1 - Information

Type of Building
Duplex
Occupancy
Occupied
In Attendance
Tennant
Weather Conditions
Clear
Temp (approx)
Over 90

SCOPE 22 TAC 535.227(a) (1) These standards of practice apply when a professional inspector or real estate inspector who is licensed under this chapter accepts employment to perform a real estate inspection for a prospective buyer or seller of real property. (2) These standards of practice define the minimum requirements for a real estate inspection conducted on a one to four family unit that is substantially completed. Substantially completed means the stage of construction when a new building, addition, improvement, or alteration to an existing building can be occupied or used for its intended purpose . (3) For the purposes of these standards of practice a real estate inspection : (A) is a limited visual survey and basic performance evaluation of the systems and components of a building using normal controls that provides information regarding the general condition of a residence at the time of inspection; (B) is not intended to be a comprehensive investigation or exploratory probe to determine the cause or effect of deficiencies noted by the inspector; and (C) does not require the use of: (i) specialized equipment, including but not limited to : (I) thermal imaging equipment; (II) moisture meters; (III) gas or carbon monoxide detection equipment; (IV) environmental testing equipment and devices; (V) elevation determination devices; or (VI) ladders capable of reaching surfaces over one story above ground surfaces; or (ii) specialized procedures, including but not limited to: (I) environmental testing; (II) elevation measurement; (III) calculations; or (IV) any method employing destructive testing that damages otherwise sound materials or finishes. (4) These standards of practice do not prohibit an inspector from providing a higher level of inspection performance than required by these standards of practice or from inspecting components and systems in addition to those listed under the standards of practice. DEFINITIONS 22 TAC 535.227(b) (1) Accessible -In the reasonable judgment of the inspector, capable of being approached, entered, or viewed without: (A) hazard to the inspector; (B) having to climb over obstacles, moving furnishings or large, heavy, or fragile objects; (C) using specialized equipment or procedures; (D) disassembling items other than covers or panels intended to be removed for inspection; (E) damaging property, permanent construction or building finish; or (F) using a ladder for portions of the inspection other than the roof or attic space. (2) Chapter 1102 - Texas Occupations Code, Chapter 1102. (3) Component - A part of a system. (4) Cosmetic - Related only to appearance or aesthetics, and not related to performance, operability, or water penetration. (5) Deficiency - In the reasonable judgment of the inspector, a condition that: (A) adversely and materially affects the performance of a system, or component; or (B) constitutes a hazard to life, limb, or property as specified by these standards of practice. (6) Deficient--Reported as having one or more deficiencies. (7) Inspect - To operate in normal ranges using ordinary controls at typical settings, look at and examine accessible systems or components and report observed deficiencies as specified by these standards of practice. (8) Performance - Achievement of an operation, function or configuration relative to accepted industry standard practices with consideration of age and normal wear and tear from ordinary use. (9) Report - To provide the inspector's opinions and findings on the standard inspection report form as required by 535.222 and 535.223 of this title. (10)Standards of practice - 535.227 - 535.233 of this title. GENERAL REQUIREMENTS 22 TAC 535.227(c) The inspector shall: (1) operate fixed or installed equipment and appliances listed herein in at least one mode with ordinary controls at typical settings; (2) visually inspect accessible systems or components from near proximity to the systems and components, and from the interior of the attic and crawl spaces; and (3) complete the standard inspection report form as required by 535.222 and 535.223 of this title. GENERAL LIMITATIONS 22 TAC 535.227(d) The inspector is not required to: (1) inspect: (A) items other than those listed within these standards of practice; (B) elevators; (C) detached buildings, decks, docks, fences, or waterfront structures or related equipment; (D) anything buried, hidden, latent, or concealed; (E) sub-surface drainage systems; (F) automated or programmable control systems, automatic shut-off, photoelectric sensors, timers, clocks, metering devices, signal lights, lightning arrestor system, remote controls, security or data distribution systems, solar panels or smart home automation components; or (G) concrete flatwork such as driveways, sidewalks, walkways, paving stones or patios; (2) report: (A) past repairs that appear to be effective and workmanlike except as specifically required by these standards; (B) cosmetic or aesthetic conditions; or (C) wear and tear from ordinary use; (3) determine: (A) the presence or absence of pests, termites, or other wood-destroying insects or organisms; (B) the presence, absence, or risk of: (i) asbestos; (ii) lead-based paint; (iii) mold, mildew; (iv) corrosive or contaminated drywall "Chinese Drywall"; or (v) any other environmental hazard, environmental pathogen, carcinogen, toxin, mycotoxin, pollutant, fungal presence or activity, or poison; (C) types of wood or preservative treatment and fastener compatibility; or (D) the cause or source of a condition; (E) the cause or effect of deficiencies; (F) any of the following issues concerning a system or component: (i) insurability or warrantability; (ii) suitability, adequacy, compatibility, capacity, reliability, marketability, or operating costs; (iii) recalls, counterfeit products, or product lawsuits; (iv) life expectancy or age; (v) energy efficiency, vapor barriers, or thermostatic performance; (vi) compliance with any code, listing, testing or protocol authority; (vii) utility sources; or (viii)manufacturer or regulatory requirements, except as specifically required by these standards; (4) anticipate future events or conditions, including but not limited to: (A) decay, deterioration, or damage that may occur after the inspection; (B) deficiencies from abuse, misuse or lack of use; (C) changes in performance of any component or system due to changes in use or occupancy; (D) the consequences of the inspection or its effects on current or future buyers and sellers; (E) common household accidents, personal injury, or death; (F) the presence of water penetrations; or (G) future performance of any item; (5) operate shut-off, safety, stop, pressure or pressure-regulating valves or items requiring the use of codes, keys, combinations, or similar devices; (6) designate conditions as safe; (7) recommend or provide engineering, architectural, appraisal, mitigation, physical surveying, realty, or other specialist services; (8) review historical records, installation instructions, repair plans, cost estimates, disclosure documents, or other reports; (9) verify sizing, efficiency, or adequacy of the ground surface drainage system; (10) verify sizing, efficiency, or adequacy of the gutter and downspout system; (11) operate recirculation or sump pumps; (12) remedy conditions preventing inspection of any item; (13) apply open flame or light a pilot to operate any appliance; (14) turn on decommissioned equipment, systems or utility services; or (15) provide repair cost estimates, recommendations, or re-inspection services. CONFLICTS 22 TAC 535.227(e) In the event of a conflict between the general provisions set out in this section, and specific provisions specified elsewhere in the standards of practice, specific provisions shall take precedence. DEPARTURE PROVISION 22 TAC 535.227(f) (1) An inspector may depart from the inspection of a component or system required by the standards of practice only if: (A) the inspector and client agree the item is not to be inspected; (B) the inspector is not qualified to inspect the item; (C) in the reasonable judgment of the inspector, the inspector determines that: (i) conditions exist that prevent inspection of an item; (ii) conditions or materials are hazardous to the health or safety of the inspector; or (iii) the actions of the inspector may cause damage to the property (D) the item is a common element of a multifamily development and is not in physical contact with the unit being inspected, such as the foundation under another building or a part of the foundation under another unit in the same building. (2) If an inspector departs from the inspection of a component or system required by the standards of practice, the inspector shall: (A) notify the client at the earliest practical opportunity that the component or system will not be inspected; and (B) make an appropriate notation on the inspection report form, stating the reason the component or system was not inspected. (3) If the inspector routinely departs from inspection of a component or system required by the standards of practice, and the inspector has reason to believe that the property being inspected includes that component or system, the earliest practical opportunity for the notice required by this subsection is the first contact the inspector makes with the prospective client.  ENFORCEMENT 22 TAC 535.227(g) Enforcement. Failure to comply with the standards of practice is grounds for disciplinary action as prescribed by Chapter 1102.

2 - I. Structural Systems

IN NI NP D
2.1 A. Foundations X X
2.2 B. Grading and Drainage X X
2.3 C. Roof Covering Materials X X
2.4 D. Roof Structure & Attic X
2.5 E. Walls (Interior and Exterior) X X
2.6 F. Ceilings and Floors X X
2.7 G. Doors (Interior and Exterior) X X
2.8 H. Windows X X
2.9 I. Stairways (Interior and Exterior) X
2.10 J. Fireplaces and Chimneys X X
2.11 K. Porches, Balconies, Decks, and Carports X X
2.12 L. Other X X
A. Foundations: Type of Foundation(s)
Slab on Grade
A. Foundations: Crawl space viewed from
No crawl space
A. Foundations: Performance Opinion
C. Roof Covering Materials: Types of Roof Covering
Composition
C. Roof Covering Materials: Viewed From
Roof
C. Roof Covering Materials: Water Penetrations
Present
C. Roof Covering Materials: Prior Repairs
Present
D. Roof Structure & Attic: Viewed From
MAster closet of both units but only 7483 was accessible, From the scuttle opening
D. Roof Structure & Attic: Average Attic Floor Insulation Depth
7-10, Unknown
D. Roof Structure & Attic: Water Penetrations
Present
D. Roof Structure & Attic: Framing Type
No access
D. Roof Structure & Attic: Vertical Insulation Thickness
Not visible (one story)
D. Roof Structure & Attic: Insulation Types
Unable to determine
E. Walls (Interior and Exterior): Comments
E. Walls (Interior and Exterior): Material
Brick
F. Ceilings and Floors: Comments
F. Ceilings and Floors: Ceiling Type
Drywall
F. Ceilings and Floors: Floor Type
Vinyl, Carpet
G. Doors (Interior and Exterior): Comments
H. Windows: Comments
I. Stairways (Interior and Exterior): Comments
J. Fireplaces and Chimneys: Comments
K. Porches, Balconies, Decks, and Carports: Comments
Inspector Opinion

All of the information contained herein is the opinion of the inspector, at the time of the inspection.  Conditions may change.  

A. Foundations: Comments:
  • Any foundation deficiencies listed below in this section should be further evaluated by a Licensed Engineer of your choosing. Any deficiencies with regard to exposed cables or drainage problems should be further evaluated and corrected as necessary by a qualified contractor.

B. Grading and Drainage: Comments
  • Any grade or drainage deficiencies listed below in this section should be further evaluated and corrected as necessary by a qualified contractor.

B. Grading and Drainage: *Drainage
  • Proper grading and drainage are required to maintain proper foundation performance and prevent water penetration, which is a conducive condition for wood rot, wood destroying insect intrusion and possible mold growth.


B. Grading and Drainage: Marginal Site Drainage
7483 back
  • Marginal site drainage was observed. Proper drainage is needed to help prevent water from standing and/or ponding next to the foundation beam. Corrective measures may be needed if the water stands within 10-feet of the foundation perimeter beam for more than 24-hours.

C. Roof Covering Materials: Comments
  • Any roof covering deficiencies listed below in this section should be further evaluated the homeowners insurance company and or a qualified roofing contractor; and any necessary repairs should be corrected as necessary by a qualified roofing contractor.

C. Roof Covering Materials: Pics for referance

Pictures if the roof covering for reference. 

C. Roof Covering Materials: Trim Trees (too close)
  • Tree and shrub branches need to be trimmed away from the roofig material at all times to help prevent damage to the roofing material. It is the opinion of this Inspector that there are some branches too close to the roofing material at this time and corrective measures are needed.

D. Roof Structure & Attic: Comments
  • Any roof structure, Attic ladder, ventilation, insulation, gutters or soffit & fascia deficiencies listed below in this section should be further evaluated corrected as necessary by a qualified contractor.

D. Roof Structure & Attic: Roof structure good.
  • The roof structural components appeared to be in satisfactory condition at the time of this inspection. No corrective actions are recommended at this time. 
E. Walls (Interior and Exterior): Method

The inspection of interior and exterior walls focuses on structural performance and water penetration issues. The condition of surface finishes and cosmetic blemishes are not noted, except where they may contribute to or be symptomatic of other problems. Areas within finished walls and concealed flashing details (e.g. doors, windows, brick ledges, etc.) are not accessible and beyond the scope of the inspection. Home furnishings, artwork, stored goods, heavy foliage, etc. can obscure damage, water stains, previous repairs, etc., and preclude assessment of these conditions.

As a matter of general home maintenance, it is recommended that all deficiencies in the "exterior envelope" be sealed for energy efficiency and to help prevent water and moisture penetration into the structure. Examples would be caulking doors/windows, replacing worn weather-strip seals, and sealing wall penetrations or openings (around light fixtures, a/c lines etc.)

E. Walls (Interior and Exterior): Needs Paint

The exterior wood surfaces need a fresh coat of paint.  Proper care of exterior wood can play a significant role in preventing damage.


F. Ceilings and Floors: Signs of Prior Repairs
7483 front bedroom

Signs of precious paint or texture touch ups were observed on the ceilings. 

G. Doors (Interior and Exterior): Method of Inspection

The interior and exterior doors are inspected for proper function including latches and locking mechanisms. Garage doors are inspected for proper operation.

H. Windows: Method

Windows, where accessible, are inspected for proper function including latches and locking mechanisms. Broken panes, broken thermal seals, missing or damaged screens and caulking deficiencies are noted. Safety issues safety glass in required locations and egress issues in sleeping areas are noted.

I. Stairways (Interior and Exterior): Method

The inspection of the stairways is a visual observation of the required component's and focuses on handrails, spindles, railings, and guards etc. The inspector does not exhaustively measure every stairway component.

J. Fireplaces and Chimneys: Flue OK
7483

The visible portion of the flue appeared to be in satisfactory condition at the time of this inspection. 

J. Fireplaces and Chimneys: Fireplace OK
7483

Picture of the fireplace during operation. The fireplace appeared to be performing properly at the time of this inspection. 

K. Porches, Balconies, Decks, and Carports: Method

Porches, decks, driveways and carport's are visually inspected for structural defects and safety related deficiencies (e.g. cracks, trip hazards, negative slope towards the structure, differential movement, etc.).

A. Foundations: Client Notice

Notice: This inspection is one of first impression and the inspector was not provided with any historical information pertaining to the structural integrity of the inspected real property. This is a limited cursory and visual survey of the accessible general conditions and circumstances present at the time of this inspection. Opinions are based on general observations made without the use of specialized tools or procedures. Therefore, the opinions expressed are one of apparent conditions and not of absolute fact and are only good for the date and time of this inspection. The inspection of the foundation may show it to be providing adequate support for the structure or having movement typical to this region, at the time of the inspection. This does not guarantee the future life or failure of the foundation. The Inspector is not a structural engineer. This inspection is not an engineering report or evaluation and should not be considered one, either expressed or implied. If any cause of concern is noted on this report, or if you want further evaluation, you should consider an evaluation by an engineer of your choice. 

  • Foundation inspections are limited to observation of accessible interior and exterior structural components.  No engineering studies or measurements are made.  Factors preventing accurate assessment of structural conditions include but are not limited to paint, repairs, surfaces hidden by floor or wall coverings, furnishings, foliage, and masonry.
B. Grading and Drainage: Method
  • General lot drainage and slope is inspected by visual means only (no measuring devices are used-such means and devices are beyond the scope of our inspection). The findings are, to a great extent, subjective. Our evaluation of the slope of the grade and lot drainage is a visal review and represents the opinion of the inspector based on his personal experience with similar homes. The inspection does not predict or guarantee future performance. If actual measurements and a professional drainage evaluation are desired, a qualified engineer should be consulted.

Inspection of the homes grading and drainage is done by a visual observation of the site around the structure, including surface grade, rain gutters and down spouts, etc. Any visible conditions or symptoms that may indicate a situation that may adversely affect the foundation or indicate water penetration are noted. No soil, topographical or flood plain studies are performed.



C. Roof Covering Materials: Limitation

Roof inspections are limited to visual observations of the accessible surfaces. The roof is inspected from the roof level, only if in the opinion of the inspector it can be done safely and without damaging the roof. Certain types of damage and/or poor workmanship (e.g., improper fastening, manufacturer defects, improper installation etc) may not be apparent during the visual inspection. As such the inspector cannot guarantee that the roof will be free of leaks, nor can the inspector determine the remaining service life of the roof covering. If deficiencies are noted and/or you have concerns about life expectancy, insurability or potential for future problems, we Highly recommend consulting with a Qualified roofing Contractor prior to the expiration of any warranty or option period.  

C. Roof Covering Materials: Life Expectancy

Notice: Life expectancy of the roofing material is not covered by this property inspection report.  If any concerns exist about the roof covering life expectancy or potential for future problems, a roofing specialist should be consulted.  The Inspector cannot offer an opinion or warranty as to whether the roof has leaked in the past, leaks now, or may be subject to future leaks, either expressed or implied.  
The inspection of this roof may show it to be functioning as intended or in need of minor repairs. This inspection does not determine the insurability of the roof. You are strongly encouraged to have your Insurance Company physically inspect the roof, prior to the expiration of any time limitations such as option or warranty periods, to fully evaluate the insurability of the roof.

D. Roof Structure & Attic: Roof Structure Limitations
  • Inspection of the roof structure and attic is performed by a visual observation of areas and components which can be reasonably and safely accessed. Areas where insulation is covering joists and no visible pathway could be identified will not be traversed

E. Walls (Interior and Exterior): General Limitations

In accordance with industry standards, the inspection is limited to only those surfaces that are exposed and readily accessible. The Inspector does not move furniture, lift floor-covering materials, or remove or rearrange items within closets or on shelving. On your final walk through, or at some point after furniture and personal belongings have been removed, it is important that you inspect the interior portions of the residence that were concealed or otherwise inaccessible at the time of the inspection. Contact the Inspector immediately if any adverse conditions are observed that were not commented on in your inspection report.


In the event the residence was furnished at the time of the inspection and portions of the interior were hidden by the occupant's belongings. In accordance with industry standards, the inspection is limited to only those surfaces that are exposed and readily accessible. The Inspector does not move furniture, lift floor-covering materials, or remove or rearrange items within closets or on shelving. On your final walk through, or at some point after furniture and personal belongings have been removed, it is important that you inspect the interior portions of the residence that were concealed or otherwise inaccessible at the time of the inspection. Contact the Inspector immediately if any adverse conditions are observed that were not commented on in your inspection report.


F. Ceilings and Floors: Ceiling and Floor Limitations

Inspection of ceilings and floors focuses on structural performance and water penetration issues. The condition of surface finishes and cosmetic blemishes are not noted, except where they may contribute to or be symptomatic of other problems. Areas concealed within finished spaces are not accessible and are beyond the scope of an inspection. Home furnishings, artwork, personal items, etc. can obscure damage, water stains, previous repairs, etc., and prevent assessment in these areas.

H. Windows: Occupied

I was unable to inspect the operation of some of the windows due to window treatments, personal effects, large, heavy or fragile storage and/or furniture.

H. Windows: Dirty

windows were dirty at the time of inspection. It is more difficult to find fogged windows when windows are dirty. 

J. Fireplaces and Chimneys: General

Examination of concealed or inaccessible portions of the chimney is beyond the scope of our inspection. We do not perform draft or smoke tests. If further review is desired, we recommend consulting with a qualified contractor.

FOUNDATIONS 22 TAC 535.228(a) (1) The inspector shall: (A) render a written opinion as to the performance of the foundation; and (B) report: (i) the type of foundations; (ii) the vantage point from which the crawl space was inspected; (C) report present and visible indications of adverse performance of the foundation, such as: (i) binding, out-of-square, or non-latching doors; (ii) framing or frieze board separations; (iii) sloping floors; (iv) window, wall, floor, or ceiling cracks or separations; and (v) rotating, buckling, cracking, or deflecting masonry cladding. (D) report as Deficient: (i) deteriorated materials; (ii) deficiencies in foundation components such as; beams, joists, bridging, blocking, piers, posts, pilings, columns, sills or subfloor; (iii) deficiencies in retaining walls related to foundation performance; (iv) exposed or damaged reinforcement; (v) crawl space ventilation that is not performing; and (vi) crawl space drainage that is not performing. (2) The inspector is not required to: (A) enter a crawl space or any area where headroom is less than 18 inches or the access opening is less than 24 inches wide and 18 inches high; (B) provide an exhaustive list of indicators of possible adverse performance; or (C) inspect retaining walls not related to foundation performance.


GRADING AND DRAINAGE 22 TAC 535.228(b) (1) The inspector shall report as Deficient: (A) drainage around the foundation that is not performing; (B) deficiencies in grade levels around the foundation; and (C) deficiencies in installed gutter and downspout systems. (2) The inspector is not required to: (A) inspect flatwork or detention/retention ponds (except as related to slope and drainage); (B) determine area hydrology or the presence of underground water; or (C) determine the efficiency or performance of underground or surface drainage systems.


ROOF COVERING MATERIALS 22 TAC 535.228(c) (1) The inspector shall: (A) inspect the roof covering materials from the surface of the roof; (B) report: (i) type of roof coverings; (ii) vantage point from where the roof was inspected; (iii) evidence of water penetration; (iv) evidence of previous repairs to the roof covering material, flashing details, skylights and other roof penetrations; and (C) report as Deficient deficiencies in: (i) fasteners; (ii) adhesion; (iii) roof covering materials; (iv) flashing details; (v) skylights; and (vi) other roof penetrations. (2) The inspector is not required to: (A) inspect the roof from the roof level if, in the inspector's reasonable judgment, the inspector: (i) cannot safely reach or stay on the roof; or (ii) significant damage to the roof covering materials may result from walking on the roof; (B) determine: (i) the remaining life expectancy of the roof covering; or (ii) the number of layers of roof covering material; (C) identify latent hail damage; (D) exhaustively examine all fasteners and adhesion, or (E) provide an exhaustive list of locations of deficiencies and water penetrations.


ROOF STRUCTURES AND ATTICS 22 TAC 535.228(d) (1) The inspector shall: (A) report: (i) the vantage point from which the attic space was inspected; (ii) approximate average depth of attic insulation; (iii) evidence of water penetration; (B) report as Deficient: (i) attic space ventilation that is not performing; (ii) deflections or depressions in the roof surface as related to adverse performance of the framing and decking; (iii) missing insulation; (iv) deficiencies in (I) installed framing members and decking; (II) attic access ladders and access openings; and (III) attic ventilators. (2) The inspector is not required to: (A) enter attics or unfinished spaces where openings are less than 22 inches by 30 inches or headroom is less than 30 inches; (B) operate powered ventilators; or (C) provide an exhaustive list of locations of deficiencies and water penetrations.


INTERIOR WALLS, CEILINGS, FLOORS, AND DOORS 22 TAC 535.228(e) (1) The inspector shall: (A) report evidence of water penetration; (B) report as Deficient: (i) deficiencies in the condition and performance of doors and hardware; (ii) deficiencies related to structural performance or water penetration; and (iii) the absence of or deficiencies in fire separation between the garage and the living space and between the garage and its attic. (2) The inspector is not required to: (A) report cosmetic damage or the condition of floor, wall, or ceiling coverings; paints, stains, or other surface coatings; cabinets; or countertops, or (B) provide an exhaustive list of locations of deficiencies and water penetrations.


EXTERIOR WALLS, DOORS, AND WINDOWS 22 TAC 535.228(f) (1) The inspector shall: (A) report evidence of water penetration; (B) report as Deficient: (i) the absence of performing emergency escape and rescue openings in all sleeping rooms; (ii) a solid wood door less than 1-3/8 inches in thickness, a solid or honeycomb core steel door less than 1-3/8 inches thick, or a 20-minute fire-rated door between the residence and an attached garage; (iii) missing or damaged screens; (iv) deficiencies related to structural performance or water penetration; (v) deficiencies in: (I) weather stripping, gaskets or other air barrier materials; (II) claddings; (III) water resistant materials and coatings; (IV) flashing details and terminations; (V) the condition and performance of exterior doors, garage doors and hardware; and (VI) the condition and performance of windows and components. (2) The inspector is not required to: (A) report the condition of awnings, blinds, shutters, security devices, or other nonstructural systems; (B) determine the cosmetic condition of paints, stains, or other surface coatings; or (C) operate a lock if the key is not available. (D) provide an exhaustive list of locations of deficiencies and water penetrations.


EXTERIOR AND INTERIOR GLAZING 22 TAC 535.228(g) (1) The inspector shall report as Deficient: (A) insulated windows that are obviously fogged or display other evidence of broken seals; (B) deficiencies in glazing, weather stripping and glazing compound in windows and doors; and (C) the absence of safety glass in hazardous locations.(2) The inspector is not required to: (A) exhaustively inspect insulated windows for evidence of broken seals; (B) exhaustively inspect glazing for identifying labels; or (C) identify specific locations of damage.


INTERIOR AND EXTERIOR STAIRWAYS 22 TAC 535.228(h) (1) The inspector shall report as Deficient: (A) spacing between intermediate balusters, spindles, or rails for steps, stairways, guards, and railings that permit passage of an object greater than 4 inches in diameter, except that on the open side of the staircase treads, spheres less than 4-3/8 inches in diameter may pass through the guard rail balusters or spindles; and (B) deficiencies in steps, stairways, landings, guardrails, and handrails. (2) The inspector is not required to exhaustively measure every stairway component.


FIREPLACES AND CHIMNEYS 22 TAC 535.228(i) (1) The inspector shall report as Deficient: (A) built-up creosote in accessible areas of the firebox and flue; (B) the presence of combustible materials in near proximity to the firebox opening; (C) the absence of fireblocking at the attic penetration of the chimney flue, where accessible; and (D) deficiencies in the: (i) damper; (ii) lintel, hearth, hearth extension, and firebox; (iii) gas valve and location; (iv) circulating fan; (v) combustion air vents; and (vi) chimney structure, termination, coping, crown, caps, and spark arrestor. (2) The inspector is not required to: (A) verify the integrity of the flue; (B) perform a chimney smoke test; or (C) determine the adequacy of the draft.


PORCHES, BALCONIES, DECKS AND CARPORTS 22 TAC 535.228(j) (1) The inspector shall: (A) inspect: (i) attached balconies, carports, and porches; (ii) abutting porches, decks, and balconies that are used for ingress and egress; and (B) report as Deficient: (i) on decks 30 inches or higher above the adjacent grade, spacings between intermediate balusters, spindles, or rails that permit passage of an object greater than four inches in diameter; and (ii) deficiencies in accessible components. (2) The inspector is not required to: (A) exhaustively measure every porch, balcony, deck, or attached carport components; or (B) enter any area where headroom is less than 18 inches or the access opening is less than 24 inches wide and 18 inches high.



  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
2.1.1 - A. Foundations

**Visual Needs Further Evaluation

In my opinion, the slopes in the foundation are above acceptable tolerance for slope in a foundation and or the stress indicators (Cracks etc...) appear to be more than normal.. Further evaluation is  recommended.


Recommendations:

  • It is recommended that the foundation be evaluated by a Licensed engineer and repaired if necessary per the engineers recommendations by a qualified foundation contractor.
  • It is recommended that a sub-surface drain leak test be performed by a licensed plumbing contractor. If a leak is found it is recommended that the leak be fixed.
  • Maintain a watering program throughout the year to prevent the soil around the home from drying and cracking. If soaker hoses are used, place the soaker hoses 1'  2' away from the foundation and run for 30  60 minutes every other day as needed. Do not over water the foundation; this can be as detrimental as under watering.

The following observations if noted, would support the rendering of this opinion.  

  • Brick/Mortar cracks observed in the exterior veneer.
  • Misalignment of interior doors.
  • Interior door(s) stick and/or not closing.
  • Separations of the exterior veneer and window / door frames. 
  • Frieze board separations.
  • Cracks in the floor / foundation.
  • Floor slopes and/or not level.  
  • Stress crack(s) in the exterior foundation perimeter beam.
  • Interior drywall cracks or  stress indicators.
  • Other indicators as noted by Inspector.




Qualified Professional
$
Credit
Comment
2.1.2 - A. Foundations

Exposed Cable Ends
Left side & right side & back

  • Exposed post tension cable ends were observed at the exterior of the home. It is recommended that the metal cables be painted (rust inhibiting paint)  and then the slab should be patched. The slab patch / mortar should be used in conjunction with a bonding agent that helps it bond to the old concrete.

Concrete Contractor
$
Credit
Comment
2.2.1 - B. Grading and Drainage

Negative Grading
7485 back

Grading is sloping towards the home in some areas. This could lead to water intrusion and foundation issues. Recommend qualified landscaper or foundation contractor regrade so water flows away from home.

Here is a helpful article discussing negative grading. 

Grading Contractor
$
Credit
Comment
2.3.1 - C. Roof Covering Materials

Damaged shingles
front

  • Damaged shingles were observed at the time of inspection.  All damaged shingles should be replaced. 
Roofing Professional
$
Credit
Comment
2.3.2 - C. Roof Covering Materials

Evidence of leaks
IN the front bedroom of 7483 and the hallway bathroom of 7483

  • Visible evidence of leaks were observed. Recommend a qualified roofer evaluate and repair. 
Roofing Professional
$
Credit
Comment
2.3.3 - C. Roof Covering Materials

Lifted Shingles
Near the left chimney

The roofing material observed to have loose and/or lifting shingles in various locations.  The damage may have been caused by a previous wind storm and should be further evaluated.


Roofing Professional
$
Credit
Comment
2.3.4 - C. Roof Covering Materials

Decking Soft / Crackling

  • The decking was observed to make crackling noises when walking on the roof. When the decking starts to make those types of noises the decking has become weaker. It is recommended that the buyer budget for new decking the next time the roof is replaced. When I walked the roof I tried to stay of the rafters for safety reasons. 
Roofing Professional
$
Credit
Comment
2.3.5 - C. Roof Covering Materials

Wrong type of roof caps

The roof caps for the dryer vents, water heaters or bathroom exhaust fans are no longer approved as vent caps the gaps atound the cap are too large and could allow pests to enter the vent. This type of cap was allowed years ago but no longer. it is recommended that a appoved cap be installed at all vecessay vents.

Roofing Professional
$
Credit
Comment
2.4.1 - D. Roof Structure & Attic

Soffit damaged
front, rear left side and right side

  • Damage to the soffit or fascia of the home was observed at the time of this inspection. It is rexommended that the damaged soffit / fascia board be replaced, resealed and properly painted. 
Qualified Professional
$
Credit
Comment
2.4.2 - D. Roof Structure & Attic

No access
Unit 7485

There was no access to the attic at the time of inspection. Belongings or storage were in the way.

DIY
$
Credit
Comment
2.5.1 - E. Walls (Interior and Exterior)

Seal Penetrations

The area between the exterior veneer and any wall penetration needs to be properly sealed. 

 It is recommended to use elastomeric caulking.

Handyman/DIY
$
Credit
Comment
2.5.2 - E. Walls (Interior and Exterior)

Seal Transition

The transition from wood veneer to brick veneer needs to be better sealed.

Handyman/DIY
$
Credit
Comment
2.5.3 - E. Walls (Interior and Exterior)

Drywall Cracks
7485- front entry & livingroom & 7483 front bedroom, family room and master bedroom

There are a number of cracks in the interior walls that are considered to be cosmetic and average for  the age of the home.  .  No attempt is made to discover or document an exhaustive list of every crack or anomaly in the interior. These deficiencies should be repaired the next time the interior is painted.

Painting Contractor
$
Credit
Comment
2.5.4 - E. Walls (Interior and Exterior)

Water Stain on Wall

Water stains were observed on the walls   The cause and remedy should be further evaluated and corrected as necessary. All water damaged building materials should be replaced.


Drywall Contractor
$
Credit
Comment
2.5.5 - E. Walls (Interior and Exterior)

Holes in wall

Holes in the wall should be repaired by a qualified contractor. 

Qualified Professional
$
Credit
Comment
2.5.6 - E. Walls (Interior and Exterior)

Wood destroying insects damage
7485 &

• Apparent damage from wood destroying insects was observed. All damaged wood should be replaced and the home should be checked by a wood destroying insect specialist and treated as necessary. 

Qualified Professional
$
Credit
Comment
2.5.7 - E. Walls (Interior and Exterior)

Sound coat paint

• Exterior wood surfaces need caulking at joints and a sound coat of paint. All deteriorated wood should be replaced. 

Qualified Professional
$
Credit
Comment
2.5.8 - E. Walls (Interior and Exterior)

Door boarded up

the back yard closet door was missing and boarded up with plywood. I could not see into the closet and check for damage.

Qualified Professional
$
Credit
Comment
2.6.1 - F. Ceilings and Floors

Water Stain
7483 front bedroom closet & hallbath

Water stains were observed on the ceiling finish. The cause and remedy should be further evaluated and corrected as necessary.

Handyman/DIY
$
Credit
Comment
2.6.2 - F. Ceilings and Floors

Worn Floor Covering
7485 kitchen & master bath

The floor covering is noticeably worn and/or damaged in one or more locations of the home.

Flooring Contractor
$
Credit
Comment
2.6.3 - F. Ceilings and Floors

Carpet stain
7485 throughout home

carpet was observed to be stained at the time of inspection and should be cleaned as necessary. 

Qualified Professional
$
Credit
Comment
2.7.1 - G. Doors (Interior and Exterior)

Door Sticks
7483 front bedroom & 7483 front bedroom closet & 7485 front entry & back yard closet &

The door is sticking.

Door Repair and Installation Contractor
$
Credit
Comment
2.7.2 - G. Doors (Interior and Exterior)

Surface Damage
7485 master bedroom, master closet

The door has some surface damage.

Door Repair and Installation Contractor
$
Credit
Comment
2.7.3 - G. Doors (Interior and Exterior)

Light visible.
Right side exterior door 7485

Light was observed to be visible between the door jamb and the exterior door. The weatherstripping should be adjusted or replaced.

Qualified Professional
$
Credit
Comment
2.7.4 - G. Doors (Interior and Exterior)

Forced entry

• Signs of forced entry were observed at one or more doors. The door should be replaced. 

Qualified Professional
$
Credit
Comment
2.7.5 - G. Doors (Interior and Exterior)

Wood rot
7485 back and right side

Wood rot observed at one of the exterior doors. All deteriorated components should be replaced. 

Qualified Professional
$
Credit
Comment
2.7.6 - G. Doors (Interior and Exterior)

Loose hardware
7483 side door

• Door handle loose and should be resecured. 

Qualified Professional
$
Credit
Comment
2.7.7 - G. Doors (Interior and Exterior)

Delaminating
7483 masterbedroom

One of the doors was delaminating and needs to be replaced. 

Qualified Professional
$
Credit
Comment
2.8.1 - H. Windows

Window Stiff
Front bedroom

One or more of the windows were observed to be stiff and hard to operate.

Window Repair and Installation Contractor
$
Credit
Comment
2.8.2 - H. Windows

Missing / Damaged Screen

One or more of the window screens were observed to be missing or damaged.

Window Repair and Installation Contractor
$
Credit
Comment
2.10.1 - J. Fireplaces and Chimneys

Furniture in the way
7485

The fireplace could not be inspected because furniture was in the way

Qualified Professional
$
Credit
Comment
2.11.1 - K. Porches, Balconies, Decks, and Carports

Major Driveway Cracks

Larger than typical cracks and/or deficiencies were observed in the driveway. Any areas where the cracks present a trip hazard should be replaced sfor safety reasons.

Concrete Contractor
$
Credit
Comment
2.12.1 - L. Other

Fence post damage

Some deterioration and/or damage was observed on the fence support posts.

Fence Contractor
$
Credit
Comment
2.12.2 - L. Other

Fence Rail damage

Some deteriorate and/or damage was observed on the fence rails.

Fence Contractor
$
Credit
Comment
2.12.3 - L. Other

Fence board damage

Some deterioration and/or damage was observed on the fence boards.

Fence Contractor

3 - II. Electrical Systems

IN NI NP D
3.1 A. Service Entrance and Panels X X
3.2 B. Branch Circuits, Connected Devices, and Fixtures X X
A. Service Entrance and Panels: Comments
A. Service Entrance and Panels: Electric Panel Rating
150
A. Service Entrance and Panels: Electric Panel location
Master bedroom
B. Branch Circuits, Connected Devices, and Fixtures: Type of Wiring
Copper
B. Branch Circuits, Connected Devices, and Fixtures: Comments
Overview

A typical electrical system consists of two distinct components (1) The electric service entrance (e.g. underground or overhead). Underground the conductors are underground and are not visible for observation. Overhead service comes in from the utility pole to a service mast and down to the electrical meter. (2) Service Panel. The service panel determines the capacity of the electric power to the home. The circuits within the service panel distribute the power throughout the home.

A. Service Entrance and Panels: 3 Pics for Reference:
7485
  • Picture of the panel with the cover on for reference.
  • Picture of the electrical service panel with the cover removed for reference.
  • I checked the electrical service panel with an IR (InfraRed) camera looking for any overheating components in the panel.  


A. Service Entrance and Panels: 3 Pics for Reference:
  • Picture of the panel with the cover on for reference.
  • Picture of the electrical service panel with the cover removed for reference.
  • I checked the electrical service panel with an IR (InfraRed) camera looking for any overheating components in the panel.  


General

Inspection of the electrical service system is limited to visible and accessible components of the entrance cables, meter box, service panel and the visible portions of the wiring. The majority of the electrical system is concealed behind walls and ceilings and conditions relating to these inaccessible areas can not be determined. Whenever possible, the dead front cover for the service panel will be removed to investigate the condition of the wiring and circuits. While some deficiencies in an electrical system may be apparent, not all conditions that can lead to an interruption of electrical service, or that may be hazardous, can be identified through a visual inspection. No assessment as to the adequacy of the service capacity relative to current or future consumption is performed. Inspector is seldom able to locate/identify proper grounding and/or bonding. If buyer desires more information, further evaluation by a licensed electrician is advised. 

A. Service Entrance and Panels: General

Not all electrical components are visible to the inspector. The inspector will report deficiencies that are visible at the time of the inspection.  If deficiencies are noted, or if there are any questions or concerns you are advised to have a licensed electrician fully evaluate the homes electrical system prior to the expiration of any warranty or option period.   

B. Branch Circuits, Connected Devices, and Fixtures: General

Electrical devices in a home typically use either 120 or 240 volt electricity. General purpose circuits (lighting, receptacles, fans, etc.) require 120 volts. The major appliances such as clothes dryers, kitchen ranges, electric water heaters, air conditioners, and electric heating units require 240 volts. Inspection of the electrical distribution system is limited to the visible and accessible components of the distribution wiring, receptacles, switches and other connected devices. The majority of the electrical distribution system is concealed behind walls and ceilings and their conditions are not known. The lack of GFCI, protection in presently required locations regardless of the homes age are noted, as required by the Texas Real Estate Commission. Low voltage and ancillary electrical systems such as landscape lighting, generators, etc. are not inspected. Inspection of the doorbells and chimes is limited to testing the operation of the chimes and the physical condition, function, and installation of the doorbell button. Inspection and testing of Intercom systems are not included in this inspection.

In furnished homes all switches and receptacles may not be accessible for inspection or testing.  Receptacles located in garage ceilings and exterior soffits are not individually tested.


B. Branch Circuits, Connected Devices, and Fixtures: Low voltage X inspected

Inspection of low-voltage or decorative lighting lies beyond the scope of the General Home Inspection.
You may wish to have the functionality of any such lighting demonstrated by the seller.

B. Branch Circuits, Connected Devices, and Fixtures: Smoke Detectors

Smoke Detectors
Today's standards require smoke detectors in each bedroom and outside each separate sleeping area on every level of the structure. Smoke detectors should be located on the ceilings at least 18" away from the wall. (Smoke tends to mushroom upward, turning outward toward the center of the ceiling. To Fire Fighters this is known as the mushroom effect, which leaves a dead airspace 18" from a ceiling to a wall corner). Test all alarms weekly or monthly per manufacturers recommendations.  Failure to test, repair defective or install absent alarms, detectors and other safety equipment immediately can result in serious injury or death. Initiate and practice plans of escape and protection for all occupants in case any emergency arises.
 Smoke detectors are tested using the manufacturer supplied test button only. This inspection does not include testing smoke detectors with actual smoke.

B. Branch Circuits, Connected Devices, and Fixtures: Carbon Monoxide Alarms

Carbon Monoxide Alarms
Smoke is heated and rises, thus smoke detectors are placed on the ceiling.  Carbon Monoxide, on the other hand, mixes with our air, and stays closer to the ground.  For this reason it is advised that CO detectors should be mounted at Knee Height (nose level for the average person sleeping).  The Center for Disease Control (CDC) recommends replacing CO alarms every 5 years.   Carbon Monoxide Alarms are tested with the manufacturer test button only. 

B. Branch Circuits, Connected Devices, and Fixtures: Unable to determine switch operation

I was unable to determine the operation end of one or more of the switches.

SERVICE ENTRANCE AND PANELS 22 TAC 535.229 (a) (1) The inspector shall report as Deficient: (A) a drop, weatherhead or mast that is not securely fastened to the building; (B) the absence of or deficiencies in the grounding electrode system; (C) missing or damaged dead fronts or covers plates; (D) conductors not protected from the edges of electrical cabinets, gutters, or cutout boxes; (E) electrical cabinets and panel boards not appropriate for their location; such as a clothes closet, bathrooms or where they are exposed to physical damage; (F) electrical cabinets and panel boards that are not accessible or do not have a minimum of 36-inches of clearance in front of them; (G) deficiencies in: (i) electrical cabinets, gutters, cutout boxes, and panel boards; (ii) the insulation of the service entrance conductors, drip loop, separation of conductors at weatherheads, and clearances; (iii) the compatibility of overcurrent devices and conductors; (iv) the overcurrent device and circuit for labeled and listed 240 volt appliances; (v) bonding and grounding; (vi) conductors; (vii) the operation of installed ground-fault or arc-fault circuit interrupter devices; and (H) the absence of: (i) trip ties on 240 volt overcurrent devices or multi-wire branch circuit; (ii) appropriate connections; (iii) anti-oxidants on aluminum conductor terminations; (iv) a main disconnecting means. (2) The inspector is not required to: (A) determine present or future sufficiency of service capacity amperage, voltage, or the capacity of the electrical system; (B) test arc-fault circuit interrupter devices when the property is occupied or damage to personal property may result, in the inspector's reasonable judgment; (C) conduct voltage drop calculations; (D) determine the accuracy of overcurrent device labeling; (E) remove covers where hazardous as judged by the inspector; (F) verify the effectiveness of overcurrent devices; or (G) operate overcurrent devices.


BRANCH CIRCUITS, CONNECTED DEVICES, AND FIXTURES 22 TAC 535.229 (b) (1) The inspector shall: (A) manually test the installed and accessible smoke and carbon monoxide alarms; (B) report the type of branch circuit conductors; (C) report as Deficient: (i) the absence of ground-fault circuit interrupter protection in all: (I) bathroom receptacles; (II) garage receptacles; (III) outdoor receptacles; (IV) crawl space receptacles; (V) unfinished basement receptacles; (VI) kitchen countertop receptacles; and (VII)receptacles that are located within six feet of the outside edge of a sink; (ii) the failure of operation of ground-fault circuit interrupter protection devices; (iii) missing or damaged receptacle, switch or junction box covers; (iv) the absence of: (I) equipment disconnects; (II) appropriate connections, such as copper/aluminum approved devices, if branch circuit aluminum conductors are discovered in the main or sub-panel based on a random sampling of accessible receptacles and switches; (v) appliances and metal pipes that are not bonded or grounded; (vi) deficiencies in: (I) receptacles; (II) switches; (III) wiring, wiring terminations, junction boxes, devices, and fixtures, including improper location; (IV) doorbell and chime components; (V) smoke and carbon monoxide alarms; (vii) improper use of extension cords; (viii) deficiencies in or absences of conduit, where applicable; and \ (ix) the absence of smoke alarms: (I) in each sleeping room; (II) outside each separate sleeping area

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
3.1.1 - A. Service Entrance and Panels

IR check Too Hot
7485

  • I checked the electrical panel with the IR camera to see if there were any overheating problems and found excessive heat readings at the time of this inspection.  This condition should be further evaluated and corrected as necessary by a licensed electrician Prior to Closing.

Qualified Professional
$
Credit
Comment
3.1.2 - A. Service Entrance and Panels

Cover Screw Missing
7485

One or more of the cabinet cover plate screws are missing and need to be replaced.  Only blunt tipped screws should be used for safety reasons.

Electrical Contractor
$
Credit
Comment
3.2.1 - B. Branch Circuits, Connected Devices, and Fixtures

GFCI Missing
7485 & 7483 exterior, kitchen, bathrooms

Not all of the receptacles in the wet/damp areas appear to have ground fault circuit interrupter (GFCI) protection. Under current electrical standards all of the exterior receptacles, all kitchen receptacles, all bathroom receptacles, wet bar countertop receptacles, laundry room receptacles, garage non-appliance dedicated receptacles and pool lighting should have GFCI protection.  This is an as-built condition, but Per TREC standards of practice we are required to report this condition as a deficiency. Some items reported as Deficient may be considered upgrades to the property. For more information, refer to Texas Real Estate Consumer Notice Concerning Recognized Hazards, form OP-I.

Electrical Contractor
$
Credit
Comment
3.2.2 - B. Branch Circuits, Connected Devices, and Fixtures

Loose Plug
Front porch 7485 & 7483 family room

One or more of the receptacles were observed to be loose at the wall mount

Electrical Contractor
$
Credit
Comment
3.2.3 - B. Branch Circuits, Connected Devices, and Fixtures

Closet light no cover

One or more of the closet light fixtures appear to be installed without globes and/or covers.  Safety precautions should be taken around these light fixtures. This is an as built condition however we are required by TREC to note this as a deficiency. 

Handyman/DIY
$
Credit
Comment
3.2.4 - B. Branch Circuits, Connected Devices, and Fixtures

Exterior light damaged
7485 exterior right

One or more of the exterior light fixtures were observed to be damaged.

Handyman/DIY
$
Credit
Comment
3.2.5 - B. Branch Circuits, Connected Devices, and Fixtures

Bulb?

One or more of the light fixtures appear to be inoperative.  This may be due to a bad bulb or some other unknown condition. This condition should be further evaluated and corrected as necessary.

DIY
$
Credit
Comment
3.2.6 - B. Branch Circuits, Connected Devices, and Fixtures

Light INOP
Living Room 7485

One or more of the light fixtures were observed to be inoperative.

Electrical Contractor
$
Credit
Comment
3.2.7 - B. Branch Circuits, Connected Devices, and Fixtures

Not interconnected

One or more of the smoke alarms do not appear to be interconnected together. Under today's building standards: When more than one smoke alarm is required to be installed within an individual dwelling unit the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual unit. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed.

Handyman/DIY
$
Credit
Comment
3.2.8 - B. Branch Circuits, Connected Devices, and Fixtures

no respond

One or more of the smoke alarms did not respond properly when tested.

Handyman/DIY
$
Credit
Comment
3.2.9 - B. Branch Circuits, Connected Devices, and Fixtures

No op end

I was not able to determine the operational end of some of the homes switches

Qualified Professional
$
Credit
Comment
3.2.10 - B. Branch Circuits, Connected Devices, and Fixtures

Handyman wiring

• Handyman wiring observed above hange hood.

Electrical Contractor
$
Credit
Comment
3.2.11 - B. Branch Circuits, Connected Devices, and Fixtures

Fixture missing
hallway near front bedroom in 7485

light fixture missing.

Electrical Contractor
$
Credit
Comment
3.2.12 - B. Branch Circuits, Connected Devices, and Fixtures

Missing weather cover
front porch 7483

A weather resistant cover was missing or damaged at the time of inspection and should be replaced/installed. 

Electrical Contractor
$
Credit
Comment
3.2.13 - B. Branch Circuits, Connected Devices, and Fixtures

Fan not balanced
7483 family room

• The ceiling fan shakes and needs to be balanced. 

Electrical Contractor

4 - III. Heating, Ventilation & Air Conditioning Systems

IN NI NP D
4.1 A. Heating Equipment X X
4.2 B. Cooling Equipment X X
4.3 C. Duct System, Chases, and Vents X X
A. Heating Equipment: Type of System
Forced Air
A. Heating Equipment: Energy Source
Electric
A. Heating Equipment: Comments
A. Heating Equipment: Furnace unit
Goodman, Trane
B. Cooling Equipment: Type of System
Central
B. Cooling Equipment: Comments
B. Cooling Equipment: AC Unit Information
Goodman, Trane, 2 Ton, Temp differential 15, Temp differential 23 or greater, Max 30 amp breaker
C. Duct System, Chases, and Vents: Comments
HVAC Inspection

The inspector will identify the type of HVAC system present and what source(s) of energy is used.  The HVAC system will be operated and checked for proper operation. The location of the HVAC system and clearances as required will also be identified. The flue pipe (if present) will be inspected for condition and proper clearances as required. Gas lines are checked for leaks at the connections and correct installation methods.

Note: When D (D = Deficient) is checked, that indicates that the HVAC system does not appear to be performing as intended. The observations made to support the rendering of this opinion are listed in this report.  This list should not be considered an all inclusive list of deficiencies.  You are advised to have a fully qualified and licensed HVAC service provider perform a  full evaluation of  this HVAC system equipment and repair any and all deficiencies that are found prior to the expiration of any warranty or option period .  

A. Heating Equipment: Too Hot

The operation of the heating system was not checked due to the outside ambient temperature being above 90 Degrees. If any concerns exist about the future operation of the heating equipment, then it is recommended that a Qualified HVAC Technician further inspect and give an evaluation on the operation of the equipment and any further concerns that may exist with this equipment.
At the time, a limited visual inspection will be performed and if any defects are found they will be listed in this section.

B. Cooling Equipment: RLA draw and Pics of Inside & Outside
7485
  • The RLA (Running Load Amps)   The unit drew 8.4_ amps. This rough check is within the normal operating range.
  • Picture of the cooling equipment in the atticHVAC closet for your reference.
  • Picture of the outside condensing unit for reference.

B. Cooling Equipment: RLA draw and Pics of Inside & Outside
7483
  • The RLA (Running Load Amps)  The unit drew 8.39 amps. This rough check is within the normal operating range.
  • Picture of the cooling equipment in the atticHVAC closet for your reference.
  • Picture of the outside condensing unit for reference.

B. Cooling Equipment: Temps measured
7483

All HVAC supply grills were checked with an IR camera to make sure air was flowing to all rooms.  The temperature drop was greater than normal by one degree but the filter was dirty. The filter should be replaced and the temperatures rechecked by a licensed HVAC technician.

B. Cooling Equipment: Temps measured
7485

All HVAC supply grills were checked with an IR camera to make sure air was flowing to all rooms.  These temps ar inside the acceptable tange 15-22 degrees

C. Duct System, Chases, and Vents: Picture of the Filter
  • Picture of the HVAC filter for reference.  FYI: 1 inch filters should be changed Every month and 4 inch filters should be changed every three months  as part of regular home maintenance.
C. Duct System, Chases, and Vents: Ductwork ok
  • All visible ducts appeared to be in satisfactory condition at the time of this inspection.   None of the ductwork was visible for unit 7485 because there was No attic access. The ductwork that was visible above unit 7483 appeared to be in satisfactory condition.
Inspection Method

This inspection is a visual observation of components present at the time of the inspection. We do not dismantle components. Current day heat exchangers are sealed units and are not visible for inspection. Heat Pumps are not operated when outdoor temperatures are above 60 degrees due to damage that may occur to the heat pump system

B. Cooling Equipment: Visual observation

A visual observation of all accessible components are inspected. The cooling system will be checked for correct operation. A measurement of the Delta-T checked at the return and supply air vents only will be measured. The cooling equipment will not be operated when the outdoor temperatures fall below 60 degrees due to damage that may occur to the cooling equipment during operation.


C. Duct System, Chases, and Vents: General

Some of the duct work is in areas of the attic that are not readily accessible.  Not all of the duct work is visible.  Some duct work, by design, is hidden in the walls and ceilings.  Only visible ductwork is inspected.

HEATING EQUIPMENT 22 TAC 535.230(a) (1) General requirements. (A) The inspector shall report: (i) the type of heating systems; (ii) the energy sources; (B) The inspector shall report as Deficient: (i) inoperative units; (ii) deficiencies in the thermostats; (iii) inappropriate location; (iv) the lack of protection from physical damage; (v) burners, burner ignition devices or heating elements, switches, and thermostats that are not a minimum of 18 inches above the lowest garage floor elevation, unless the unit is listed for garage floor installation; (vi) the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish; (vii) when applicable; a floored passageway and service platform that would allow access for equipment inspection, service, repair or replacement; (viii) deficiencies in mounting and performance of window and wall units; (2) Requirements for electric heating units, the inspector shall report deficiencies in: (A) performance of heat pumps; (B) performance of heating elements; and (C) condition of conductors; and (3) Requirements for gas heating units, the inspector shall report as Deficient: (A) gas leaks; (B) flame impingement, uplifting flame, improper flame color, or excessive scale buildup; (C) the absence of a gas shut-off valve within six feet of the appliance; (D) the absence of a gas appliance connector or one that exceeds six feet in length; (E) gas appliance connectors that are concealed within or extended through walls, floors, partitions, ceilings or appliance housings; and (F) deficiencies in: (i) combustion, and dilution air; (ii) gas shut-off valves; (iii) access to a gas shutoff valves that prohibits full operation; (iv) gas appliance connector materials; and (v) the vent pipe, draft hood, draft, proximity to combustibles, and vent termination point and clearances; and COOLING EQUIPMENT 22 TAC 535.230(b) (1) Requirements for cooling units other than evaporative cooler. (A) The inspector shall report the type of systems; (B) The inspector shall report as Deficient: (i) inoperative units; (ii) inadequate cooling as demonstrated by its performance; (iii) the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish; (iv) when applicable; a floored passageway and service platform that would allow access for equipment inspection, service, repair or replacement; (v) noticeable vibration of blowers or fans; (vi) water in the auxiliary/secondary drain pan; (vii) a primary drain pipe that discharges in a sewer vent; (viii)missing or deficient refrigerant pipe insulation; (ix) dirty coils, where accessible; (x) condensing units lacking adequate clearances or air circulation or that has deficiencies in the fins, location, levelness, or elevation above grade surfaces; (xi) deficiencies in: (I) the condensate drain and auxiliary/ secondary pan and drain system; (II) mounting and performance of window or wall units; and (III) thermostats. (2) Requirements for evaporative coolers. (A) The inspector shall report: (i) type of systems; (ii) the type of water supply line; (B) The inspector shall report as Deficient: (i) inoperative units; (ii) inadequate access and clearances; (iii) deficiencies in performance or mounting; (iv) missing or damaged components; (v) the presence of active water leaks; and (vi) the absence of backflow prevention. DUCT SYSTEMS, CHASES, AND VENTS 22 TAC 535.230(c) (1) The inspector shall report as Deficient: (A) damaged duct systems or improper material; (B) damaged or missing duct insulation; (C) the absence of air flow at accessible supply registers; (D) the presence of gas piping and sewer vents concealed in ducts, plenums and chases; (E) ducts or plenums in contact with earth; and (2) The inspector shall report as Deficient deficiencies in: (A) filters; (B) grills or registers; and (C) the location of return air openings. GENERAL LIMITATIONS 22 TAC 535.230(d) For heating, ventilation, and air conditioning systems inspected under this section, the inspector is not required to perform the following actions: (1) program digital thermostats or controls; (2) inspect: (A) for pressure of the system refrigerant, type of refrigerant, or refrigerant leaks; (B) winterized or decommissioned equipment; or (C) duct fans, humidifiers, dehumidifiers, air purifiers, motorized dampers, electronic air filters, multi-stage controllers, sequencers, heat reclaimers, wood burning stoves, boilers, oil-fired units, supplemental heating appliances, de-icing provisions, or reversing valves; (3) operate: (A) setback features on thermostats or controls; (B) cooling equipment when the outdoor temperature is less than 60 degrees Fahrenheit; (C) radiant heaters, steam heat systems, or unvented gas-fired heating appliances; or (D) heat pumps, in the heat pump mode, when the outdoor temperature is above 70 degrees; (4) verify: (A) compatibility of components; (B) tonnage match of indoor coils and outside coils or condensing units; (C) the accuracy of thermostats; or (D) the integrity of the heat exchanger; or (5) determine: (A) sizing, efficiency, or adequacy of the system; (B) balanced air flow of the conditioned air to the various parts of the building; or (C) types of materials contained in insulation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
4.1.1 - A. Heating Equipment

Blower not balanced
7483

  • The inside portion of the HVAC equipment (HVAC closet/Attic) appeared to have some uneven vibration. It is recommended that the blower motor be checked by a licensed HVAC technician to see if it needs cleaning and or balancing.

HVAC Professional
$
Credit
Comment
4.2.1 - B. Cooling Equipment

Dirty filter
7483

Note: The filter in unit 7483 was dirty on the day of inspection. This condition can slow down the air flow and make the temperature differential better than during proper operation.



DIY
$
Credit
Comment
4.2.2 - B. Cooling Equipment

No filter Check Evap Coil

  • The equipment was observed to have a filter that was too small allowing air to bypass the filter on the day of inspection. I am not able to determine how long the equipment has gone without a properly sized  filter. This condition can lead to dust, dog hair etc.. to build up on the evaporator coil. This condition should be evaluated and corrected as necessary by a licensed HVAC technician.

Qualified Professional
$
Credit
Comment
4.2.3 - B. Cooling Equipment

Temp Drop TOO High
7483

  • The temperature drop measured of the air conditioning system is greater than considered normal.  This indicates that airflow across the evaporator coil is too low.  Low airflow could be the result of a dirty filter, dirty or obstructed evaporator coil fins, or insufficient blower and/or ductwork sizing.  This condition can lead to ice build-up on the coil.  A qualified heating and cooling technician should be consulted Prior to Closing to further evaluate this condition and the remedies available for correction. The filter should be replaced and the temperatures rechecked.

Qualified Professional
$
Credit
Comment
4.2.4 - B. Cooling Equipment

Level outside unit
7483

The outdoor unit of the air conditioning system is out of level.  It is recommended that the outside condenser/coils be within 1-inch of level.

Qualified Professional
$
Credit
Comment
4.3.1 - C. Duct System, Chases, and Vents

Dirty register

The air-registers for the HVAC system appear to be dirty and should be cleaned to help maintain good air quality.  This is typically an indication of a dirty HVAC filter.

Qualified Professional
$
Credit
Comment
4.3.2 - C. Duct System, Chases, and Vents

Dirty Filters
7483

The filters were dirty at the time of inspection and should be replaced as necessary. 1 in filters should be replaced monthly and 4 in filters should be replaced every 3 months.

Qualified Professional
$
Credit
Comment
4.3.3 - C. Duct System, Chases, and Vents

Filter too small

• the AC filter was observed to be too small and air was bypassing the filter. The proper size filter should be installed and replaced monthly

Qualified Professional

5 - IV. Plumbing Systems

IN NI NP D
5.1 A. Plumbing Supply, Distribution Systems, and Fixtures X X
5.2 B. Drains, Wastes, & Vents X X
5.3 C. Water Heating Equipment X
5.4 D. Hydro-Massage Therapy Equipment X
A. Plumbing Supply, Distribution Systems, and Fixtures: Comments
C. Water Heating Equipment: Water Heater
I dont know where they are. I inspected both condos and did not find the water heaters
C. Water Heating Equipment: Comments
D. Hydro-Massage Therapy Equipment: Comments
Location of Water Meter
Near the Street in front of the home
  • I observed the water meter for some time looking for signs of a leak.
Location of Customer Shutoff Valve
The front flowerbed
  • The home inspector does not attempt to operate the customer shutoff valve. Operating a water valve that has not been used in a long time can cause the valve to leak.
Static Water Pressure
70-80

FYI: Water pressure can fluctuate from day to day and change with seasons! Normal operating range for water pressure is from 40 PSI to 80 PSI.

Comments
  • Any Plumbing deficiencies listed below in this section should be further evaluated corrected as necessary by a Licensed Plumber.
  • The sink drains were tested in every wet area with a sink Any leaks or improper installations will be listed below. The tubs were partially filled and the drains were tested in all areas with tubs any slow draining tubs will be listed below in the drains section of the report.


PICS Water Pressure, Meter & Customer Shutoff
  • Picture of the pressure gauge at the time of inspection.
  • Picture of the water meter at the time of inspection.
  • If discoverable a picture of the customer shutoff valve.


A. Plumbing Supply, Distribution Systems, and Fixtures: Protect hose bibb from freezing
  • The exterior water hose bibbs / faucets adjacent to the home should be protected from physical damage and/or possible freeze during the time of year when temperatures drop below freezing.

A. Plumbing Supply, Distribution Systems, and Fixtures: Pic of the laundry connections
  • Picture of the laundry room washer box connections. No rust or leaks were found at the time of this inspection.
B. Drains, Wastes, & Vents: Comments
  • Plumbing deficiencies listed below in this section should be further evaluated corrected as necessary by a Licensed Plumber.

C. Water Heating Equipment: general

Water Heaters should be flushed every year or as recommended by the manufacturer to remove sediments that collect at the bottom of the tank. This can be accomplished by attaching a garden hose to the drain valve at the bottom of the heater, directing the discharge water to a safe location and turning the valve on. Caution should be observed as the water coming out will be very hot. The flush is complete when the water comes out clear.


The T & P Valve (Temperature & Pressure Release Valve) should be tested annually for reasons of safety. Follow the manufacturers instructions for testing procedures.


We highly recommend the use of a water alarm at the water heater.  This alarm will sound at the presence of any water leaks and could help prevent major water intrusion events due to failure of the water heater.  These units are available online or at major home improvement centers for about $10 each.

C. Water Heating Equipment: Working OK
  • Pictures of the fixtures taken with an IR camera. The water heater appears to be heating properly at the time of this inspection. I never found the water heaters but the water was hot and the corrected sides of the tubs and sinks and there was no hot water at the toilets
General
  • Laundry connection faucets and drains are visually inspected only. The laundry faucets are not operated due to the damage that may occur during testing. 
  • The refrigerator water supply line and valve are not inspected.  If the inspector finds the water supply valve shutoff to any appliance, no attempt is made to turn the supply on.  
  • The hot & cold water valves are NOT tested underneath sinks or commodes in  the home. Testing shutoff valves can often times cause them to leak.

B. Drains, Wastes, & Vents: Tub and washer
  • Tub overflow drains are not inspected or tested. Showers were run for an extended period of time. The clothes washer drain line was not inspected or tested at the time of the inspection.

PLUMBING SYSTEMS 22 TAC 535.231(a) (1)The inspector shall: (A) report: (i) location of water meter; (ii) location of homeowners main water supply shutoff valve; and (iii) static water pressure; (B) report as Deficient: (i) the presence of active leaks; (ii) water pressure in excess of 80 PSI; (iii) the lack of a pressure reducing valve when the water pressure exceeds 80 PSI; (iv) the lack of an expansion tank at the water heater(s) when a pressure reducing valve is in place at the water supply line/system, unless the pressure reducing valve automatically allows for thermal expansion; (v) the absence of: (I) fixture shut-off valves; (II) dielectric unions, when applicable; (III) back-flow devices, anti-siphon devices, or air gaps at the flow end of fixtures; and (vi) deficiencies in: (I) water supply pipes and waste pipes; (II) the installation and termination of the vent system; (III) the performance of fixtures and faucets not connected to an appliance; (IV) water supply, as determined by viewing functional flow in two fixtures operated simultaneously; (V) fixture drain performance; (VI) orientation of hot and cold faucets; (VII) installed mechanical drain stops; (VIII) commodes, fixtures, showers, tubs, and enclosures; and (IX) the condition of the gas distribution system. (2) The inspector is not required to: (A) operate any main, branch, or shut-off valves; (B) operate or inspect sump pumps or waste ejector pumps; (C) verify the performance of: (i) the bathtub overflow; (ii) clothes washing machine drains or hose bibbs; or (iii) floor drains; (D) inspect: (i) any system that has been winterized, shut down or otherwise secured; (ii) circulating pumps, free-standing appliances, solar water heating systems, waterconditioning equipment, filter systems, water mains, private water supply systems, water wells, pressure tanks, sprinkler systems, swimming pools, or fire sprinkler systems; (iii) inaccessible gas supply system components for leaks; (iv) for sewer clean-outs; or (v) for the presence or performance of private sewage disposal systems; or (E) determine: (i) quality, potability, or volume of the water supply; or (ii) effectiveness of backflow or antisiphon devices. WATER HEATERS 22 TAC 535.231(b) (1) General requirements. (A) The inspector shall: (i) report: (I) the energy source; (II) the capacity of the units; (ii) report as Deficient: (I) inoperative units; (II) leaking or corroded fittings or tanks; (III) damaged or missing components; (IV) the absence of a cold water shutoff valve; (V) if applicable, the absence of a pan or a pan drain system that does not terminate over a waste receptor or to the exterior of the building above the ground surface; (VI) inappropriate locations; (VII) the lack of protection from physical damage; (VIII) burners, burner ignition devices or heating elements, switches, or thermostats that are not a minimum of 18 inches above the lowest garage floor elevation, unless the unit is listed for garage floor installation; (IX) the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish; (X) when applicable; a floored passageway and service platform that would allow access for equipment inspection, service, repair or replacement; (XI) the absence of or deficiencies in the temperature and pressure relief valve and discharge piping; (XII) a temperature and pressure relief valve that failed to operate, when tested manually; (B) The inspector is not required to: (i) verify the effectiveness of the temperature and pressure relief valve, discharge piping, or pan drain pipes; (ii) operate the temperature and pressure relief valve if the operation of the valve may, in the inspector's reasonable judgment, cause damage to persons or property; or (iii) determine the efficiency or adequacy of the unit. (2) Requirements for electric units, the inspector shall report deficiencies in: (A) performance of heating elements; and (B) condition of conductors; and (3) Requirements for gas units, the inspector shall report as Deficient: (A) gas leaks; (B) flame impingement, uplifting flame, improper flame color, or excessive scale build-up; (C) the absence of a gas shut-off valve within six feet of the appliance; (D) the absence of a gas appliance connector or one that exceeds six feet in length; (E) gas appliance connectors that are concealed within or extended through walls, floors, partitions, ceilings or appliance housings; (F) deficiencies in: (i) combustion and dilution air; (ii) gas shut-off valves; (iii) access to a gas shutoff valves that prohibit full operation; (iv) gas appliance connector materials; and (v) vent pipe, draft hood, draft, proximity to combustibles, and vent termination point and clearances. HYDRO-MASSAGE THERAPY EQUIPMENT 22 TAC 535.231(c) (1) The inspector shall report as Deficient: (A) inoperative units; (B) the presence of active leaks; (C) deficiencies in components and performance; (D) missing and damaged components; (E) the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish; and (F) the absence or failure of operation of ground-fault circuit interrupter protection devices; and (2) The inspector is not required to determine the adequacy of self-draining features of circulation systems.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
5.1.1 - A. Plumbing Supply, Distribution Systems, and Fixtures

Bathtub caulk
Both bathroome in 7485 and 7483

  • Bathtub caulking needs improvement. FYI: Cleaning products that contain bleach can cause deterioration of caulking.
Handyman/DIY
$
Credit
Comment
5.1.2 - A. Plumbing Supply, Distribution Systems, and Fixtures

Seal tub spout & controls
All bathrooms in both condos

  • Tub spout and tub/shower controls should be sealed to avoid water intrusion in the wall.  FYI: Cleaning products that contain bleach can cause deterioration of caulking.
Handyman/DIY
$
Credit
Comment
5.1.3 - A. Plumbing Supply, Distribution Systems, and Fixtures

Tub stopper damaged
7485 and 7483

  • The tub stopper and or tube drain assembly is damaged and should be replaced.
Handyman
$
Credit
Comment
5.1.4 - A. Plumbing Supply, Distribution Systems, and Fixtures

Surface damage
7485 master bath & hallbath and 7483 master bath

  • Bathtub has some surface damage and should be repaired as necessary to prevent further damage/rusting.

Qualified Professional
$
Credit
Comment
5.1.5 - A. Plumbing Supply, Distribution Systems, and Fixtures

Soap holder damage/missing
7483 master bath

  • The bathtub enclosure soap dish holder is loose or missing. Some repairs to the tile enclosure may be needed to prevent water from damaging the wallboard behind the tile.

Tile Contractor
$
Credit
Comment
5.1.6 - A. Plumbing Supply, Distribution Systems, and Fixtures

Lose damaged shower tile
7483 hall bath & 7483 master bath

  • The tile shower enclosure requires repair.  Any loose or damaged tile, grout and caulking should be repaired or replaced as necessary.  Any damage to the wall behind the tile should also be repaired (if necessary).

Qualified Professional
$
Credit
Comment
5.1.7 - A. Plumbing Supply, Distribution Systems, and Fixtures

Improve grout / Caulking
7585 masterbath & hallbath & both bathrooms 7483

Cracked, deteriorated and/or missing shower stall grout and/or caulking should be repaired or replaced as necessary.  These conditions if left unchecked or un-corrected could result in water intrusion into the wall cavity.   FYI: Cleaning products that contain bleach can cause deterioration of caulking.


Tile Contractor
$
Credit
Comment
5.1.8 - A. Plumbing Supply, Distribution Systems, and Fixtures

Surface damage sink
7485 master bath & hallbath

  • The sink has some surface damage and should be repaired or replaced as necessary or as desired.


Qualified Professional
$
Credit
Comment
5.1.9 - A. Plumbing Supply, Distribution Systems, and Fixtures

Seal C-Top - BSplash
7485 & 7483 kitchen and bathrooms

  • The countertop needs to be resealed to the backsplash.  This usually needs to be done every year or every 6 months.
Handyman/DIY
$
Credit
Comment
5.1.10 - A. Plumbing Supply, Distribution Systems, and Fixtures

Prior leak evidence
7485 & 7483

  • Signs of a previous leak were observed under the kitchen and bathroom sinks. No leaks were found at the time of inspection but the cabinets should be repaired as necessary. 
Handyman/DIY
$
Credit
Comment
5.1.11 - A. Plumbing Supply, Distribution Systems, and Fixtures

Flapper Not functioning properly
7485 master bath

  • The commode flapper assembly should be adjusted or replaced so that the commode flushes properly without having to Hold the handle down.

