Note, If the Temperature is under 65 degrees the AC unit/s are not able to be tested due to the possibility of damaging the unit/s.
Brandon E. Warren
Ray Gill
Note, If the Temperature is under 65 degrees the AC unit/s are not able to be tested due to the possibility of damaging the unit/s.
IN | NI | NP | D | ||
---|---|---|---|---|---|
2.1 | Coverings | X | X | ||
2.2 | Roof Drainage Systems | X | X | ||
2.3 | Flashings | X | X | ||
2.4 | Skylights, Chimneys & Other Roof Penetrations | X |
Unable to walk the entire roof and or certain areas of the roof due to the pitch. Multiple areas of the roof inspected from a ladder for safety reasons.
I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.
Observed one or more under-driven nails/fasteners. Recommend a qualified roofing contractor evaluate and repair.
One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor adjust downspout extensions to drain at least 6 feet from the foundation.
Here is a helpful DIY link and video on draining water flow away from your house.
These downspout connections are improperly sealed with a caulk like material.This material is already starting to break down due to weather/UV rays. Using a gutter calculator, the size of the roof, accompanied by the pitch; the two downspouts for the main area of the roof is barely enough to mange water drainage for the roofs square footage. Recommend a gutter contractor to evaluate and determine accurate number of downspouts, and properly seal, slope, and attach the gutters/downspouts.
Gutters were damaged. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor evaluate and repair.
The gutter(s) is loose and needs to be re-fastened to fascia and pitched properly.
The downspout(s) is loose and needs to be re-fastened to the exterior of the structure properly.
Flashings observed to be loose or separated, which can lead to water intrusion and/or mold. Recommend a qualified roofing contractor repair.
IN | NI | NP | D | ||
---|---|---|---|---|---|
3.1 | Siding, Flashing & Trim | X | X | ||
3.2 | Exterior Doors | X | X | ||
3.3 | Walkways, Patios & Driveways | X | X | ||
3.4 | Decks, Balconies, Porches & Steps | X | X | ||
3.5 | Eaves, Soffits & Fascia | X | |||
3.6 | Vegetation, Grading, Drainage & Retaining Walls | X | X |
I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.
Open hole/s are noted in the siding which can lead to moisture intrusion. Recommend filling the holes with the appropriate sealant.
Note - Other holes noted around the house that have already been caulked and painted. Monitor those areas to ensure caulk material is performing as intended, and preventing moisture intrusion.
Door is missing standard weatherstripping and or needs larger size. This can result in significant energy loss and moisture intrusion. Recommend installation of standard weatherstripping of the correct size.
Sidewalk/Walkway/Patio has improper slope/pitch towards the structure, and could possibly cause moisture intrusion. Monitor to ensure moisture intrusion is not present.
Note - Water Stains are noted on the concrete from improper drainage and sloping.
The ledger board is not properly attached to the building. This can cause the deck to pull away from the building and possibly collapse. Recommend that the deck and/or ledger board be properly attached by qualified contractor.
Note - The ledger board is not properly attached to the house because of excessive wood rot. The cause is improper flashing of the door sill above which has allowed water to penetrate behind the siding for years. This caused the excessive rot to the sole plate and possibly other structural members in this direct area.
The Deck railing appears to be loose. The railing needs to be refastened, and or replaced for safety.
Grading is sloping towards the home in some areas. This could lead to water intrusion and foundation issues. Recommend qualified landscaper or foundation contractor regrade so water flows away from home.
Here is a helpful article discussing negative grading.
IN | NI | NP | D | ||
---|---|---|---|---|---|
4.1 | Foundation | X | X | ||
4.2 | Basements & Crawlspaces | X | X | ||
4.3 | Floor Structure | X | |||
4.4 | Wall Structure | X | X | ||
4.5 | Ceiling Structure | X |
I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.
Severe cracking noted at the foundation. This is typically consistent with soil movement and could lead to serious damage to structural components, foundation and/or slabs. Recommend a Qualified Professional evaluate and provide a report on course of action and remedy.
Here is an informational article on foundation cracks.
Note - Parging was evident at most of the basement window corners. Cracks like these can lead to moisture intrusion in the basement, and continued separation from freezing. The crack shown below is also in the area where it appears a large tree was removed at some point, so this could have been the result of root damage.
Open Pipe/Wire Chase/s should be properly sealed to prevent moisture intrusion, and insects from enter the structure.
Evidence of structural damage was found in the wall structure. Recommend a qualified structural engineer evaluate and advise on how to repair.
Note - Excessive wood rot noticed at the back of the house under the siding. The cause is improper flashing of the door sill above which has allowed water to penetrate behind the siding for years. This caused the excessive rot to the sole plate and possibly other structural members in this direct area.
IN | NI | NP | D | ||
---|---|---|---|---|---|
5.1 | Equipment | X | X | ||
5.2 | Normal Operating Controls | X | |||
5.3 | Distribution Systems | X | X | ||
5.4 | Presence of Installed Heat Source in Each Room | X |
For your convenience
AFUE (Annual fuel utilization efficiency) is a metric used to measure furnace efficiency in converting fuel to energy. A higher AFUE rating means greater energy efficiency. 90% or higher meets the Department of Energy's Energy Star program standard.
Home is equipped with a Smart Thermostat which will help reduce energy costs. Due to the thermostat some testing operations may be limited on the part of the Inspector
I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.
The furnace filter is dirty and needs to be replaced every 6 months.
Heating element was inoperable at time of inspection. Recommend qualified HVAC professional evaluate & ensure functionality.
Note - Code Flashing - Pressure Switch Open Fault per schematic
Furnace should be cleaned and serviced annually. Recommend a qualified HVAC contractor clean, service and certify furnace.
Here is a resource on the importance of furnace maintenance.
Air supply duct was leaking air. Recommend a qualified HVAC Processional or vents & ducts contractor repair.
IN | NI | NP | D | ||
---|---|---|---|---|---|
6.1 | Cooling Equipment | X | |||
6.2 | Normal Operating Controls | X | |||
6.3 | Distribution System | X | X | ||
6.4 | Presence of Installed Cooling Source in Each Room | X |
Modern standards call for at least 13 SEER rating for new install.
Read more on energy efficient air conditioning at Energy.gov.
Home is equipped with a Smart Thermostat which will help reduce energy costs. Due to the thermostat some testing operations may be limited on the part of the Inspector
Due to the temperature being below 65 degrees Fahrenheit, we are not able to test the AC Unit/s. If they were to be tested below this temperature threshold damage to the unit/s is highly likely. Recommend the units be serviced & tested by a Certified HVAC Professional when temperature allows.
I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.
Air supply duct was leaking air. Recommend a qualified HVAC Processional or vents & ducts contractor repair.
IN | NI | NP | D | ||
---|---|---|---|---|---|
7.1 | Main Water Shut-off Device | X | |||
7.2 | Drain, Waste, & Vent Systems | X | |||
7.3 | Water Supply, Distribution Systems & Fixtures | X | X | ||
7.4 | Hot Water Systems, Controls, Flues & Vents | X | X | ||
7.5 | Fuel Storage & Distribution Systems | X | |||
7.6 | Sump Pump | X | X |
I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding.
I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.
Toilet appears to be loose, recommend readjusting and tightening. If the toilet appears to be an older fixture recommend replacing the wax ring.
The shower head appears to be loose inside the wall cavity at the connection. Recommend tightening, and or replacing to prevent a water leak inside the wall.
Temperature Pressure-Relief or TPR valves are safety devices installed on water heating appliances, such as boilers and domestic water supply heaters. TPR's are designed to automatically release water in the event that pressure or temperature in the water tank exceeds safe levels. TPR must discharge within six inches (6") of the floor.
Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding.
IN | NI | NP | D | ||
---|---|---|---|---|---|
8.1 | Service Entrance Conductors | X | |||
8.2 | Main & Subpanels, Service & Grounding, Main Overcurrent Device | X | X | ||
8.3 | Branch Wiring Circuits, Breakers & Fuses | X | |||
8.4 | Lighting Fixtures, Switches & Receptacles | X | X | ||
8.5 | GFCI & AFCI | X | X | ||
8.6 | Smoke Detectors | X | |||
8.7 | Carbon Monoxide Detectors | X |
The GFCI to reset the outside outlets is located here. Just for your information!
I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.
Circuit breaker was incorrectly wired / installed. This indicates that work was probably not performed by a licensed electrician and poses a safety hazard. Recommend that a licensed electrician check the entire panel and repair and replace as need.
Multiple 12 gauge lines on 15 amp breakers. Need to be 20 amp breakers for 12 gauge wire and 15 amp breakers for 14 gauge wire.
At the time of inspection, panel was missing labeling. Recommend a qualified electrician or person identify and map out locations.
Previous Service Terminated but still remains attached to the structure. Service is no longer energized therefor its no longer needed. Recommend it be removed from the house and that the holes be properly filled/covered.
Light fixtures are either not operable, missing parts, or not installed properly. Recommend the correct parts be installed, or the fixtures be repaired or replaced.
No GFCI protection present in all locations. Recommend licensed electrician upgrade by installing ground fault receptacles in all locations.
Here is a link to read about how GFCI receptacles keep you safe.
IN | NI | NP | D | ||
---|---|---|---|---|---|
9.1 | Vents, Flues & Chimneys | X | |||
9.2 | Components | X | |||
9.3 | Damper Doors | X | |||
9.4 | Cleanout Doors & Frames | X |
I. The inspector shall inspect:
readily accessible and visible portions of the fireplaces and chimneys;
lintels above the fireplace openings;
damper doors by opening and closing them, if readily accessible and manually operable; and
cleanout doors and frames.
II. The inspector shall describe:
the type of fireplace.
III. The inspector shall report as in need of correction:
evidence of joint separation, damage or deterioration of the hearth, hearth extension or chambers;
manually operated dampers that did not open and close;
the lack of a smoke detector in the same room as the fireplace;
the lack of a carbon-monoxide detector in the same room as the fireplace; and
cleanouts not made of metal, pre-cast cement, or other non-combustible material.
IV. The inspector is not required to:
inspect the flue or vent system.
inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels.
determine the need for a chimney sweep.
operate gas fireplace inserts.
light pilot flames.
determine the appropriateness of any installation.
inspect automatic fuel-fed devices.
inspect combustion and/or make-up air devices.
inspect heat-distribution assists, whether gravity-controlled or fan-assisted.
ignite or extinguish fires.
determine the adequacy of drafts or draft characteristics.
move fireplace inserts, stoves or firebox contents.
perform a smoke test.
dismantle or remove any component.
perform a National Fire Protection Association (NFPA)-style inspection.
perform a Phase I fireplace and chimney inspection.
IN | NI | NP | D | ||
---|---|---|---|---|---|
10.1 | Attic Insulation | X | |||
10.2 | Vapor Retarders (Crawlspace or Basement) | X | |||
10.3 | Ventilation | X | |||
10.4 | Exhaust Systems | X | X |
I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.
Ductwork is loose or disconnected. Recommend repair, and proper insulating to prevent moisture intrusion.
IN | NI | NP | D | ||
---|---|---|---|---|---|
11.1 | Doors | X | X | ||
11.2 | Windows | X | X | ||
11.3 | Floors | X | |||
11.4 | Walls | X | |||
11.5 | Ceilings | X | |||
11.6 | Steps, Stairways & Railings | X | |||
11.7 | Countertops & Cabinets | X |
I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.
Door appears to be damaged, recommend a handyman to handle the repair.
One or more windows appears to have general damage. Recommend a window professional repair or replace as necessary.
IN | NI | NP | D | ||
---|---|---|---|---|---|
12.1 | Dishwasher | X | X | ||
12.2 | Refrigerator | X | |||
12.3 | Range/Oven/Cooktop | X | |||
12.4 | Garbage Disposal | X | X | ||
12.5 | Built-in Microwave | X | |||
12.6 | Dryer | X | X | ||
12.7 | Washing Machine | X |
Temperature system check
Dishwasher did not sound like it was operating as intended. Recommend a certified appliance repair man come to evaluate, and or repair.
Garbage disposal was inoperable at the time of inspection. Recommend qualified handyman repair.
Dryer vent not Present. Recommend a qualified contractor install a dryer vent.