1 - Inspection Details

D NP NI IN
1.1 General X
General: In Attendance
N/A
General: Temperature (approximate)
85 Fahrenheit (F)
General: Type of Building
Single Family
General: Weather Conditions
Clear
General: Overview
Inspection Overview

Thank You for choosing Red Carpet Home Inspections to perform your complete home inspection. The goal of this inspection and report is to put you in a better position to make an informed real estate decision. This report is a general guide and provides you with some objection information to help you make your own evaluation of the overall condition of the home and is not intended to reflect the value of the property, or to make any representation as to the advisability of purchase. Not all improvements, defects or hazards will be identified during this inspection. Unexpected repairs should still be anticipated.  This inspection is not a guarantee or warranty of any kind. Red Carpet endeavors to perform all inspections in substantial compliance with InterNACHI's Standards of Practice.  Please refer to the pre-inspection contract for a full explanation of the scope of the inspection. This Home Inspection Report contains observations of those systems and components that, in the professional judgement of the inspector, are not functioning properly, significantly deficient, unsafe, or are near the end of their useful service lives. If the cause for the deficiency is not readily apparent, the suspected cause or reason why the system or component is at or near end of useful service life is reported, and recommendations for correction or monitoring are made as appropriate.  This report is effectively a snapshot of the house recording the conditions on a given date and time. Home inspectors cannot predict future behavior, and as such, we cannot be responsible for things that occur after the inspection.  If conditions change, we are available to revisit the property for an additional charge and update our report.  Any oral statements made by the Inspector pertaining to Recommended Upgrades or any inclusion in the Inspection Report of information regarding Recommended Upgrades shall be deemed to be informational only and supplied as a courtesy to you and shall not be deemed to be an amendment to or waiver of any exclusions included in the "Home Inspection Agreement and Standards of Practice. Any and all recommendations for repair, replacement, evaluation and maintenance issues found should be evaluated by the appropriate trades contractors within the clients inspection contingency window or prior to closing.  This report has been prepared for your exclusive use, as our client. No use by third parties is intended. We will not be responsible to any parties for the contents of the report, other than the part named herein. The report itself is copyrighted, and may not be used in whole or in part without Red Carpet express written permission.  Again, thanks very much for the opportunity to conduct this home inspection for you. We are available to you throughout the entire real estate transaction process. Should you have any questions, please call or email. Sincerely, Aaron Bogans Manager/Certified & Licensed Professional Inspector Red Carpet Home Inspections LLC  Mobile: 540-661-7292 bogans@recarpethomeinspections.com  www.redcarpethomeinspections.com

General: Perspective
Locations

For the purpose of this report, all directional references (Left, Right, Front, Back) are based on when facing the front of the structure as depicted in the cover image above.

General: Use Of Photos
Photos

Your report includes many photographs. Some pictures are intended as a courtesy and are added for your information. Some are to help clarify where the inspector has been, what was looked at, and the condition of the system or component at the time of the inspection. Some of the pictures may be of deficiencies or problem areas, these are to help you better understand what is documented in this report and may allow you to see areas or items that you normally would not see. Not all problem areas or conditions will be supported with photos.

General: Occupancy
Vacant
For furnished homes, access to some items such as electrical outlets, windows, wall/floor surfaces and cabinet interiors can be restricted by furniture and/or personal belongings. These items are limitations of the inspection and these items may be concealed defects.
General: Definitions
Explained

The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any findings / comments that are listed under "Safety / Major" by the inspector suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.Inspected (IN) = The item, component or system was visually inspected and if no other comments were made, then it appeared to be functioning as intended allowing for normal wear and tear.Not Inspected (NI) = The item, component or system was not inspected and no representations made of whether or not it was functioning as intended and will state a reason for not inspecting.Not Present (NP) = The item, component or system is not in this home or building.Observations (O) = The item, component or system was inspected and a concern, observation and/or deficiency was found.

General: Protecting You
Explained

RecallCheck - The first service for consumer recalls in the U.S. has compiled over 225 million recalls from public records, to create a fail-safe system to check for dangerous aws with home appliances.


