Loading
Document Name
Sort Generated Document By
Total Credit Requested
$ 0.00
Preview
Create
Header Text
Total Credit Requested
$ 0.00
Preview
Create
Viewing:

1234 Main St.
Clayton, NC 27527
04/08/2020 9:00AM

Sample agent
agent

Agent Name

Agency Name

1 - Information

Age Of Building (Approximate)
Less than one year
In Attendance
Inspector
Occupancy
Vacant
Stories
2
Temperature (approximate)
55 Fahrenheit (F)
Type of Building
Detached, Single Family
Weather Conditions
Clear
Ground / Soil Condition
Dry

2 - Roof

Coverings: Inspection Method
Walked on Roof
Coverings: Material
Asphalt
Roof Drainage Systems: Gutter Material
Aluminum

3 - Exterior

Siding, Flashing & Trim: Siding Material
Vinyl, Synthetic Adhered Stone Masonry
Walkways, Patios & Driveways: Driveway Material
Concrete
Overhead Doors: Safety Features
Safety Reverse Operational, Photo Lenses Operational
$
Credit
Comment
3.1.1 - Siding, Flashing & Trim

Loose Components

One or more siding components were loose, which could result in moisture intrusion, or in some cases not perform as intended aesthetically. Recommend a qualified siding contractor repair as needed.

$
Credit
Comment
3.2.1 - Walkways, Patios & Driveways

Typical Slab Cracks

There were typical cracks or settlement areas in the slab area.  These cracks are common and normally only are an aesthetic concern.  It is important to prevent water from entering the crevices and contributing to expansion.  We recommend monitoring these areas for further movement, and consulting a structural engineer for a second opinion if so desired. 

4 - HVAC

Cooling: Energy Source
Electric
Cooling: Inspection Method
Visual, Cooling not operated due to exterior temp., No panels were removed
Heating: Energy Source
Electric
Heating: Heat Type
Heat Pump
Heating: Inspection Method
Visual, Panels not removed
Distribution Systems: Ductwork
Insulated
Cooling: Manufacturer
Carrier
Fuel Systems: Main Gas Shut-off Location
Gas Meter
Heating: Manufacturer
Carrier
$
Credit
Comment
4.2.1 - Heating

Condensate Next to Foundation

The condensate line for the HVAC system is draining closely to the foundation or into the crawlspace area.  Over time this could accelerate shifting to surrounding soil and foundation, or build up moisture in the crawlspace .  Recommend a qualified contractor further evaluate and direct water away from the structure.

5 - Interior

Fireplace: Energy Source
Gas
Ceilings / Walls: Material
Wood Framed / Drywall Ceilings & Walls
Fireplace: Not Operated

The fireplace was not operated due to obstruction, lack of access, power, Pilot off, or lack or fuel source.  A full inspection of the system was not performed.  Recommend qualified professional perform inspection to ensure proper operation and ventilation.

6 - Plumbing

Distribution Material
Pex
Water Supply Material
Pex
Drain & Waste Systems: Material
PVC
Hot Water System: Capacity
50 gallons
Hot Water System: Location
Garage
Hot Water System: Power Source
Gas
Main Shut Off
Coat Closet
Hot Water System: Manufacturer
Rheem

7 - Appliances

Dishwasher: Operated
yes
Refrigerator: Inspected
yes
Garbage Disposal: Inspected
Yes
Built-in Microwave: Inspected
yes
Vent Fan : Inspected
yes
Range/Oven/Cooktop: Inspected
yes
$
Credit
Comment
7.5.1 - Built-in Microwave

Improper Mounting

Microwave was improperly mounted above range. Recommend qualified contractor properly secure microwave to prevent damage or injury. 

8 - Attic

Roof Structure: Inspection Method
Entered Attic Access
Roof Structure: Ventilation Type
Ridge Vents, Soffit Vents
Roof Structure: Material
Wood Truss System, OSB Sheathing
Roof Structure: Insulation
Blown

9 - Electrical

Service Entrance / Main & Sub-panels: Electrical Service Conductors
Below Ground, Aluminum
Service Entrance / Main & Sub-panels: Sub & Shut off Panel Locations
Right Exterior, Attic
Service Entrance / Main & Sub-panels: Branch Wiring
Copper, Multi Strand Aluminum
Smoke / Carbon Detectors: Present and Tested?
Yes
Service Entrance / Main & Sub-panels: Main Panel Location / Capacity / Type
Garage, 200 AMP, Circuit Breaker

10 - Crawlspace, Foundation, & Basement

Crawlspace / Basement / Foundation: Inspection Method
Entered Crawlspace Access
Crawlspace / Basement / Foundation: Foundation Type / Material
Masonry Block
Crawlspace / Basement / Foundation: Floor Support & Material
Wood Beams, OSB Sub Floor
Crawlspace / Basement / Foundation: Under Floor Insulation Type
Batt

11 - Ventilation

Ventilation: Dryer Power Source
Electric
Ventilation: Dryer Vent
Metal