Plumbing Contractor
$
Credit
Comment
5.1.12 - A. Plumbing Supply, Distribution Systems, and Fixtures

Spigots not hosebibs

• The outside faucets were spigots and not hosebibs. Extra freeze protection is needed during winter months. 

Qualified Professional
$
Credit
Comment
5.1.13 - A. Plumbing Supply, Distribution Systems, and Fixtures

No sink stopper
Both bathrooms in 7483 & 7485

There was no sink stopper at the time of inspection. 

Plumbing Contractor
$
Credit
Comment
5.1.14 - A. Plumbing Supply, Distribution Systems, and Fixtures

Cover missing or damaged

The cover was missing from the customer shutoff 

Qualified Professional
$
Credit
Comment
5.1.15 - A. Plumbing Supply, Distribution Systems, and Fixtures

Damaged meter box

• The meter box is damaged and should be replaced. 

Plumbing Contractor
$
Credit
Comment
5.1.16 - A. Plumbing Supply, Distribution Systems, and Fixtures

Customer valve box dirty

The customer valve box was dirty and a handle was not visible. 

Qualified Professional
$
Credit
Comment
5.1.17 - A. Plumbing Supply, Distribution Systems, and Fixtures

Shower diverter stuck
hallway bath 7485

The tub/shower diverted was stuck and should be replaced.

Plumbing Contractor
$
Credit
Comment
5.2.1 - B. Drains, Wastes, & Vents

Slow drain = Tub
7485 master bath & hallbath

The bathtub was observed to drain slowly, suggesting that an obstruction may exist.

Plumbing Contractor
$
Credit
Comment
5.3.1 - C. Water Heating Equipment

UNable to Find

It is recommended that the water heaters be located and inspected. i checked every accessible room and closet and was not able to find them.

Qualified Professional

6 - V. Appliances

IN NI NP D
6.1 A. Dishwashers X X
6.2 B. Food Waste Disposers X X
6.3 C. Range Hood and Exhaust Systems X X
6.4 D. Ranges, Cooktops, and Ovens X X
6.5 E. Microwave Ovens X
6.6 F. Mechanical Exhaust Vents and Bathroom Heaters X X
6.7 G. Garage Door Operators X
6.8 H. Dryer Exhaust Systems X X
A. Dishwashers: Comments
A. Dishwashers: Brand
Amana
C. Range Hood and Exhaust Systems: Comments
C. Range Hood and Exhaust Systems: Exhaust Hood Type
Re-circulate
D. Ranges, Cooktops, and Ovens: Comments
D. Ranges, Cooktops, and Ovens: Range, Cook Top, Oven
GE, Hotpoint
E. Microwave Ovens: Comments
E. Microwave Ovens: Brand
NA
F. Mechanical Exhaust Vents and Bathroom Heaters: Comments
A. Dishwashers: Dishwasher ok
7483

Picture of the dishwasher for reference. The dishwasher appeared to be working properly at the time of inspection. 

B. Food Waste Disposers: Comments

The disposal was tested and appeared to be working properly at the time of this inspection. 

B. Food Waste Disposers: Disposal OK
7483

The disposal was tested and appeared to be working properly at the time of this inspection. 

C. Range Hood and Exhaust Systems: Non-Vented OK
7483

The vent installed at the time of in ape toon was a recirculating type (Non Vented) It appeared to be working ok at the time of inspection

D. Ranges, Cooktops, and Ovens: Cooktop OK

The cooktop burners appeared to be performing properly at the time of this inspection. 

D. Ranges, Cooktops, and Ovens: Oven temperatures

The oven or ovens were tested at 350 degrees. 

D. Ranges, Cooktops, and Ovens: Range OK

The range was tested and appeared to be working properly at the time of inspection. 

G. Garage Door Operators: Comments

*The balance and operation of the garage door were tested and appeared to perform properly at the time of this inspection. 

*The garage door openers photo eye sensors were tested and appeared to be working properly at the time of this inspection. 

* The auto reverse safety feature was tested with hand pressure and found to be working properly at the time of this inspection. 

H. Dryer Exhaust Systems: Comments
  • Any deficiencies listed below in this section should be further evaluated corrected as necessary by a contractor qualified to install, service & clean dryer vents.

H. Dryer Exhaust Systems: Dryer in place Not Inspected
  • The clothes dryer was in place on the day of inspection and the inside of the duct could not be seen. It is recommended that the condition of the duct be checked prior to connecting the clothes dryer to it. If it is dirty it should be cleaned for reasons of fire safety. Dryer vents should be cleaned regularly as part of normal home maintenance.

A. Dishwashers: Normal

The dishwasher is operated in the NORMAL mode.

C. Range Hood and Exhaust Systems: performance

Vents are operated with the switch.  Actual performance level is not evaluated.

G. Garage Door Operators: Close pressure

The close pressure sensor was not tested due to the high probability of damage occurring during this test process.  

GENERAL PROVISIONS 22 TAC 535.232(a) The inspector is not required to: (1) operate or determine the condition of other auxiliary components of inspected items; (2) test for microwave oven radiation leaks; (3) inspect self-cleaning functions; (4) disassemble appliances; (5) determine the adequacy of venting systems; or (6) determine proper routing and lengths of duct systems. DISHWASHERS 22 TAC 535.232(b) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) rusted, missing or damaged components; (4) the presence of active water leaks; and (5) the absence of backflow prevention. FOOD WASTE DISPOSERS 22 TAC 535.232(c) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) missing or damaged components; and (4) the presence of active water leaks. RANGE HOODS AND EXHAUST SYSTEMS 22 TAC 535.232(d) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) missing or damaged components; (4) ducts that do not terminate outside the building, if the unit is not of a re-circulating type or configuration; and (5) improper duct material.  ELECTRIC OR GAS RANGES, COOKTOPS, AND OVENS 22 TAC 535.232(e) The inspector shall report as Deficient: (1) inoperative units; (2) missing or damaged components; (3) combustible material within thirty inches above the cook top burners; (4) absence of an anti-tip device, if applicable; (5) gas leaks; (6) the absence of a gas shutoff valve within six feet of the appliance; (7) the absence of a gas appliance connector or one that exceeds six feet in length; (8) gas appliance connectors that are concealed within or extended through walls, floors, partitions, ceilings or appliance housings; (9) deficiencies in: (A) thermostat accuracy (within 25 degrees at a setting of 350 F); (B) mounting and performance; (C) gas shut-off valves; (D) access to a gas shutoff valves that prohibits full operation; and (E) gas appliance connector materials. MICROWAVE OVENS 22 TAC 535.232(f) The inspector shall inspect built-in units and report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; and (3) missing or damaged components. MECHANICAL EXHAUST SYSTEMS AND BATHROOM HEATERS 22 TAC 535.232(g) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) missing or damaged components; (4) ducts that do not terminate outside the building; and (5) a gas heater that is not vented to the exterior of the building unless the unit is listed as an unvented type.  GARAGE DOOR OPERATORS 22 TAC 535.232(h) The inspector shall report as Deficient: (1) inoperative units; (2) deficiencies in performance or mounting; (3) missing or damaged components; (4) installed photoelectric sensors located more than six inches above the garage floor; and (5) door locks or side ropes that have not been removed or disabled.  DRYER EXHAUST SYSTEMS 22 TAC 535.232(i) The inspector shall report as Deficient: (1) missing or damaged components; (2) the absence of a dryer exhaust system when provisions are present for a dryer; (3) ducts that do not terminate to the outside of the building; (4) screened terminations; and (5) ducts that are not made of metal with a smooth interior finish.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiency
$
Credit
Comment
6.1.1 - A. Dishwashers

Not secure
7483 & 7485

The dishwasher is loose at the cabinetry and should be better secured.

Handyman/DIY
$
Credit
Comment
6.1.2 - A. Dishwashers

Leaks on floor
7485

The dishwasher leaked water onto the floor when operated. This condition should be further evaluated and corrected as necessary.

Appliance Repair
$
Credit
Comment
6.2.1 - B. Food Waste Disposers

Wire not secure
7485 & 7483

The electrical wiring to the food waste disposer is not properly secured to the disposer housing.

Appliance Repair
$
Credit
Comment
6.2.2 - B. Food Waste Disposers

Debris inside
7485

The disposal was noisy with debris inside and should be cleaned.

Qualified Professional
$
Credit
Comment
6.3.1 - C. Range Hood and Exhaust Systems

X filter
7485

The range exhaust vent filter is missing.

DIY
$
Credit
Comment
6.3.2 - C. Range Hood and Exhaust Systems

Light inop
7485

The light at the range hood is inoperative.

Appliance Repair
$
Credit
Comment
6.4.1 - D. Ranges, Cooktops, and Ovens

No Anti-Tip
7485 & 7483

The range can be easily tipped over and should be equipped with an anti-tip device, for safety.  This may be an as-built condition but Per TREC standards of practice we are required to report this condition as a deficiency.

Handyman/DIY
$
Credit
Comment
6.4.2 - D. Ranges, Cooktops, and Ovens

Oven light inop

The oven light did not work and should be corrected.

Qualified Professional
$
Credit
Comment
6.6.1 - F. Mechanical Exhaust Vents and Bathroom Heaters

Inoperative Vent Fan
7485 hallbath

The mechanical exhaust vent fan appears to be inoperative.

Handyman
$
Credit
Comment
6.6.2 - F. Mechanical Exhaust Vents and Bathroom Heaters

Light inop
7485 masterbath & 7483 hallbath

The vent fan light was inoperative. 

Qualified Professional
$
Credit
Comment
6.8.1 - H. Dryer Exhaust Systems

Wrong type of termination

  • This type of roof level dryer vent termination is not approved for use with dryer vents. There should be a flapper that keeps birds or rodents from entering the ductwork. It is also important that no screens be installed. Screens can trap lint and create a fire hazard. It is recommended that the dryer vent termination be replaced with one approved for use on dryer vent ducts.

Qualified Professional