/are a thermal image of the air temperature at supply and return air register(s) at the time of this inspection.

Heating / Forced Air: Location
Basement
Heating / Forced Air: Appears Functional

Heat system appears to be in working order. Supply air from the heating system should be 100 degrees Fahrenheit or higher. 

The photo(s) below is/are a thermal image of the supply air temperature at register(s) at the time of this inspection.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
10.1.1 - Excluded Items

Cable / Satellite / Telephone / Inter Communication / Alarm Stystems

Note: If present, cable, satellite, telephone, inter communication and alarm systems are not inspected. Evaluating these systems are beyond the scope of a property inspection. Their condition is unknown, and they are excluded from this inspection. Recommend that a qualified specialist review these systems and make repairs if necessary.

Contractor Qualified Professional
$
Credit
Comment
10.11.1 - Heating / Forced Air

Not fully evaluated

Door was instructed by gas line recommend moving gas line away from access door

Contractor Qualified Professional

11 - Unit 2

IN NI NP O
11.1 Excluded Items X
11.2 General X
11.3 Kitchen Details X
11.4 Living Room Details X
11.5 Bathroom Details X X
11.6 Bedroom 1 Details X
11.7 Hot Water Systems, Controls, Flues & Vents X
11.8 Ducts and Registers X
11.9 Interior Electrical X
11.10 Smoke Detectors / CO Alarms / Door Bell X
11.11 Air Conditioner X
11.12 Heating / Forced Air X
11.13 Filter & Thermostat X
General: Rooms a Heat Source is Present
Kitchen, Bathroom 1, Living Room, Bedroom 1
General: Thermostat Locations
Living Room
Kitchen Details: Counter Tops
Laminate
Kitchen Details: Range / Oven / Cooktop Energy Source / Supply
Electric (220v)
Kitchen Details: Exhaust / Ventilation Type
None
Living Room Details: Ceiling Material
Plaster
Living Room Details: Floor Coverings
Engineered Wood
Living Room Details: Wall Material
Drywall
Living Room Details: Type
Vinyl, Double-hung
Bathroom Details: Exhaust Fan
Window
Bathroom Details: Shower/Tub style and material
Tile, Cast Iorn
Bathroom Details: Vanity Material
Pedistal
Bedroom 1 Details: Ceiling Material
Plaster
Bedroom 1 Details: Floor Coverings
Hardwood
Bedroom 1 Details: Wall Material
Drywall
Bedroom 1 Details: Window Type/Material
Vinyl, Double-hung
Hot Water Systems, Controls, Flues & Vents: Location
Basement
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Gas
Ducts and Registers: Type
Ducts and Registers
Interior Electrical: GFCI protection present
Kitchen, Bathroom
Interior Electrical: AFCI protection present
Living Room, Bedroom 1
Heating / Forced Air: Estimated Year Mfg.
2015
Heating / Forced Air: Location
Basement
Heating / Forced Air: Energy source
Natural gas
Hot Water Systems, Controls, Flues & Vents: Capacity
40 gallons
Kitchen Details: Kitchen Cabinets
MDF
Bathroom Details: Bathroom Sinks

At the time of the inspection all bathroom sinks were fully operational and no leaks were found.

Bathroom Details: Tub/Shower

At the time of the inspection all shower fixtures and drains worked as they should. The tub/shower and shroud were in good condition. No defects were observed 

Hot Water Systems, Controls, Flues & Vents: Manufacturer
Whirlpool

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

Smoke Detectors / CO Alarms / Door Bell: Smoke Detector Installed / Location(s)
Yes, Bedrooms, Kitchen

Note: Smoke detectors are tested only for audibility and not tested using actual smoke.

Smoke Detectors / CO Alarms / Door Bell: Carbon Monoxide Alarm(s) Installed / Location(s)
Yes

Note: Carbon Monoxide alarms are tested only for audibility and not tested using actual Carbon Monoxide.