SewerGard - Covers your water line and sewer line against failure due to normal wear and tear, giving you peace of mind.


Platinum Roof Protection Plan - Handles the repair of leaks to your homes roof for a period of 5 years following the date of inspection


MoldSafe - If you move in to your new home and mold is present that was not found when inspected, youre covered for remediation.


90 Day Warranty - We back all of our inspections with a 90 Day Limited Structural and Mechanical Warranty.


For a period of 90 Days following the inspection or within 22 Days of Closing, whichever comes later. Refer to the complete Terms & Conditions for details and claims procedures. 



  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

2 - Roof

D NP NI IN
2.1 General X
2.2 Coverings X
2.3 Roof Drainage Systems X
2.4 Flashings X X
2.5 Other Roof Penetrations X
2.6 Eaves, Soffits & Fascia X X
2.7 Skylights X
General: Inspection Method
Ladder
General: Roof Type/Style
Gable
Coverings: Inspection Method
Ladder
Coverings: Material
Asphalt
Coverings: Layers
1+ Layer
Coverings: Pitch
Medium
Roof Drainage Systems: Gutter Material
Metal/Aluminum
Roof Drainage Systems: Inspection Method
Ground, Ladder, Roof
Flashings: Inspection Method
Ladder, Roof
Flashings: Material
Rubber
Other Roof Penetrations: Inspection Method
Ladder, Roof
Eaves, Soffits & Fascia: Inspection Method
Ground, Ladder
Eaves, Soffits & Fascia: Material
Wood
Skylights: Inspection Method
N/A
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
2.4.1 - Flashings

Loose/Separated

Flashings observed to be loose or separated, which can lead to water intrusion and/or mold. Recommend a qualified roofing contractor repair.
Roof Roofing Professional
Credit
Comment
2.4.2 - Flashings

Kickout Flashing

As an upgrade, Recommend kickout flashing be installed to divert rain away from sidewall into gutter.

Contractor Qualified Professional

3 - Exterior

D NP NI IN
3.1 Siding, Flashing & Trim X X
3.2 Exterior Doors X
3.3 Exterior Foundation X
3.4 Windows* X X
3.5 Walkways & Driveways X X
3.6 Decks, Patio, Balconies, Porches & Steps X X
3.7 Vegetation, Grading, Drainage & Retaining Walls X X
3.8 Gas Line/Fuel Storage X
Siding, Flashing & Trim: Trim Material
Brick Veneer, Steel/Metal/Aluminum
Siding, Flashing & Trim: Siding Style
Clapboard
Exterior Doors: Exterior Entry Door
North 1st Floor
Steel
Exterior Foundation: Material
Masonry Block
Windows*: Window Type
Single-hung
Windows*: Window Manufacturer
Andersen
Walkways & Driveways: Walkway Material
Concrete
Walkways & Driveways: Driveway Material
Concrete
Decks, Patio, Balconies, Porches & Steps: Stoop/Steps
N/A
Decks, Patio, Balconies, Porches & Steps: Porch
Covered Porch
Decks, Patio, Balconies, Porches & Steps: Patio
N/A
Decks, Patio, Balconies, Porches & Steps: Deck/Balcony
South
Wood
Vegetation, Grading, Drainage & Retaining Walls: Grading
Positive grading
Vegetation, Grading, Drainage & Retaining Walls: Vegetation
Yes
Gas Line/Fuel Storage: Main Gas Shut-off Location
Gas Meter
Windows*: Window Material
North
Wood
Siding, Flashing & Trim: Siding Material
South West East North
Brick Veneer, Steel/Metal/Aluminum

90% covered in Metal siding on the S/E/W sides of the house

10% coverage of brick veneer covering on the N side of the house

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
3.1.1 - Siding, Flashing & Trim

Evidence of Water Intrusion
West

Siding showed signs of water intrusion. This could lead to further siding deterioration and/or mold. Recommend a qualified siding contractor evaluate and repair.
Contractor Qualified Professional
Credit
Comment
3.1.2 - Siding, Flashing & Trim

Damaged Siding
West

Some areas of the siding were damaged. Recommend repair.
Contractor Qualified Professional
Credit
Comment
3.4.1 - Windows*

Damaged Window
North South West East

Contractor Qualified Professional
Credit
Comment
3.5.1 - Walkways & Driveways

Driveway Cracking - Minor

Minor cosmetic cracks observed, which may indicate movement in the soil. Recommend to monitor and/or have concretecontractor patch/seal.
Gardening shovel tool shape Concrete Contractor
Credit
Comment
3.6.1 - Decks, Patio, Balconies, Porches & Steps

Deck - Loose Boards

One or more deck boards were observed to be loose. Recommend they be refastened. Here is a helpful article for minor DIY deck repair.
Tools Handyman/DIY
Credit
Comment
3.6.2 - Decks, Patio, Balconies, Porches & Steps

Deck - Unstable Support
South

One of more areas of the deck support appears unstable. This could cause a safety hazard and further deterioration of the deck. Recommend qualified deck contractor evaluate and repair.
House front 1 Deck Contractor
Credit
Comment
3.6.3 - Decks, Patio, Balconies, Porches & Steps

Improper Deck Construction Practices

Deck was observed to have general poor construction. Recommend qualified deck contractor evaluate.
House front 1 Deck Contractor
Credit
Comment
3.6.4 - Decks, Patio, Balconies, Porches & Steps

Stairs - Deteriorated
South

One or more sections of the exterior stairs are deteriorated. Recommend qualified concrete contractor evaluate & repair.
Contractor Qualified Professional
Credit
Comment
3.7.1 - Vegetation, Grading, Drainage & Retaining Walls

Vegetation Near Home

Recommend to remove vegetation that is in contact with exterior of home.
Wrench DIY

4 - Chimney

D NP NI IN
4.1 General X X
General: Inspection Method
Ladder
General: Exterior Chimney Construction
Masonry
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
4.1.1 - General

Chimney Repointing Needed

Joints in the masonry have deteriorated and should be repointed. (Repointing is the restoration of the mortar joints in the masonry).

Fireplace Chimney Repair Contractor
Credit
Comment
4.1.2 - General

Metal Chimney Rust

The metal chimney shows evidence of rust and/or rusting. Recommend monitoring the chimney which may have to be replaced at some point.

Fireplace Chimney Repair Contractor

5 - Attic, Insulation & Ventilation

D NP NI IN
5.1 General X
5.2 Attic Insulation X X
5.3 Ventilation X X
5.4 Exhaust Systems X X
Attic Insulation: Insulation Type
Batt
Attic Insulation: Depth Of Insulation
12 Inches
Ventilation: Ventilation Type
Gable Vents, Attic Fan
Exhaust Systems: Exhaust Fans
Fan Only
General: Inspection Method
Attic Access
The attic space lacked adequate headroom and a walkway and access was obstructed to most of the attic area. As a result, inspection of the attic was limited. Attics may contain potential fire and/or health hazards, other safety issues, damage or defects that have the potential to cause damage to the home or unexpected repairs. Even when an inspection of the attic is completed from within the attic area, these limitations still exist the same.
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
5.2.1 - Attic Insulation

Staining At Roof Decking

Staining was noted on the attic roof sheathing. This is an indication of excess moisture, either from current or prior leaks, condensation/humidity from lack of adequate ventilation, poorly sealed penetrations from the building envelope such as attic hatches, light fixtures, fan units etc or prior excessive moss.Proper removal/remediation of the dark material is recommended. The actual presence of mold can only be determined by proper testing, which is not a part of this inspection.
Contractor Qualified Professional
Credit
Comment
5.3.1 - Ventilation

Attic Fan Inoperable

Attic fan was inoperable at time of inspection. Recommend an attic fan specialist evaluate and repair.
Contractor Qualified Professional
Credit
Comment
5.3.2 - Ventilation

Gable Vent Damaged

Gable vent was damaged, which could allow pests to enter. Recommend a qualified attic or ventilation contractor repair.
Contractor Qualified Professional
Credit
Comment
5.4.1 - Exhaust Systems

Ducts loose

Ductwork in the attic is loose or disconnected. Recommend repair.
Fire HVAC Professional

6 - Basement, Crawlspace, Foundation

D NP NI IN
6.1 General X
6.2 Interior Foundation X X
6.3 Basements & Crawlspaces X X
6.4 Windows* X X
6.5 Sump Pump X
General: Flooring System
Truss
General: Columns
Wood
Interior Foundation: Material
Concrete
Basements & Crawlspaces: Inspection Method
Within Basement
Windows*: Window Material
Metal
Windows*: Window Type
Single Pane
Windows*: Window Manufacturer
Unknown
Sump Pump: Location
N/A
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
6.3.1 - Basements & Crawlspaces

Mold Like Growth

There are possible signs of fungi growth on ceiling. It is unknown if this is a safety hazard. Recommend a qualified mold inspector evaluate. Evidence of Mold remediation throughout entire basement

Contractor Qualified Professional
Credit
Comment
6.4.1 - Windows*

Damaged
Basement

One or more windows appears to have general damage, but are operational. Recommend a window professional clean, lubricate & adjust as necessary.
Window Window Repair and Installation Contractor

7 - Utility Room

D NP NI IN
7.1 Main Water Shut-off Device X
7.2 Main Water Supply, Distribution Systems X
7.3 Cooling Equipment X
7.4 Cooling Distribution System X
7.5 Cooling Operating Controls X
7.6 Heating Equipment X
7.7 Heating Distribution Systems X
7.8 Heating Operating Controls X
7.9 Hot Water Systems X
7.10 Fuel Storage & Distribution Systems X
Main Water Shut-off Device: Location
Basement
Main Water Shut-off Device: Water Source
Public
Main Water Supply, Distribution Systems: Water Supply Material
Copper/Galvanized
Main Water Supply, Distribution Systems: Distribution Material
Copper
Cooling Equipment: Energy Source/Type
Central Air Conditioner
Cooling Equipment: Brand
Carrier
Cooling Distribution System: Configuration
Central
Cooling Operating Controls: Thermostat Location
Hallway
Heating Equipment: Heat Type
Gas-Fired Heat
Heating Equipment: Energy Source
Natural Gas
Heating Equipment: Brand
Carrier
Heating Distribution Systems: Ductwork
Partially Insulated
Heating Operating Controls: Thermostat Location
Hallway
Hot Water Systems: Power Source/Type
Natural Gas
Hot Water Systems: Capacity
50 gallons
Hot Water Systems: Location
Basement
Fuel Storage & Distribution Systems: Fuel Line Material
Black Iron
Fuel Storage & Distribution Systems: Main Gas Shut-off Location
Gas Meter
Hot Water Systems: Manufacturer
Bradford & White
I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. Here is a nice maintenance guide from Lowe's to help.
Heating Equipment: Too Hot

Temperature  was above the recommended ambient temperature to sufficiently run a heat pump in heating mode

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
7.4.1 - Cooling Distribution System

Ducts Uninsulated

Ducts are not insulated, resulting in energy loss. Recommend licensed HVAC contractor insulate ducts.
Fire HVAC Professional

8 - Fireplace

D NP NI IN
8.1 Heating Device X
8.2 Vents, Flues X
Heating Device: Present
Heating Device: Location
Living Room
Heating Device: Type
Wood
Vents, Flues: Present
Vents, Flues: Types
Flue Liner
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

9 - Garage

D NP NI IN
9.1 General X X
9.2 Roofing X X
9.3 Roof Drainage Systems X X
9.4 Siding, Flashing & Trim X X
9.5 Eaves, Soffits & Fascia X X
9.6 Floor X X
9.7 Fire Separation Walls & Ceiling X
9.8 Electrical & Other X
9.9 Garage Entrance Door X
9.10 Garage Overhead Door X
9.11 Garage Door Opener X
General: Types and Amounts
Carport
Roofing: Material
Asphalt
Roofing: Layers
1+ Layer
Roofing: Pitch
Medium
Roof Drainage Systems: Gutter Material
Metal/Aluminum
Siding, Flashing & Trim: Siding Material
Asphalt
Siding, Flashing & Trim: Trim Material
Asphalt
Eaves, Soffits & Fascia: Material
Asphalt
Floor: Flooring Material
Concrete
Fire Separation Walls & Ceiling: General
Fire Separation Walls & Ceiling: N/A
Electrical & Other: Receptacles
N/A
Electrical & Other: Other
None
Garage Entrance Door: N/A
Garage Overhead Door: Material
N/A
Garage Door Opener: General
Garage Door Opener: Types
N/A
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
9.2.1 - Roofing

