Viewing:

205 Stillwater Cresent
Waterdown , Ontario L0R 2H8
05/09/2018 4:30 pm

35
Recommendation
4
Safety hazard

1 - Inspection Details

In Attendance
Home Owner
Occupancy
Furnished, Occupied
Style
Multi-level
Temperature (approximate)
26 Celsius (C)
Type of Building
Detached, Single Family
Weather Conditions
Clear

2 - Roof

IN NI NP O
2.1 Coverings X X
2.2 Roof Drainage Systems X X
2.3 Flashings X X
2.4 Skylights, Chimneys & Other Roof Penetrations X X
Inspection Method
Ladder, Roof, Drone
Roof Type/Style
Gambrel, Hip
Coverings: Material
Asphalt
Roof Drainage Systems: Gutter Material
Aluminum
Flashings: Material
Aluminum

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
2.1.1 - Coverings

Damaged (General)

Roof coverings showed moderate damage. Recommend a qualified roofing professional evaluate and repair. 

Builder
CAD$
Credit
Comment
2.1.2 - Coverings

Shingle Cracked/Broken

Roof had cracked/broken tiles. Recommend a qualified roof contractor repair or replace to prevent moisture intrusion and/or mold. 

Builder
CAD$
Credit
Comment
2.1.3 - Coverings

Shingles Missing

Observed areas that appeared to be missing sufficient coverings. Recommend qualified roofing contractor evaluate & repair. 

Builder
CAD$
Credit
Comment
2.2.1 - Roof Drainage Systems

Downspouts Drain Near House

One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor adjust downspout extensions to drain at least 4 to 6 feet from the foundation. 

Here is a helpful DIY link and video on draining water flow away from your house. 

DIY
CAD$
Credit
Comment
2.2.2 - Roof Drainage Systems

Downspouts Missing

Home was missing downspouts in one or more areas. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor install downspout extensions that drain at least 6 feet from the foundation. 

Builder
CAD$
Credit
Comment
2.2.3 - Roof Drainage Systems

Gutters Missing

There are no gutters present on the structure.  Gutters are recommended because they collect rain water from the roof and direct it away form the building.

Builder
CAD$
Credit
Comment
2.3.1 - Flashings

Loose/Separated

Flashings observed to be loose or separated, which can lead to water intrusion and/or mold. Recommend a qualified roofing contractor repair. 

Builder
CAD$
Credit
Comment
2.4.1 - Skylights, Chimneys & Other Roof Penetrations

Roof Penetration flashings

More that one or more roof vent flashings poorly or improperly installed during roof installation.  It is a vital element of the roofing system. It keeps your roof waterproof and airtight, sealing the outer envelope that protects the interior of your home from weather and other elements. Recommend a qualified roofing contractor to repair or replace.

Builder

3 - Exterior

IN NI NP O
3.1 Foundation X X
3.2 Siding, Flashing & Trim X X
3.3 Walkways, Patios & Driveways X X
3.4 Decks, Balconies, Porches & Steps X X
3.5 Eaves, Soffits & Fascia
3.6 Vegetation, Grading, Drainage & Retaining Walls X X
3.7 Lighting X X
Inspection Method
Attic Access, Visual
Foundation: Material
Concrete
Siding, Flashing & Trim: Siding Material
Brick, Engineered Wood, Masonry, Wood
Siding, Flashing & Trim: Siding Style
Panels
Walkways, Patios & Driveways: Driveway Material
Asphalt
Decks, Balconies, Porches & Steps: Appurtenance
Balcony, Deck, Deck with Steps
Decks, Balconies, Porches & Steps: Material
Wood
Siding, Flashing & Trim: Windows
Basement

Basement slider window well and drainage systems missing at the time of the inspection. Recommend well and drainage to be installed immeadialty to prevent water and moisture penetration to the basement foundation.

Helpful link on basement window drainage

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
3.1.1 - Foundation

Improper Construction Practices

Improper or sub-standard construction practices were noted at the foundation wall meeting waterproofing. Recommend a quilified contractor to evaluate and advise on how to bring the construction up to standards. 

Builder
CAD$
Credit
Comment
3.2.1 - Siding, Flashing & Trim

Evidence of Water Intrusion

Exterior cladding/sidings showed signs of water intrusion. This could lead to further deterioration and/or mold or moisture damage. Flashing & trim pieces were improperly installed, which could result in moisture intrusion and damaging leaks. Recommend a qualified siding contractor evaluate and repairRecommend a qualified contractor evaluate and repair or replace to prevent further damage to the home.

Builder
CAD$
Credit
Comment
3.2.2 - Siding, Flashing & Trim

Warping/Buckling

Vinyl siding was warping or buckling in areas. This is often as a result of nailing siding boards to tight to the home, preventing expansion/contraction. Recommend a qualified siding contractor evaluate and repair.

Builder
CAD$
Credit
Comment
3.3.1 - Walkways, Patios & Driveways

Driveway Draining Towards Home

The driveway has a negative slope and drains towards the structure. Recommend a driveway contractor evaluate and repair.

Builder
CAD$
Credit
Comment
3.3.2 - Walkways, Patios & Driveways

Driveway Trip Hazard

Ashphalt driveway showing sign of trip hazards located one or more areas. Client waiting for final ashphalt installation.

Builder
CAD$
Credit
Comment
3.4.1 - Decks, Balconies, Porches & Steps

Railing Unsafe

There is an unsafe opening in the railing. The spacing on the rail should not exceed 4". An opening greater than 4" is a serious safety hazard especially for children. Recommend repair or replacement to avoid serious injury.

Builder
CAD$
Credit
Comment
3.4.2 - Decks, Balconies, Porches & Steps

Stairs -Missing

One or more sections of the exterior stairs are missing. Recommend qualified contractor evaluate & repair.

Builder
CAD$
Credit
Comment
3.5.1 - Eaves, Soffits & Fascia

Soffit Venting- Damaged

One of soffit area is damaged. Recommend qualified roofer evaluate & repair.

Builder
CAD$
Credit
Comment
3.6.1 - Vegetation, Grading, Drainage & Retaining Walls

Negative Grading

Grading is sloping towards the home in some areas. This could lead to water intrusion and foundation issues. Recommend qualified landscaper or foundation contractor regrade so water flows away from home.

Here is a helpful article discussing negative grading. 

Builder
CAD$
Credit
Comment
3.7.1 - Lighting

Weatherproofing

Improper construction practices, exterior light must be weather tight to prevent moisture damage. Recommend qualified professional to sealant/caulk areas where deficient.

Builder

4 - Basement, Crawlspace & Structure

IN NI NP O
4.1 Basements & Crawlspaces X
4.2 Floor Structure X X
4.3 Sump Pump X X
Inspection Method
Visual
Floor Structure: Material
Concrete
Floor Structure: Basement/Crawlspace Floor
Concrete
Sump Pump: Location
Basement

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
4.2.1 - Floor Structure

Concrete Slab Shifting/Cracking

Concrete slab was found to be cracking at the floor around backwater valve and storm drain access. This can be caused by moisture intrusion and/or soil movement. Recommend a concrete contactor evaluate and repair to preserve integrity of the home.

Builder
CAD$
Credit
Comment
4.2.2 - Floor Structure

Evidence of Water Intrusion

There were signs of water intrusion in the underlying floor structure. Recommend identifying source of moisture and repairing. 

Builder
CAD$
Credit
Comment
4.3.1 - Sump Pump

Improper Installation

Sump pump had sub-standard installation. Recommend a qualified plumber evaluate and properly install.

Builder

5 - Electrical

IN NI NP O
5.1 Service Entrance Conductors X X
5.2 Main & Subpanels, Service & Grounding, Main Overcurrent Device X
5.3 Branch Wiring Circuits, Breakers & Fuses
Service Entrance Conductors: Electrical Service Conductors
Below Ground
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main Panel Location
Basement
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Capacity
200 AMP
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Manufacturer
Eaton
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Type
Circuit Breaker
Branch Wiring Circuits, Breakers & Fuses: Branch Wire 15 and 20 AMP
Copper
Branch Wiring Circuits, Breakers & Fuses: Wiring Method
Conduit, Romex

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
5.1.1 - Service Entrance Conductors

Water Intrusion

There is possible water intrusion and the meter / service entrance. Moisture can deteriorate the electrical equipment. Recommend that a licensed electrician repair / replace as needed.

Builder

6 - Kitchen

IN NI NP O
6.1 Kitchen Sink X X

10.1 The inspector shall inspect: F. installed ovens, ranges, surface cooking appliances, microwave ovens, dishwashing machines, and food waste grinders by using normal operating controls to activate the primary function. 10.2 The inspector is NOT required to inspect: G. installed and free-standing kitchen and laundry appliances not listed in Section 10.1.F. H. appliance thermostats including their calibration, adequacy of heating elements, self cleaning oven cycles, indicator lights, door seals, timers, clocks, timed features, and other specialized features of the appliance. I. operate, or con rm the operation of every control and feature of an inspected appliance.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
6.1.1 - Kitchen Sink

Improper Installation

Improper installation of the drian and waste systems for kitchen sink. Poor construction practices, missing venting at island sink, Improper trap configurantion as well. 

Plumbing trap is a device which has a shape that uses a bending path to capture water to prevent sewer gases from entering buildings, while allowing waste to pass through also needs to have a proper clean-out installed. Recommend professional licence plumber to repair or replace and bring up to proper standards.


Builder

7 - Master Bedroom

IN NI NP O
7.1 General X X
7.2 Windows X X
7.3 Walls X
7.4 Ceilings X
7.5 Lighting Fixtures, Switches & Receptacles X
7.6 GFCI & AFCI X
7.7 Smoke Detectors X
7.8 Carbon Monoxide Detectors X
Windows: Window Type
Casement, Thermal
Windows: Window Manufacturer
Unknown
Walls: Wall Material
Drywall
Ceilings: Ceiling Material
Gypsum Board
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
7.2.1 - Windows

Improper Installation

Windows appear to not be operating properly due to substandard installation. Signs of water and moisture penetrations and also losing energy (poor caulking methods) Recommend window specialist evaluate.


Helpful link

Builder

8 - Bedroom 2

IN NI NP O
8.1 General X X
8.2 Windows X X
8.3 Walls X
8.4 Ceilings X
8.5 Lighting Fixtures, Switches & Receptacles X
8.6 GFCI & AFCI X
8.7 Smoke Detectors X
8.8 Carbon Monoxide Detectors X
Windows: Window Type
Casement, Thermal
Windows: Window Manufacturer
Unknown
Walls: Wall Material
Drywall
Ceilings: Ceiling Material
Gypsum Board
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
8.2.1 - Windows

Improper Installation

Windows appear to not be operating properly due to substandard installation. Signs of water and moisture penetrations and also losing energy (poor caulking methods) Recommend window specialist evaluate.


Helpful link on good window construction practices

Window Repair and Installation Contractor

9 - Upstairs Loft

IN NI NP O
9.1 General X
9.2 Windows X
9.3 Walls X
9.4 Ceilings X
9.5 Lighting Fixtures, Switches & Receptacles X
9.6 GFCI & AFCI X
9.7 Smoke Detectors X
9.8 Carbon Monoxide Detectors X
Windows: Window Type
Casement, Thermal
Walls: Wall Material
Drywall
Ceilings: Ceiling Material
Gypsum Board
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
9.2.1 - Windows

Improper Installation

Windows appear to not be operating properly due to substandard installation. Recommend window specialist evaluate.
Window Repair and Installation Contractor

10 - Bathroom 1

IN NI NP O
10.1 Toilet X
10.2 GFCI & AFCI X
10.3 Water Supply, Distribution Systems & Fixtures X
10.4 Lighting Fixtures, Switches & Receptacles
Water Supply, Distribution Systems & Fixtures: Distribution Material
Pex
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Hose, Pex
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations

11 - Bathroom 2

IN NI NP O
11.1 General
11.2 Water Supply, Distribution Systems & Fixtures X
11.3 Lighting Fixtures, Switches & Receptacles X
11.4 GFCI & AFCI X
11.5 Shower X
11.6 Toilet X
Water Supply, Distribution Systems & Fixtures: Distribution Material
Pex
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Hose, Pex
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations

12 - Bathroom 3

IN NI NP O
12.1 General X
12.2 Water Supply, Distribution Systems & Fixtures X
12.3 Lighting Fixtures, Switches & Receptacles X
12.4 GFCI & AFCI
12.5 Shower X X
12.6 Toilet X
Water Supply, Distribution Systems & Fixtures: Distribution Material
Pex
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Hose, Pex
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
12.5.1 - Shower

Shower Glass & Door

Master shower showing signs of water and moisture near the glass and door. Sealing method appears to have been installed substandard.

13 - Front Office

IN NI NP O
13.1 Windows X X
13.2 Walls X X
13.3 Ceilings X X
13.4 Lighting Fixtures, Switches & Receptacles X
13.5 GFCI & AFCI X
Windows: Window Type
Casement, Thermal
Windows: Window Manufacturer
Unknown
Walls: Wall Material
Drywall
Ceilings: Ceiling Material
Gypsum Board
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
13.1.1 - Windows

Damaged

One or more windows appears to have general damage, but are operational. Recommend a window professional clean, lubricate & adjust as necessary.

Builder
CAD$
Credit
Comment
13.1.2 - Windows

Improper Installation

Windows appear to not be operating properly due to substandard installation. Recommend window specialist evaluate. Showing signs of moisture and water damage at sills interior an exterior.

Window Repair and Installation Contractor
CAD$
Credit
Comment
13.2.1 - Walls

Poor Patching

Sub-standard drywall patching observed at time of inspection. Recommend re-patching. 

Builder
CAD$
Credit
Comment
13.3.1 - Ceilings

Stain(s) on Ceiling

There is a stain on ceiling/wall that requires repair and paint.  Source of staining should be determined.

Builder

14 - Laundry Room

IN NI NP O
14.1 Main Water Shut-off Device X
14.2 Drain, Waste, & Vent Systems X X
14.3 Exhaust Systems X X
14.4 Hot Water Systems, Controls, Flues & Vents X X
14.5 Fuel Storage & Distribution Systems X X
Filters
None
Water Source
Public
Dryer Power Source
220 Electric
Dryer Vent
Metal (Flex)
Main Water Shut-off Device: Location
Basement
Drain, Waste, & Vent Systems: Drain Size
1 1/2", 2"
Drain, Waste, & Vent Systems: Material
ABS
Exhaust Systems: Exhaust Fans
Fan Only
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Gas, Tankless
Hot Water Systems, Controls, Flues & Vents: Location
Basement
Fuel Storage & Distribution Systems: Main Gas Shut-off Location
Gas Meter
Hot Water Systems, Controls, Flues & Vents: Manufacturer
Rinnai, Reliance

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
14.2.1 - Drain, Waste, & Vent Systems

Emergency Drain/Curb Membrane

If the washing machine or its hoses leak onto the floor, the leak can spread onto the hardwood in nearby rooms on the same level or drip down onto the basement. Leaks in your laundry room can lead to major repairs in other areas of your home. You can waterproof your laundry room floor to prevent problems in this area.

 


 


15 - Utility Room

IN NI NP O
15.1 Cooling Equipment X X
15.2 Heating Equipment X
15.3 Distribution System X X
Cooling Equipment: Brand
Goodman
Cooling Equipment: Energy Source/Type
Central Air Conditioner
Cooling Equipment: Location
Exterior North
Heating Equipment: Brand
Goodman
Heating Equipment: Energy Source
Gas
Heating Equipment: Heat Type
Forced Air
Distribution System: Ductwork
Non-insulated
Distribution System: Configuration
Central
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations

16 - Misc. Interior

IN NI NP O
16.1 Distribution Systems X X
16.2 Vents, Flues & Chimneys X
16.3 Smoke Detectors X
16.4 Steps, Stairways & Railings X
16.5 Countertops & Cabinets X X
16.6 Gas/LP Firelogs & Fireplaces X X
Countertops & Cabinets: Countertop Material
Corian, Granite, Quartz
Countertops & Cabinets: Cabinetry
Laminate

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
16.2.1 - Vents, Flues & Chimneys

Vent Improperly Installed

Gas fire place exhaust vent was improperly installed. Showing signs of water penetration and mositure. Recommend a qualified HVAC contractor evaluate and repair.

Builder
CAD$
Credit
Comment
16.6.1 - Gas/LP Firelogs & Fireplaces

Gas Fireplace and Venting

Living room gas fireplace showing signs of water penetration entering at the exterior vent. Recommend contracting a qualified contractor to prevent further damage to the home.

Builder

17 - Attic

IN NI NP O
17.1 Attic Insulation X X
17.2 Ventilation X X
17.3 Roof Structure & Attic X X
Attic Insulation: R-value
50
Attic Insulation: Insulation Type
Blown
Ventilation: Ventilation Type
Passive, Soffit Vents
Roof Structure & Attic: Material
OSB, Wood
Roof Structure & Attic: Type
Hip, Shed

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
17.1.1 - Attic Insulation

Improper Installation

An unknown white pvc pipe venting into the attic was installed. Recommend a qualified contractor evaluate and correct. 

Builder
CAD$
Credit
Comment
17.2.1 - Ventilation

Unknown Venting

Unknown white PVC piping located venting into the attic areas. Recommend qualified professional to further investigate the situation.

Builder
CAD$
Credit
Comment
17.3.1 - Roof Structure & Attic

Thin/Soft Sheathing

Roof sheathing appears to be damaged in certain areas. This can installation error and can effect underlying wood panels & structure. Recommend further examination by a qualified roofer.

Builder

18 - Garage

IN NI NP O
18.1 Garage Door X X
18.2 Garage Door Opener X
18.3 Occupant Door (From garage to inside of home) X X
Garage Door: Material
Metal, Non-insulated, Vinyl
Garage Door: Type
Automatic
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
CAD$
Credit
Comment
18.1.1 - Garage Door

Auto Reverse Sensor Not Working

The auto reverse sensor was not responding at time of inspection. This is a safety hazard to children and pets. Recommend a qualified garage door contractor evaluate and repair/replace. 

Builder
CAD$
Credit
Comment
18.1.2 - Garage Door

Panel Damage

Garage door panel is damaged and may need repair/replacement. Recommend a qualified garage door contractor evaluate. 

Builder