Air Conditioner: Appears Functional

The temperature split differential between the return air and supply registers was within the 14-22 degree (F) range at time of inspection.

The photo(s) below is/are a thermal image of the air temperature at supply and return air register(s) at the time of this inspection.

Heating / Forced Air: Appears Functional

Heat system appears to be in working order. Supply air from the heating system should be 100 degrees Fahrenheit or higher. 

The photo(s) below is/are a thermal image of the supply air temperature at register(s) at the time of this inspection.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
11.1.1 - Excluded Items

Cable / Satellite / Telephone / Inter Communication / Alarm Stystems

Note: If present, cable, satellite, telephone, inter communication and alarm systems are not inspected. Evaluating these systems are beyond the scope of a property inspection. Their condition is unknown, and they are excluded from this inspection. Recommend that a qualified specialist review these systems and make repairs if necessary.

Contractor Qualified Professional
$
Credit
Comment
11.5.1 - Bathroom Details

Toilet Loose

Toilet was noted as being loose where it attached to the floor. Leaks can occur. As the inspector cannot determine the condition of the wax ring underneath which seals the toilet, it is recommended that a qualified contractor remove the toilet(s) for further evaluation and repair if deemed necessary. A new wax ring should be installed and toilet(s) should be securely anchored to the floor to prevent movement and leaking.
Pipes Plumbing Contractor

12 - Unit 3

IN NI NP O
12.1 Excluded Items X
12.2 General X
12.3 Kitchen Details X
12.4 Bathroom Details X X
12.5 Bedroom 1 Details X
12.6 Hot Water Systems, Controls, Flues & Vents X
12.7 Ducts and Registers X
12.8 Living Room Details X
12.9 Interior Electrical X X
12.10 Smoke Detectors / CO Alarms / Door Bell X
12.11 Air Conditioner X
12.12 Heating / Forced Air X
General: Rooms a Heat Source is Present
Kitchen, Living Room, Bathroom 1, Bedroom 1
General: Thermostat Locations
Living Room
Kitchen Details: Counter Tops
Laminate
Kitchen Details: Range / Oven / Cooktop Energy Source / Supply
Electric (220v)
Kitchen Details: Exhaust / Ventilation Type
None
Bathroom Details: Exhaust Fan
Window
Bathroom Details: Shower/Tub style and material
Tub/Shower, Cast Iorn, Fiberglass
Bathroom Details: Vanity Material
MDF, Marble
Bedroom 1 Details: Ceiling Material
Plaster
Bedroom 1 Details: Floor Coverings
Hardwood
Bedroom 1 Details: Wall Material
Plaster
Bedroom 1 Details: Window Type/Material
Vinyl, Double-hung
Hot Water Systems, Controls, Flues & Vents: Location
Basement
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Gas
Ducts and Registers: Type
Ducts and Registers
Living Room Details: Ceiling Material
Plaster
Living Room Details: Floor Coverings
Hardwood
Living Room Details: Wall Material
Drywall
Living Room Details: Window Type/ material
Vinyl, Double-hung
Interior Electrical: GFCI protection present
Kitchen
Interior Electrical: AFCI protection present
Living Room, Bedroom 1
Heating / Forced Air: Estimated Year Mfg.
2015
Heating / Forced Air: Location
Basement
Heating / Forced Air: Energy source
Natural gas
Kitchen Details: Kitchen Cabinets
Plywood
Bathroom Details: Bathroom Sinks

At the time of the inspection all bathroom sinks were fully operational and no leaks were found.

Bathroom Details: Tub/Shower

At the time of the inspection all shower fixtures and drains worked as they should. The tub/shower and shroud were in good condition. No defects were observed 

Bathroom Details: Toilet

At the time of the inspection all toilets were fully operational and no leaks were observed.