Damaged (General)

Roof coverings showed moderate damage. Recommend a qualified roofing professional evaluate and repair.
Roof Roofing Professional
Credit
Comment
9.3.1 - Roof Drainage Systems

Debris

Debris has accumulated in the gutters. Recommend cleaning to facilitate water flow. Here is a DIY resource for cleaning your gutters.
Roof Roofing Professional
Credit
Comment
9.3.2 - Roof Drainage Systems

Downspouts Drain Near Foundation

One or more downspouts drain too close to the foundation which may cause water to enter into the home. Recommend a qualified contractor adjust downspout extensions to drain at least 6 feet from the foundation.
Tools Handyman/DIY
Credit
Comment
9.3.3 - Roof Drainage Systems

Gutter Damaged

Gutters were damaged.This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor evaluate and repair.
Roof Roofing Professional
Credit
Comment
9.3.4 - Roof Drainage Systems

Gutter Loose

The gutter(s) is loose and needs to be re-fastened to fascia and pitched properly.
Wrenches Handyman
Credit
Comment
9.4.1 - Siding, Flashing & Trim

Damaged Siding

One or more pieces of siding were damaged which could result in moisture intrusion. Recommend repair and fasten.
Tools Handyman/DIY
Credit
Comment
9.4.2 - Siding, Flashing & Trim

Damaged Trim

Damaged trim. Recommend repair/replacement.

Contractor Qualified Professional
Credit
Comment
9.5.1 - Eaves, Soffits & Fascia

Eaves - Damaged

One or more sections of the eaves are damaged. Recommend qualified roofer evaluate & repair.
Roof Roofing Professional
Credit
Comment
9.5.2 - Eaves, Soffits & Fascia

Fascia - Damaged

One or more sections of the fascia are damaged. Recommend qualified roofer evaluate & repair.
Roof Roofing Professional
Credit
Comment
9.5.3 - Eaves, Soffits & Fascia

Paint/Finish Failing

The paint or finish is failing. This can lead to deterioration and rot of the material. Recommend that the araes be properly prepared and painted / finished.
Paint roller Painter
Credit
Comment
9.6.1 - Floor

Cracking

Cracking visible in the garage floor. I recommend a structural engineer evaluate.
House construction Structural Engineer

10 - Electrical

D NP NI IN
10.1 General X
10.2 Service Entrance Conductors X
10.3 Main & Subpanels, Service & Grounding, Main Overcurrent Device X
Service Entrance Conductors: Service Entrance
Overhead
Service Entrance Conductors: Conductor Material
Aluminum
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Branch Wiring
Copper
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Amperage
100 AMP
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Voltage
120/240
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Wiring Method
Conduit
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Manufacturer
General Electric
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Type
Circuit Breaker
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Sub Panel Location
None
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main Panel Location
Basement
General: Panel Removed

Front panel cover at electrical panel was removed before the inspection started. Unknown as to who removed it and why.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
10.3.1 - Main & Subpanels, Service & Grounding, Main Overcurrent Device

Electrical System Review

Recommend a licensed electrician review the condition of the electrical wiring throughout the entire home and provide evaluation of findings and recommended repairs.

Electric Electrical Contractor

11 - Kitchen

D NP NI IN
11.1 General X
11.2 Main Water Supply, Distribution Systems X
11.3 Electrical & Other X
11.4 Windows* X
11.5 Dishwasher X
11.6 Refrigerator X
11.7 Garbage Disposal X
11.8 Range/Oven/Cooktop X
11.9 Countertops & Cabinets X
General: General
Main Water Supply, Distribution Systems: Plumbing
Faucets working properly
Main Water Supply, Distribution Systems: Water Supply Material
PVC
Electrical & Other: Receptacles
Operable
Windows*: Window Material
Wood
Windows*: Window Type
Single-hung
Windows*: Window Manufacturer
Andersen
Dishwasher: Brand
GE
Dishwasher: Dishwasher Plumbing
Drain Line Not Looped
Refrigerator: Brand
N/A
Garbage Disposal: Brand
Badger
Range/Oven/Cooktop: Range/Oven Energy Source
Electric
Range/Oven/Cooktop: Range/Oven Brand
Kenmore
Range/Oven/Cooktop: Exhaust Hood Type
None
Countertops & Cabinets: Present
Countertops & Cabinets: Countertop Material
Laminate
Countertops & Cabinets: Cabinetry
Wood

10.1 The inspector shall inspect: F. installed ovens, ranges, surface cooking appliances, microwave ovens, dishwashing machines, and food waste grinders by using normal operating controls to activate the primary function. 10.2 The inspector is NOT required to inspect: G. installed and free-standing kitchen and laundry appliances not listed in Section 10.1.F. H. appliance thermostats including their calibration, adequacy of heating elements, self cleaning oven cycles, indicator lights, door seals, timers, clocks, timed features, and other specialized features of the appliance. I. operate, or con rm the operation of every control and feature of an inspected appliance.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

12 - Living Room

D NP NI IN
12.1 Ceilings X
12.2 Doors X
12.3 Electrical X
12.4 Windows* X
12.5 Floors X
12.6 Walls X
Ceilings: Ceiling Material
Drywall
Electrical: Electrical
Switches, Receptacles
Windows*: Window Material
Wood
Windows*: Window Type
Single-hung
Windows*: Window Manufacturer
Andersen
Floors: Floor Coverings
Carpet
Walls: Wall Material
Drywall
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

13 - Dining Room

D NP NI IN
13.1 Ceilings X
13.2 Doors X
13.3 Electrical X
13.4 Windows* X
13.5 Floors X
13.6 Walls X
Ceilings: Ceiling Material
Drywall
Electrical: Electrical
Switches, Receptacles
Windows*: Window Material
Wood
Windows*: Window Type
Single-hung
Windows*: Window Manufacturer
Andersen
Floors: Floor Coverings
Engineered Wood
Walls: Wall Material
Drywall
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

14 - Laundry Room

D NP NI IN
14.1 General X
14.2 Plumbing & Fixtures X
14.3 Electrical & Other X
14.4 Washer/Dryer X
14.5 Water Supply, Distribution Systems X
General: General
General: Location
N/A
Plumbing & Fixtures: Laundry Sink
No sink
Electrical & Other: Receptacles
Operable
Electrical & Other: Other
None
Washer/Dryer: Dryer Brand
Not Present
Washer/Dryer: Dryer Power Source
N/A
Washer/Dryer: Dryer Vent
N/A
Washer/Dryer: Washer Brand
None
Water Supply, Distribution Systems: Water Supply Material
PVC
Water Supply, Distribution Systems: Distribution Material
PVC
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

15 - Misc. Interior

D NP NI IN
15.1 Steps, Stairways & Railings X
15.2 Smoke Detectors X
15.3 Carbon Monoxide Detectors X
Steps, Stairways & Railings: Location
Hallway

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

16 - Master Bedroom

D NP NI IN
16.1 Ceilings X
16.2 Doors X
16.3 Windows* X
16.4 Electrical X
16.5 Floors X
16.6 Walls X
Ceilings: Ceiling Material
Drywall
Windows*: Window Material
Vinyl
Windows*: Window Type
Double-hung
Windows*: Window Manufacturer
Andersen
Electrical: Electrical
Switches, Receptacles
Floors: Floor Coverings
Carpet
Walls: Wall Material
Drywall
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

17 - Bedroom 2

D NP NI IN
17.1 Present Or Not Present X
17.2 Ceilings X
17.3 Doors X
17.4 Windows* X
17.5 Electrical X
17.6 Floors X
17.7 Walls X
Ceilings: Ceiling Material
South 2nd Floor
Drywall
Windows*: Window Material
Vinyl
Windows*: Window Type
Double-hung
Windows*: Window Manufacturer
Andersen
Windows*: Number of Windows
2
Electrical: Electrical
Switches, Receptacles
Floors: Floor Coverings
Carpet
Walls: Wall Material
Drywall
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
17.5.1 - Electrical

Cover Plates Missing

One or more receptacles are missing a cover plate. This causes short and shock risk. Recommend installation of plates.
Electric Electrical Contractor
Credit
Comment
17.6.1 - Floors

Carpet Stains

Carpet had areas of staining or discoloration. Recommend a thorough steam clean by a qualified carpet cleaning company
Mop Cleaning Service

18 - Bedroom 3

D NP NI IN
18.1 Present Or Not Present X
18.2 Ceilings X
18.3 Doors X
18.4 Windows* X
18.5 Electrical X
18.6 Floors X
18.7 Walls X
Ceilings: Ceiling Material
N/A
Windows*: Window Material
N/A
Windows*: Window Type
N/A
Windows*: Window Manufacturer
N/A
Windows*: Number of Windows
N/A
Electrical: Electrical
N/A
Floors: Floor Coverings
N/A
Walls: Wall Material
N/A
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

19 - Bedroom 4

D NP NI IN
19.1 Present Or Not Present X
19.2 Ceilings X
19.3 Doors X
19.4 Windows* X
19.5 Electrical X
19.6 Floors X
19.7 Walls X
Ceilings: Ceiling Material
N/A
Windows*: Window Material
N/A
Windows*: Window Type
N/A
Windows*: Window Manufacturer
N/A
Electrical: Electrical
N/A
Floors: Floor Coverings
N/A
Walls: Wall Material
N/A
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

20 - Bathroom 1

D NP NI IN
20.1 General X
20.2 Plumbing & Fixtures X
20.3 Electrical & Other X
General: General
Master South
Plumbing & Fixtures: Shower/Tub Material
Ceramic
Plumbing & Fixtures: Water Supply Material
Copper/Galvanized
Plumbing & Fixtures: Distribution Material
Copper
Plumbing & Fixtures: Whirlpool
N/A
Electrical & Other: Receptacles
Master
Operable, GFCI Operable
Electrical & Other: Other
Exhaust Fan Operable
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

21 - Bathroom 2

D NP NI IN
21.1 General X
21.2 Present Or Not Present X
21.3 Plumbing & Fixtures X
21.4 Electrical & Other X
General: General
North 2nd Floor
Plumbing & Fixtures: Shower/Tub Material
None
Plumbing & Fixtures: Water Supply Material
PVC, Copper/Galvanized
Plumbing & Fixtures: Distribution Material
Copper, PVC
Plumbing & Fixtures: Whirlpool
N/A
Electrical & Other: Receptacles
Operable, GFCI Operable
Electrical & Other: Other
Exhaust Fan Not Present
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

22 - Bathroom 3

D NP NI IN
22.1 General X
22.2 Plumbing & Fixtures X
22.3 Electrical & Other X
General: General
Northwest 1st Floor
Plumbing & Fixtures: Shower/Tub Material
None
Plumbing & Fixtures: Water Supply Material
N/A
Plumbing & Fixtures: Distribution Material
N/A
Plumbing & Fixtures: Whirlpool
N/A
Electrical & Other: Receptacles
N/A
Electrical & Other: Other
N/A
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

23 - Bathroom 4

D NP NI IN
23.1 General X
23.2 Plumbing & Fixtures X
23.3 Electrical & Other X
Plumbing & Fixtures: Shower/Tub Material
None, N/A
Plumbing & Fixtures: Water Supply Material
N/A
Plumbing & Fixtures: Distribution Material
N/A
Plumbing & Fixtures: Whirlpool
N/A
Electrical & Other: Receptacles
N/A
Electrical & Other: Other
N/A
  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected