Agency Name
4
Maintenance item
19
Recommendation
4
Safety hazard

1 - Inspection Details

In Attendance
Nobody
Occupancy
Vacant
Style
Ranch
Temperature (approximate)
55 Fahrenheit (F)
Type of Building
Single Family
Weather Conditions
Dry

2 - Roof

IN NI NP D
2.1 Coverings X X
2.2 Patio covering X X
2.3 Flashings X X
2.4 Skylights, Chimneys & Other Roof Penetrations X
Inspection Method
Ladder, Roof, Not fully visible
Roof Type/Style
Gable, Flat
Roof leaks
None observed at the time of inspection
Condition
Appears serviceable
Coverings: Material
Concrete, Tile
Coverings: Condition
not fully visible
Patio covering: Material
Asphalt, Rolled Roofing
Patio covering: Condition
defects
Flashings: Material
Aluminum
Flashings: Condition
Exposed fasteners
Skylights, Chimneys & Other Roof Penetrations: Skylights
None
Skylights, Chimneys & Other Roof Penetrations: Vents and flues caps
Appears serviceable
Not fully visible due to design

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
2.1.1 - Coverings

Damaged (General)

Roof coverings showed evidence of common weathering and light aging. Recommend a qualified roofing professional evaluate and repair as needed.

Contractor Qualified Professional
Credit
Comment
2.1.2 - Coverings

Tiles Cracked/Broken

Roof had cracked/broken tiles. Recommend a qualified roof contractor repair or replace to prevent moisture intrusion and/or mold. 

Contractor Qualified Professional
Credit
Comment
2.1.3 - Coverings

Underlayment

Unable to inspect roofing underlayment materials due to roofing tile design and limited visibility. Recommend further evaluation by licensed contractor with repairs as needed.

Contractor Qualified Professional
Credit
Comment
2.1.4 - Coverings

Debris

Minor debris build-up observed on roof at time of inspection recommend removal of debris to allow proper drainage.

Tools Handyman/DIY
Credit
Comment
2.2.1 - Patio covering

Damaged (General)

Roof coverings showed moderate damage, including swollen materials Recommend a qualified roofing professional evaluate and repair to make sure roof is watertight and to prevent potential damage. 

Contractor Qualified Professional
Credit
Comment
2.2.2 - Patio covering

Splitting

The asphalt composition shingle roof had torn or split shingles which could lead to moisture intrusion. Recommend a qualified roofing contractor repair. 

Contractor Qualified Professional
Credit
Comment
2.3.1 - Flashings

Exposed Nails in flashing

Exposed Fasteners were observed at the East End of the house in flashing. The Fasteners were not sealed. Recommend professional upgrades  and or repairs to prevent moisture entry buy a license contractor.


Contractor Qualified Professional

3 - Exterior

IN NI NP D
3.1 Siding, Flashing & Trim X X
3.2 Exterior Doors X
3.3 Walkways, Patios & Driveways X
3.4 Decks, Balconies, Porches & Steps X
3.5 Eaves, Soffits & Fascia X X
3.6 Vegetation, Grading, Drainage & Retaining Walls X X
Inspection Method
Visual
Siding, Flashing & Trim: Siding Material
Fiber Cement, Stucco
Siding, Flashing & Trim: Siding Style
Channel
Siding, Flashing & Trim: Condition
defects
Siding, Flashing & Trim: Wall / trim flashings
Appear serviceable
Exterior Doors: Exterior Entry Door
Glass, Wood
Exterior Doors: Condition
Appears serviceable
Walkways, Patios & Driveways: Driveway Material
Concrete
Walkways, Patios & Driveways: Driveway Condition
Appears serviceable
Walkways, Patios & Driveways: Patio material
Concrete
Walkways, Patios & Driveways: Patio Condition
Appears serviceable
Walkways, Patios & Driveways: Patio type
Open design
Walkways, Patios & Driveways: Patio structure material
Wood columns, wood
Walkways, Patios & Driveways: Sidewalk material
Concrete
Walkways, Patios & Driveways: Sidewalks
Appears serviceable
Decks, Balconies, Porches & Steps: Appurtenance
Patio, Sidewalk
Decks, Balconies, Porches & Steps: Appurtenance Material
Concrete, Wood
Decks, Balconies, Porches & Steps: Condition
Appears serviceable
Vegetation, Grading, Drainage & Retaining Walls: Grading
Level sight, drainage of the site and slope of soil at Foundation appears serviceable

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
3.1.1 - Siding, Flashing & Trim

Cracking - Minor

Siding showed cracking in one or more places. This is a result of temperature changes, and typical as homes with stucco age. Recommend monitoring with repairs as needed or desired.

Credit
Comment
3.1.2 - Siding, Flashing & Trim

Chipping
West

Chipping of Stucco was noted in various spots possibly due to Mechanical damage in the exterior stucco walls at the time of the inspection. Location West Wall South of patio door. Recommend professional repairs including patching and painting to prevent moisture entry and to minimize potential damages. Recommend evaluation and Repairs by a qualified professional

Contractor Qualified Professional
Credit
Comment
3.5.1 - Eaves, Soffits & Fascia

Paint/Finish Failing
West

The paint or finish is failing. This can lead to deterioration and rot of the material. Recommend that the araes be further evaluated ,properly prepared and painted / finished buy a license contractor.

Credit
Comment
3.6.1 - Vegetation, Grading, Drainage & Retaining Walls

Tree Overhang

Trees observed overhanging the roof. This can cause damage to the roof and prevent proper drainage. Recommend a qualified tree service trim to allow for proper drainage. 

4 - Basement, Foundation, Crawlspace & Structure

IN NI NP D
4.1 Foundation X X
4.2 Floor Structure X
4.3 Wall Structure X
4.4 Ceiling Structure X
4.5 Roof Structure & Attic X
Inspection Method
Visual
Foundation: Material
Concrete, Slab on Grade
Foundation: Floor construction first level
Concrete
Foundation: Floor construction second level
N/A
Floor Structure: Material
Concrete, Slab
Floor Structure: Condition
Appears serviceable, Floor not fully visible due to carpet and floor coverings
Wall Structure: Wall structure type
Wood frame
Wall Structure: Condition
Appears serviceable, limited inspection
Ceiling Structure: Ceiling structure type
Truss framing
Ceiling Structure: Condition
Appears serviceable, limited inspection
Roof Structure & Attic: Material
Wood
Roof Structure & Attic: Type
Truss system
Roof Structure & Attic: Condition
Appears serviceable, limited inspection
Roof Structure & Attic: Observation method
Partially accessed - due to construction design
Floor Structure: Partially visible

Partially visible due to grading, carpet and floor coverings. 

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
4.1.1 - Foundation

Foundation Cracks - Minor

Minor cracking was noted at the foundation. This is common as concrete ages and shrinkage surface cracks are normal. Recommend monitoring for more serious shifting/displacement. 

Here is an informational article on foundation cracks. Recommended repairs including patching / sealing by a licensed contractor. Monitor and keep moisture away from area.

Credit
Comment
4.1.2 - Foundation

Spalling and deterioration

Spalling and deterioration was noted at multiple locations surrounding Foundation stem wall. Possibly from overspray, recommended repairs including patching ceiling and monitoring and keeping moisture away from these areas. Recommend evaluation and Repairs by license contractor.

Contractor Qualified Professional

5 - Heating

IN NI NP D
5.1 Equipment X
5.2 Normal Operating Controls X
5.3 Distribution Systems X X
5.4 Presence of Installed Heat Source in Each Room X
Air filter
Appears serviceable
Equipment: Brand
AIRE-FLOW
Equipment: Energy Source
Electric
Equipment: Heat Type
,
Heat pump split
Equipment: Approximate BTUs
36000 BTUs
Equipment: Condition
Appears serviceable
Normal Operating Controls: Thermostat
Hallway outside master bedroom
Appears serviceable
Distribution Systems: Ductwork
Insulated, Not fully visible
Distribution Systems: Condition
defective
Distribution Systems: Registers
Appears serviceable, Heat Source present in every room
Normal Operating Controls: Automatic safety controls
Appears serviceable

On gas units examples would be limit switches and thermal couplers Etc and on electric it would be overcurrent protection fuses or circuit breakers.

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
5.3.1 - Distribution Systems

Duct Damaged
Attic near entry

Observed damaged/crushed ducting near attic access in garage. Recommend a qualified HVAC contractor repair.

6 - Cooling

IN NI NP D
6.1 Cooling Equipment X X
6.2 Normal Operating Controls X
6.3 Distribution System X
6.4 Presence of Installed Cooling Source in Each Room X
Cooling Equipment: Brand
AIRE-FLOW
Cooling Equipment: Energy Source/Type
Electric, Heat pump split
Cooling Equipment: Approximate BTUs
36000 BTUs
Cooling Equipment: Condenser
West exterior
Recommend further evaluation
Cooling Equipment: Electric disconnect
Present
Cooling Equipment: Air handler
Attic
Appears serviceable
Distribution System: Registers
Cooling Source present in every room
Unable to run due to temperature

Unable to run due to temperature. Low temperatures may damage equipment. Recommend regular servicing before start of summer to ensure proper operation

I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
6.1.1 - Cooling Equipment

Insulation Missing or Damaged

Missing or damaged insulation on refrigerant line can cause energy loss and condensation.
Tools Handyman/DIY
Credit
Comment
6.3.1 - Distribution System

Duct Damaged
Attic near entry

Observed damaged/crushed ducting near attic access in garage. Recommend a qualified HVAC contractor repair.

7 - Plumbing

IN NI NP D
7.1 Main Water Shut-off Device X X
7.2 Drain, Waste, & Vent Systems X
7.3 Water Supply, Distribution Systems & Fixtures X
7.4 Hot Water Systems, Controls, Flues & Vents X
Filters
None
Water Source
Public
Main Water Shut-off Device: Location
East side of house
East
Main Water Shut-off Device: Main Line material
Copper
Main Water Shut-off Device: Main line size
1 in
Main Water Shut-off Device: Main Line PSI
95
Main Water Shut-off Device: Main valve
operational
Drain, Waste, & Vent Systems: Drain Size
Unknown
Drain, Waste, & Vent Systems: Material
ABS
Drain, Waste, & Vent Systems: Waste lines material
ABS
Drain, Waste, & Vent Systems: Waste lines
Appear serviceable
Drain, Waste, & Vent Systems: Functional drainage
Appears serviceable, no leaks observed, all Vents and traps not fully visible, observe lines visually appear to be properly supported
Water Supply, Distribution Systems & Fixtures: Distribution Material
Copper, Pex
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Copper
Water Supply, Distribution Systems & Fixtures: Condition
Appeared serviceable
Water Supply, Distribution Systems & Fixtures: Functional flow
Appear serviceable, Cross connections were not observed, observed lines appear to be properly supported, No leaks were observed
Water Supply, Distribution Systems & Fixtures: Pipe insulation appears to be properly
N/A
Hot Water Systems, Controls, Flues & Vents: Water heater capacity
40 gallons
Hot Water Systems, Controls, Flues & Vents: Location
Garage
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Electric
Hot Water Systems, Controls, Flues & Vents: Water heater
Appears serviceable
Hot Water Systems, Controls, Flues & Vents: Water shut-off valve
Installed (no test) appears serviceable, Recommend Electric disconnect, recommend drain pan
Hot Water Systems, Controls, Flues & Vents: Temperature pressure relief valve
Installed (no test) appears serviceable
Hot Water Systems, Controls, Flues & Vents: Vents and flues
N/A
Hot Water Systems, Controls, Flues & Vents: Fuel system
N/A
Hot Water Systems, Controls, Flues & Vents: Manufacturer
Bradford & White

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
7.1.1 - Main Water Shut-off Device

Main PSI above 80

Recommend installation of pressure regulator to keep water PSI below 80

Pipes Plumbing Contractor

8 - Electrical

IN NI NP D
8.1 Service Entrance Conductors X
8.2 Main & Subpanels, Service & Grounding, Main Overcurrent Device X
8.3 Branch Wiring Circuits, Breakers & Fuses X
8.4 Lighting Fixtures, Switches & Receptacles X
8.5 GFCI & AFCI X
8.6 Smoke Detectors X X
Service Entrance Conductors: Electrical Service Conductors
South
Below Ground, Aluminum, 240 volts
Service Entrance Conductors: Condition
Appears serviceable
Service Entrance Conductors: Service ground
Appears serviceable
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main Panel Location
South side of house
Left
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Capacity
200 AMP
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Manufacturer
Square D
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Overcurrent protection device type
Circuit Breaker
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Overcurrent protection devices
Appear serviceable
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Sub Panel Location
None
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main panel condition
Appears serviceable
Branch Wiring Circuits, Breakers & Fuses: Branch Wire
Copper, 120 volt, 240 volt
Branch Wiring Circuits, Breakers & Fuses: Wiring Method
Romex
Branch Wiring Circuits, Breakers & Fuses: Branch wiring
Appears serviceable
Branch Wiring Circuits, Breakers & Fuses: Wire compatibility
Wires sizes appear to be compatible with correct Breakers sizes
Branch Wiring Circuits, Breakers & Fuses: Solid aluminum Branch wiring
None
Lighting Fixtures, Switches & Receptacles: Light switches
Appears serviceable
Lighting Fixtures, Switches & Receptacles: Electrical outlets
Appear serviceable, Grounding and polarity of receptacles within 6 ft of Plumbing fixtures serviceable
Lighting Fixtures, Switches & Receptacles: Light fixtures
Appears serviceable
Lighting Fixtures, Switches & Receptacles: Ceiling fans
Appear serviceable
Lighting Fixtures, Switches & Receptacles: Attic electrical items
Appeared serviceable
GFCI & AFCI: GFCI(s) ( ground-fault circuit interceptors)
GFCI(s) respond to test
Smoke Detectors: Smoke detectors
suggested additional detectors in appropriate locations, Appears serviceable

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
8.6.1 - Smoke Detectors

Smoke detector locations

Suggest additional detectors inappropriate locations

Contractor Qualified Professional

9 - Attic, Insulation & Ventilation

IN NI NP D
9.1 Attic Insulation X
9.2 Ventilation X
9.3 Exhaust Systems X
9.4 Bathroom ventilation X
9.5 Kitchen ventilation X
9.6 Vapor retarder X
Dryer Power Source
240 volt
Dryer Vent
Metal (Flex), Appears serviceable
Flooring Insulation
Blown-in
Laundry ventilation
Appears serviceable
Attic Insulation: Insulation Type
Blown
Attic Insulation: Insulation condition
Appeared serviceable
Ventilation: Ventilation Type
Gable Vents, Soffit Vents
Ventilation: Condition
Appears serviceable
Exhaust Systems: Exhaust Fans
Fan Only
Bathroom ventilation: Ventilation
Fan
Bathroom ventilation: Condition
Appears serviceable
Kitchen ventilation: Ventilation
Vents outside
Kitchen ventilation: Condition
Appears serviceable
Vapor retarder: Type
N/A
Vapor retarder: Condition
Not required

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

10 - Doors, Windows & Interior

IN NI NP D
10.1 Doors X
10.2 Windows X
10.3 Floors X X
10.4 Walls X X
10.5 Ceilings X X
10.6 Countertops & Cabinets X
Doorbell
Operational
Front door weather stripping
Appears serviceable
Doors: Interior doors
Appears serviceable
Doors: Closet doors
Appears serviceable
Doors: Sliding glass patio doors
Appears serviceable
Windows: Window Manufacturer
Unknown
Windows: Window Type
Single-hung, Sliders, Dual pane
Windows: Windows condition
Appears serviceable
Windows: Screens
Appears serviceable
Floors: Floor Coverings
Carpet, Tile
Floors: Condition
Appears serviceable, tile grout lifting or missing
Walls: Wall Material
Drywall
Walls: Condition
Appears serviceable
Ceilings: Ceiling Material
Drywall
Ceilings: Condition
Appears serviceable
Countertops & Cabinets: Cabinetry
Laminate
Countertops & Cabinets: Countertop Material
Laminate
Countertops & Cabinets: Condition
Appears serviceable, light wear

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
10.3.1 - Floors

Tile grout

Tile grout was missing/ popping up in one or more locations. Recommend pulling out popped up pieces and refilling spots where grout was missing.

Credit
Comment
10.4.1 - Walls

Common imperfections

Common building imperfections and or defects were noted on the interior walls at the time of the inspection. Including common cracks, evidence of Prior patching / repairs and minor mechanical damages. Recommended monitoring with repairs as needed or desired

Contractor Qualified Professional
Credit
Comment
10.5.1 - Ceilings

Common imperfections

Common building imperfections and or defects were noted on the interior ceilings at the time of the inspection. Including common cracks, evidence of Prior patching / repairs and minor mechanical damages. Recommended monitoring with repairs as needed or desired

Contractor Qualified Professional

11 - Garage

IN NI NP D
11.1 Ceiling X X
11.2 Floor X X
11.3 Walls & Firewalls X X
11.4 Garage Door X X
11.5 Garage Door Opener X
11.6 Occupant Door (From garage to inside of home) X
Type
attached
Floor: Material
Concrete, Slab, Wood Beams
Walls & Firewalls: Wall Material
Drywall
Walls & Firewalls: Condition
Appears serviceable
Garage Door: Material
Aluminum
Garage Door: Type
Roll-Up
Garage Door Opener: Garage door opener
Appears serviceable
Garage Door Opener: Garage door safety reverse
Appears serviceable
Occupant Door (From garage to inside of home): Door to interior type
Solid
Occupant Door (From garage to inside of home): Condition
Appears serviceable
Occupant Door (From garage to inside of home): Self closing door
Operational
Floor: Not fully visible

Garage floor was not fully visible due to occupants belongings at time of inspection.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
11.1.1 - Ceiling

Common cracks

Common cracks minor patching a mechanical damages were found in the ceiling at the time of inspection. Recommend repairs and monitoring to ensure fire rating is maintained.

Putty knife Drywall Contractor
Credit
Comment
11.2.1 - Floor

Minor cracking

Common cracks we're found on the garage floor up to 1/8 of an inch. Recommend monitoring to make sure they are not getting bigger or becoming a tripping hazard.

Mag glass Monitor
Credit
Comment
11.3.1 - Walls & Firewalls

Damaged Drywall

Garage wall had damaged drywall. Recommend drywall contractor repair to ensure fire rating is maintained.

Putty knife Drywall Contractor
Credit
Comment
11.4.1 - Garage Door

Improper Installation

Garage door was improperly installed and appears un balanced when opening/closing. Recommend a qualified garage door contractor evaluate and repair. 

Garage Garage Door Contractor
Credit
Comment
11.4.2 - Garage Door

Panel Damage

Garage door panel is damaged and may need repair/replacement. Recommend a qualified garage door contractor evaluate. 

Garage Garage Door Contractor

12 - Bathrooms

IN NI NP D
12.1 Bathtub X
12.2 Shower X
12.3 Sink X
12.4 Toilet X
Bathtub: Condition
Appears serviceable
Bathtub: Functional flow
Appears serviceable
Bathtub: Functional drainage
Appears serviceable
Shower: Condition
Appears serviceable
Shower: Functional flow
Appears serviceable
Shower: Functional drainage
Appears serviceable
Sink: Condition
Appears serviceable
Sink: Functional flow
Appears serviceable
Sink: Functional drainage
Appears serviceable
Toilet: Condition
Appears serviceable
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies

13 - Kitchen

IN NI NP D
13.1 Dishwasher X X
13.2 Disposal X
13.3 Kitchen Electric X
13.4 Range/ cooktop X
13.5 Sink X
Dishwasher: Condition
worn
Disposal: Condition
Appeared serviceable
Kitchen Electric: GFCI(s) ( ground-fault circuit interceptors)
GFCI(s) respond to test
Range/ cooktop: Energy source
electric
Range/ cooktop: Condition
Appears serviceable
Range/ cooktop: Anti-tip
Present
Sink: Condition
Appears serviceable
Sink: Functional flow
Appears serviceable
Sink: Functional drainage
Appears serviceable
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • D = Deficiencies
Credit
Comment
13.1.1 - Dishwasher

Rust

Rust was noted at the time of inspection on upper and lower rack. Not sanitary recommend replacing racks or upgrading dishwasher as needed.

Contractor Qualified Professional