Hot Water Systems, Controls, Flues & Vents: Capacity
40 gallons
Hot Water Systems, Controls, Flues & Vents: Manufacturer
Whirlpool

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

Smoke Detectors / CO Alarms / Door Bell: Smoke Detector Installed / Location(s)
Yes, Kitchen

Note: Smoke detectors are tested only for audibility and not tested using actual smoke.

Smoke Detectors / CO Alarms / Door Bell: Carbon Monoxide Alarm(s) Installed / Location(s)
No

Note: Carbon Monoxide alarms are tested only for audibility and not tested using actual Carbon Monoxide.

Air Conditioner: Appears Functional

The temperature split differential between the return air and supply registers was within the 14-22 degree (F) range at time of inspection.

The photo(s) below is/are a thermal image of the air temperature at supply and return air register(s) at the time of this inspection.

Heating / Forced Air: Appears Functional

Heat system appears to be in working order. Supply air from the heating system should be 100 degrees Fahrenheit or higher. 

The photo(s) below is/are a thermal image of the supply air temperature at register(s) at the time of this inspection.

Heating / Forced Air: Equipment Photos
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
12.1.1 - Excluded Items

Cable / Satellite / Telephone / Inter Communication / Alarm Stystems

Note: If present, cable, satellite, telephone, inter communication and alarm systems are not inspected. Evaluating these systems are beyond the scope of a property inspection. Their condition is unknown, and they are excluded from this inspection. Recommend that a qualified specialist review these systems and make repairs if necessary.

Contractor Qualified Professional
$
Credit
Comment
12.4.1 - Bathroom Details

Stopper Inoperable / Missing / Difficult / Ineffective

One or more sink and/or tub stoppers were inoperable, missing, difficult to operate and/or ineffective.

Pipes Plumbing Contractor
$
Credit
Comment
12.9.1 - Interior Electrical

GFCI Issues

One or more ground fault circuit interrupter (GFCI) receptacles (outlets) were not functioning properly (would not trip / would not reset / still energized when tripped). Recommend repairs be made by a qualified licensed electrical contractor. For example, replacing with new GFCI receptacle outlet.

Electric Electrical Contractor
$
Credit
Comment
12.9.2 - Interior Electrical

Receptacle / Switch Loose

One or more electric receptacles, switches and/or the boxes in which they were installed were loose and/or not securely anchored. Wire conductors can be damaged due to repeated movement and/or tension on wires, or insulation can be damaged. This is a shock and fire hazard. Recommend that a qualified electrician repair as necessary.

Electric Electrical Contractor

13 - Unit 4

IN NI NP O
13.1 Excluded Items X
13.2 General X
13.3 Kitchen Details X
13.4 Living Room Details X X
13.5 Bathroom Details X X
13.6 Bedroom 1 Details X
13.7 Interior Electrical X X
13.8 Hot Water Systems, Controls, Flues & Vents X
13.9 Ducts and Registers X
13.10 Smoke Detectors / CO Alarms / Door Bell X
13.11 Air Conditioner X
13.12 Heating / Forced Air X
13.13 Filter & Thermostat X
General: Rooms a Heat Source is Present
Living Room, Kitchen, Bathroom 1, Bedroom 1
General: Thermostat Locations
Living Room
Kitchen Details: Kitchen Cabinets
Plywood
Kitchen Details: Counter Tops
Laminate
Kitchen Details: Range / Oven / Cooktop Energy Source / Supply
Electric (220v)
Kitchen Details: Exhaust / Ventilation Type
None
Living Room Details: Ceiling Material
Plaster
Living Room Details: Floor Coverings
Hardwood
Living Room Details: Wall Material
Drywall
Living Room Details: Type
Vinyl, Double-hung
Bathroom Details: Exhaust Fan
Window
Bathroom Details: Shower/Tub style and material
Tub/Shower, Cast Iorn, Fiberglass
Bathroom Details: Vanity Material
MDF, Marble
Bedroom 1 Details: Ceiling Material
Plaster
Bedroom 1 Details: Floor Coverings
Carpet
Bedroom 1 Details: Wall Material
Drywall
Bedroom 1 Details: Window Type/Material
Vinyl, Double-hung
Interior Electrical: GFCI protection present
Kitchen, Bathroom
Interior Electrical: AFCI protection present
Living Room, Bedroom 1
Hot Water Systems, Controls, Flues & Vents: Location
Basement
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Gas
Ducts and Registers: Type
Ducts and Registers
Heating / Forced Air: Estimated Year Mfg.
2015
Heating / Forced Air: Location
Basement
Heating / Forced Air: Energy source
Natural gas
Filter & Thermostat: Filter Location(s)
Basement
Filter & Thermostat: Filter Size
16x25x1
Filter & Thermostat: T-stat Location(s)
Living Room
Hot Water Systems, Controls, Flues & Vents: Capacity
40 gallons
Bathroom Details: Bathroom Sinks

At the time of the inspection all bathroom sinks were fully operational and no leaks were found.

Bathroom Details: Tub/Shower

At the time of the inspection all shower fixtures and drains worked as they should. The tub/shower and shroud were in good condition. No defects were observed 

Bathroom Details: Toilet

At the time of the inspection all toilets were fully operational and no leaks were observed.

Hot Water Systems, Controls, Flues & Vents: Manufacturer
Whirlpool

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

Smoke Detectors / CO Alarms / Door Bell: Smoke Detector Installed / Location(s)
Yes, Kitchen

Note: Smoke detectors are tested only for audibility and not tested using actual smoke.

Smoke Detectors / CO Alarms / Door Bell: Carbon Monoxide Alarm(s) Installed / Location(s)
No

Note: Carbon Monoxide alarms are tested only for audibility and not tested using actual Carbon Monoxide.

Air Conditioner: Appears Functional

The temperature split differential between the return air and supply registers was within the 14-22 degree (F) range at time of inspection.

The photo(s) below is/are a thermal image of the air temperature at supply and return air register(s) at the time of this inspection.

Heating / Forced Air: Appears Functional

Heat system appears to be in working order. Supply air from the heating system should be 100 degrees Fahrenheit or higher. 

The photo(s) below is/are a thermal image of the supply air temperature at register(s) at the time of this inspection.

Heating / Forced Air: Furnace Abandoned / Not In Service

Note: A furnace has been abandoned and no longer in service and has not been removed.Note

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
13.1.1 - Excluded Items

Cable / Satellite / Telephone / Inter Communication / Alarm Stystems

Note: If present, cable, satellite, telephone, inter communication and alarm systems are not inspected. Evaluating these systems are beyond the scope of a property inspection. Their condition is unknown, and they are excluded from this inspection. Recommend that a qualified specialist review these systems and make repairs if necessary.

Contractor Qualified Professional
$
Credit
Comment
13.4.1 - Living Room Details

Ceiling Damaged

One or more ceilings were damaged or had substandard repairs. Recommend that a qualified person repair as necessary.

Putty knife Drywall Contractor
$
Credit
Comment
13.5.1 - Bathroom Details

Caulking Needed

Gaps, no caulk, or substandard caulking were found where the toilet connects to the floor. Water can penetrate these areas and cause damage. Recommend that a qualified person repair as necessary. For example, by installing or replacing caulk.

Tools Handyman/DIY
$
Credit
Comment
13.7.1 - Interior Electrical

GFCI Issues

One or more ground fault circuit interrupter (GFCI) receptacles (outlets) were not functioning properly (would not trip / would not reset / still energized when tripped). Recommend repairs be made by a qualified licensed electrical contractor. For example, replacing with new GFCI receptacle outlet.

Electric Electrical Contractor
$
Credit
Comment
13.7.2 - Interior Electrical

Receptacle / Switch Loose

One or more electric receptacles, switches and/or the boxes in which they were installed were loose and/or not securely anchored. Wire conductors can be damaged due to repeated movement and/or tension on wires, or insulation can be damaged. This is a shock and fire hazard. Recommend that a qualified electrician repair as necessary.

Electric Electrical Contractor
$
Credit
Comment
13.7.3 - Interior Electrical

Exposed Wire

Contractor Qualified Professional

14 - Electrical

IN NI NP O
14.1 Service X
14.2 GFCI / AFCI Protection- Extended X
14.3 Basement electrical X X
14.4 Panel Photos X
GFCI / AFCI Protection- Extended: GFCI reset locations
N/A
Service: Information
120-240 Voltage
Service: Entrance Conductor Material
Aluminum
Service: Disconnect Amperage

H-100amp, 1 -100amp, 2 -100 amp, 3-100 amp, 4 100 amp

GFCI / AFCI Protection- Extended: GFCI protection present- Extended
Yes

A Ground Fault Circuit Interrupter (GFCI) - Is an ultra sensitive receptacle outlet and/or breaker designed to shut off all electric current. Used in bathrooms, kitchens, exterior waterproof outlets, garage outlets, and "wet areas" to prevent electrical shock. Has a small reset / test button on the receptacle and/or breaker.

GFCI / AFCI Protection- Extended: AFCI protection present- Extended
Yes

An Arc Fault Circuit Interrupter (AFCI) is a circuit breaker that breaks the circuit when it detects an electric arc in the circuit it protects to prevent electrical fires. An AFCI selectively distinguishes between a harmless arc (incidental to normal operation of switches, plugs, and brushed motors), and a potentially dangerous arc (that can occur, for example, in a lamp cord which has a broken conductor).

Panel Photos: Photo

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any time controlled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
14.3.1 - Basement electrical

Switch detached from wall
Basement

Recommend a qualified electrician properly secure the switch to wall

Contractor Qualified Professional

15 - Plumbing

IN NI NP O
15.1 General X
15.2 Main Water Shut-off Device X
15.3 Drain, Waste, & Vent Systems X
15.4 Water Supply, Distribution Systems X X
15.5 Fuel Storage & Distribution Systems X
15.6 Sump Pump X
General: Filters
None
Main Water Shut-off Device: Location Unit 2
Basement
Main Water Shut-off Device: Location Unit 3
Basement
Main Water Shut-off Device: Location Unit 4
Basement
Drain, Waste, & Vent Systems: Drain Size
2"
Drain, Waste, & Vent Systems: Material
PVC, Iron
Water Supply, Distribution Systems: Distribution Material
Pex
Water Supply, Distribution Systems: Water Supply Material
Pex
General: Water Source
Public
Main Water Shut-off Device: Location Unit 1
Basement
Fuel Storage & Distribution Systems: Main Gas Shut-off Location
Gas Meter

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
15.4.1 - Water Supply, Distribution Systems

Water spigot not secure

Water spigot is not secure to the foundation. Recommend anchoring to the foundation.

Contractor Qualified Professional

16 - Garage 1

IN NI NP O
16.1 General X X
16.2 Floors X
16.3 Walls X
16.4 Ceiling X
16.5 Windows X
16.6 Switches / Receptacles X
16.7 GFCI Protection X
16.8 Man Doors X
16.9 Garage Door X
16.10 Lighting & Fans X
16.11 Garage Door Opener X
Floors: Floor Coverings
Concrete
Walls: Wall Material
Brick
Garage Door: Material
Wood
Garage Door: Type
Up-and-Over
General: Garage is full of owners belongings.
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations

17 - Garage 1

IN NI NP O
17.1 General X
17.2 Floors X
17.3 Walls X
17.4 Ceiling X
17.5 Windows X
17.6 Switches / Receptacles X
17.7 GFCI Protection X
17.8 Man Doors X
17.9 Garage Door X
17.10 Lighting & Fans X
17.11 Garage Door Opener X
Floors: Floor Coverings
Concrete
Walls: Wall Material
Brick
Garage Door: Material
Wood
Garage Door: Type
Up-and-Over
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations