Viewing:

1234 Main St.
Virginia Beach, Virginia 23454
01/23/2020 9:00AM

Sample agent
agent

Agent Name

Agency Name
11
Recommendations
1
Safety hazard

Please review this report in its entirety

1 - Inspection Details

Start Time/End Time

9-10:30

Occupancy
Under Construction
Directional Report Reference(s)
Location(s)/Description(s) are described from a front of home facing point of view.
Type of Building
Detached, Single Family
Temperature (approximate)
80 Fahrenheit (F)
Weather Conditions
Clear, Dry
In Attendance
Client, Client's Agent, Property Manager
Comments

This inspection was requested as a preliminary inspection and was based purely off of visual observations. Some of these items were likely a work in progress.

The items found within your report were considered to be noteworthy. Ensuing inspection upon completion of the home's construction will be much more in depth.

2 - Observations

INSP LI NP O INOP
2.1 Observations/Noteworthy X X
  • INSP = Inspected
  • LI = Limited Inspection
  • NP = Not Present
  • O = Observations
  • INOP = Inoperable
$
Credit
Comment
2.1.1 - Observations/Noteworthy

Damaged Coverings/Loose Nails/No Drip Edge Installed/Rippled Covering/Improper Vent Extension
Roof top

Roof coverings exhibited general damage and wear that appear to be affecting its performance. Recommend a licensed and qualified roofer evaluate and remedy as needed. 

Roof Roofing Professional
$
Credit
Comment
2.1.2 - Observations/Noteworthy

Damaged Tub Bottom
Upstairs Tub

Damage to the upper level tub was observed at the time of inspection. It did not appear as if this would result in a leak. Recommend further evaluation by a licensed and qualified contractor and remedy as needed. 

Contractor Qualified Professional
$
Credit
Comment
2.1.3 - Observations/Noteworthy

Clipped Ground Wire
Below panel interior

The electric panel ground wire was clipped at the time of inspection. Recommend inquiring with builder in regards to planned re-connection and methods to be used. 

Electric Electrical Contractor
$
Credit
Comment
2.1.4 - Observations/Noteworthy

Obstructed Flue
Garage

Flue for planned gas on demand water heater appeared to be obstructed by framing at the time of inspection. Recommend further evaluation by a licensed and qualified plumbing contractor as needed. 

Pipes Plumbing Contractor
$
Credit
Comment
2.1.5 - Observations/Noteworthy

Bowed Wall Framing
Various

Various wall framing studs were visibly warped or bowed at the time of inspection. Recommend further evaluation by a licensed and qualified contractor and advise on course of remedy as needed. 

Contractor Qualified Professional
$
Credit
Comment
2.1.6 - Observations/Noteworthy

Poor construction practices
Lower level rear

Slanted and or separated framing members were observed at the time of inspection. This did not appear to be of a major structural concern however further evaluation is recommended. 

Contractor Qualified Professional
$
Credit
Comment
2.1.7 - Observations/Noteworthy

Knotted Ceiling Joists
Various

Various ceiling joists appeared to be nodded and displayed minor damage. This can result in noisy flooring. This did not appear to be of a major structural concern however further evaluation is recommended. 

Contractor Qualified Professional
$
Credit
Comment
2.1.8 - Observations/Noteworthy

Splayed Cutout Wood
Various

Frayed cut outs were observed surrounding plumbing distribution. This did not appear to be causing any damage to pipes. Recommend removing excess wood from the cut outs as needed does not to be in contact with Plumbing distribution. 

Contractor Qualified Professional
$
Credit
Comment
2.1.9 - Observations/Noteworthy

Damaged slab corner
Lower level pantry area

Damaged slab corner was observed at the time of inspection. This did not appear to have any adverse effect on surrounding structural members. Recommend further evaluation by a licensed and qualified contractor and advise on course of remedy as needed. 

Contractor Qualified Professional
$
Credit
Comment
2.1.10 - Observations/Noteworthy

Missing plates
Various

Missing plates were observed along various areas of wall. These are employed to prevent wire penetration during drywall installation. Recommend evaluation and install as needed prior to continued construction.

Contractor Qualified Professional
$
Credit
Comment
2.1.11 - Observations/Noteworthy

Damaged Flashing Tape
Front

Damaged tape was observed at the time of inspection. Recommend further evaluation and remedy as needed. 

Contractor Qualified Professional
$
Credit
Comment
2.1.12 - Observations/Noteworthy

Damaged Framing
Lower level

Damaged framing was observed within the lower level bathroom at the time of inspection. This did not appear to be a structural member but rather a means to secure plumbing and electrical components. Recommend further evaluation by a licensed and qualified contractor and advise on course of remedy as needed. 

Contractor Qualified Professional