1 - Inspection Details

In Attendance
Client, Home Owner
Occupancy
Occupied
Style
Single-family 2 Story
Type of Building
Detached
Weather Conditions
Clear
Temperature (approximate)
80 Fahrenheit (F)

2 - Roof

IN NI NP O
2.1 Roof Covering X
2.2 Roof Sheathing X
2.3 Roof Framing/Structure X
2.4 Gutters & Downspouts X
2.5 Roof Flashings & Trim X
2.6 Chimneys, Skylights & Other Roof Penetrations X
Inspection Method
Aerial via drone, Visual Observation from Ground
Roof Type/Style
Gable/Hip
Gutters & Downspouts: Gutter Material
Aluminum
Roof Flashings & Trim: Material
Aluminum
Roof Covering: Material
Composite Shingle

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
2.1.1 - Roof Covering

Debris on Roof

Observed leaves, branches and other debris on the roof surface. Removal recommended. 

Tools Handyman/DIY
$
Credit
Comment
2.1.2 - Roof Covering

Damaged Shingles

Observed a few cracked, torn, or otherwise damaged shingles. Recommend replacing these shingles to prevent water entry.

Contractor Qualified Professional
$
Credit
Comment
2.1.3 - Roof Covering

Exposed Nail Heads

Observed several exposed nail heads on the roof surface. Recommend applying a waterproof sealant over each.

Contractor Qualified Professional
$
Credit
Comment
2.1.4 - Roof Covering

Shingles no Longer Secured

Observed a few locations where the shingles are beginning to pull away from the fasteners. Repair recommended.

Contractor Qualified Professional
$
Credit
Comment
2.1.5 - Roof Covering

Discoloration, Moss Growth

Discoloration (i.e., staining) and moss growth were observed over the majority of the roof's surface. The roof's age (24 yrs.) and the location of the home are the primary causes. Recommend trimming the branches of nearby trees so that the roof receives more sunlight and dries faster. Cleaning products and a low-pressure hose can be used to remove the moss in the short-term.

Contractor Qualified Professional
$
Credit
Comment
2.1.6 - Roof Covering

Missing Chimney Cap Flashing

A piece of aluminum flashing on one side of the chimney cap was missing. Repair recommended. 

Contractor Qualified Professional
$
Credit
Comment
2.1.7 - Roof Covering

Insufficient Overhang

Observed several locations where the shingles don't extend past the fascia board flashing. Ideally, there should be a drip edge flashing installed as well. Further evaluation/repair recommended.

Contractor Qualified Professional
$
Credit
Comment
2.4.1 - Gutters & Downspouts

Downspouts Drain Near House

It's recommended that all downspouts have extensions or splash blocks so that rainwater is discharged a minimum of six feet away from the home's foundation. 

Wrench DIY

3 - Foundation, Structure & Crawlspace

IN NI NP O
3.1 Foundation X
3.2 Crawlspace X
3.3 Floor Structure X
3.4 Wall Structure X
3.5 Ceiling Structure X
3.6 Insulation X
Inspection Method
Attic Access, Infrared, Visual
Foundation: Material
Slab on Grade
Floor Structure: Material
Concrete, Inaccessible
Floor Structure: Sub-floor
Inaccessible

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations

4 - Exterior

IN NI NP O
4.1 Walkways, Patios & Driveways X
4.2 Eaves, Soffits & Fascia X
4.3 Siding, Flashing & Trim X
4.4 Windows X
4.5 Doors X
4.6 Decks, Balconies, Porches & Steps X
4.7 Vegetation, Grading, Drainage & Retaining Walls X
4.8 Fencing X
4.9 Lighting X
Inspection Method
Infrared, Drone, Moisture Meter, Macro/Micro Visual
Siding, Flashing & Trim: Siding Material
Stucco
Windows: Window Type
Casement, Double-hung
Windows: Window Manufacturer
Unknown
Doors: Exterior Entry Door
Glass, Steel
Decks, Balconies, Porches & Steps: Appurtenance
Covered Porch, Deck with Steps, Patio
Decks, Balconies, Porches & Steps: Material
Concrete, Wood
Walkways, Patios & Driveways: Driveway Material
Concrete, Gravel, Pavers
Lighting: Unable to Test

One of the exterior light fixtures had no bulbs and could not be tested.

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
4.1.1 - Walkways, Patios & Driveways

Walkway Settlement
Back Left Corner (when facing front)

The sidewalk that leads to the back deck has experienced settlement due to inadequate backfill. Cracks in the concrete are visible and an uneven walking surface is present (trip hazard). Recommend adding a retaining wall to prevent further erosion underneath the sidewalk.

Contractor Qualified Professional
$
Credit
Comment
4.2.1 - Eaves, Soffits & Fascia

Damage - Minor

Observed a few holes in the aluminum soffit as well as some surface rust. Recommend filling holes and cleaning, painting the areas with rust.

Tools Handyman/DIY
$
Credit
Comment
4.3.1 - Siding, Flashing & Trim

Trim Damage

Observed some damage to the wooden trim above the living room windows. Recommend replacing the damaged section. In the future, you might consider replacing the wood trim with PVC.

Tools Handyman/DIY
$
Credit
Comment
4.3.2 - Siding, Flashing & Trim

Moisture Intrusion

There were a few locations that have evidence of elevated moisture levels (i.e., dark stains, moss growth). Infrared testing also indicated possible moisture accumulation behind the stucco. Stucco must be carefully monitored and treated to ensure it repels water, dries quickly and does not trap water behind its surface and onto the OSB sheathing. One common problem with stucco siding is wood rot around exterior windows. Recommend further evaluation and repair (if necessary).

Brick Masonry, Concrete, Brick & Stone
$
Credit
Comment
4.5.1 - Doors

Threshold, Frame Misalignment

One of the exterior door frames is out of alignment. Repair recommended.

Contractor Qualified Professional
$
Credit
Comment
4.5.2 - Doors

Damage

The exterior door in the living room is damaged along the bottom. Also, rust was observed on several exterior doors. Repair/replacement recommended.

Contractor Qualified Professional
$
Credit
Comment
4.5.3 - Doors

Flashing/Trim Damage

Observed minor damage to flashing or trim pieces on all exterior doors. Recommend replacing the damaged materials.

Tools Handyman/DIY
$
Credit
Comment
4.6.1 - Decks, Balconies, Porches & Steps

Unapproved Building Materials & Practices
Exterior - Rear

The back deck is supported by sections of timber that appear to be resting on the ground. It's unclear if/how the framing is secured and there is no lateral bracing. Recommend modification of the deck support system to stabilize the structure. 

Contractor Qualified Professional
$
Credit
Comment
4.6.2 - Decks, Balconies, Porches & Steps

Missing Guardrail
Exterior - Rear

Part of the back deck did not have a guardrail along the outside edge. Based on the deck's height, a guardrail would be recommended.

Contractor Qualified Professional
$
Credit
Comment
4.6.3 - Decks, Balconies, Porches & Steps

Wood Damage
Exterior - Rear

The wood on the back deck shows signs of weathering and deterioration. Recommend thoroughly cleaning the surface and and painting/staining. Any pieces of wood that are significantly damaged should be replaced.

Tools Handyman/DIY
$
Credit
Comment
4.9.1 - Lighting

Missing Covers

The recessed light fixtures on the front porch did not have water-proof covers. Recommend they be installed.

Tools Handyman/DIY

5 - Garage

IN NI NP O
5.1 Ceiling X
5.2 Floor X
5.3 Walls & Firewalls X
5.4 Garage Door X
5.5 Garage Door Opener X
5.6 Occupant Door (From garage to inside of home) X
Garage Door: Material
Aluminum
Garage Door: Type
Automatic
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
5.3.1 - Walls & Firewalls

Damaged Drywall

Observed damaged drywall along one of the walls in the garage. The wood framing behind also showed signs of moisture intrusion. Further evaluation and repair recommended.

Contractor Qualified Professional
$
Credit
Comment
5.4.1 - Garage Door

Moisture Intrusion

Observed signs of moisture intrusion at the bottom of the the side jamb. Repair recommended.

Contractor Qualified Professional

6 - Heating and Cooling

IN NI NP O
6.1 Equipment X
6.2 Normal Operating Controls X
6.3 Distribution Systems X
6.4 Vents, Flues & Chimneys X
6.5 Presence of Installed Heating and Cooling Source in Each Room X
Equipment: Energy Source
Electric
Equipment: Heat Type
Heat Pump
Distribution Systems: Ductwork
Insulated
Equipment: Brand
Rheem

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
6.1.1 - Equipment

Service Recommended

Problems with one of the units was reported prior to the inspection. Recommend further evaluation and service of all equipment by an HVAC technician.

Fire HVAC Professional

7 - Attic, Insulation & Ventilation

IN NI NP O
7.1 Attic Insulation X
7.2 Vapor Retarders (Crawlspace or Basement) X
7.3 Ventilation X
7.4 Exhaust Systems X
Dryer Vent
Unknown
Attic Insulation: Insulation Type
Batt, Fiberglass
Ventilation: Ventilation Type
Soffit Vents

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
7.3.1 - Ventilation

Missing Exhaust Vents

The roof does not have any form of exhaust ventilation (i.e., ridge or box vents). Further evaluation recommended to ensure proper attic ventilation.

Contractor Qualified Professional
$
Credit
Comment
7.4.1 - Exhaust Systems

Unsecured Bathroom Fan Cover
1st Floor Bathroom (hallway near master bedroom)

One of the bathroom fan covers is not fully secured to the ceiling. Recommend securing flush against the surface. Likewise for the top piece on the master bedroom ceiling fan.

Tools Handyman/DIY

8 - Plumbing

IN NI NP O
8.1 Main Water Shut-off Device X
8.2 Drain, Waste, & Vent Systems X
8.3 Water Supply, Distribution Systems & Fixtures X
8.4 Hot Water Systems, Controls, Flues & Vents X
8.5 Fuel Storage & Distribution Systems X
8.6 Sump Pump X
Filters
Unknown
Water Source
Public
Drain, Waste, & Vent Systems: Drain Size
2"
Drain, Waste, & Vent Systems: Material
PVC
Water Supply, Distribution Systems & Fixtures: Distribution Material
Copper
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Galvanized
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Electric
Hot Water Systems, Controls, Flues & Vents: Capacity
47 gallons
Hot Water Systems, Controls, Flues & Vents: Location
Attic
Hot Water Systems, Controls, Flues & Vents: Manufacturer
Bradford & White

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
8.2.1 - Drain, Waste, & Vent Systems

No Vertical Plumbing Stacks

There are no plumbing vent stacks visible on the roof. Recommend further evaluation to determine if the current ventilation methods are adequate.

Contractor Qualified Professional
$
Credit
Comment
8.2.2 - Drain, Waste, & Vent Systems

Rust, Corrosion
Bathrooms

Observed rust and corrosion on some of the sink tailpiece fittings. There were no active leaks at the time of inspection, however, enough rust has formed that replacing the fittings is necessary to prevent future leaks.

Contractor Qualified Professional
$
Credit
Comment
8.3.1 - Water Supply, Distribution Systems & Fixtures

Outdoor Faucet Leak
Exterior - Deck

Observed a leak around one of the outdoor faucet knobs. Recommend adjustment or repair.

Tools Handyman/DIY
$
Credit
Comment
8.3.2 - Water Supply, Distribution Systems & Fixtures

Prior Repairs

Seller disclosed a previous toilet leak in the 2nd floor bathroom. Some of the nearby tile grout was damp so further evaluation would be wise. It's likely that the previous leak is what caused the ceiling stains in the master bedroom closet. The 1st floor toilet near the laundry room was loose and also showed signs of moisture on the floor. 

Contractor Qualified Professional

9 - Electrical

IN NI NP O
9.1 Service Entrance Conductors X
9.2 Service Panel/Box X
9.3 Branch Wiring Circuits, Breakers & Fuses X
9.4 Lighting Fixtures, Switches & Receptacles X
9.5 GFCI & AFCI X
9.6 Smoke Detectors X
9.7 Carbon Monoxide Detectors X
Service Size Voltage
240 Volts
Service Size Amperage
200-Amps
Service Entrance Conductors: Electrical Service Conductors
Below Ground
Service Panel/Box: Main Panel Location
Garage
Service Panel/Box: Panel Capacity
200 AMP
Service Panel/Box: Panel Manufacturer
Unknown
Branch Wiring Circuits, Breakers & Fuses: Branch Wire 15 and 20 AMP
Copper
Service Panel/Box: Panel Type
Circuit Breaker
Branch Wiring Circuits, Breakers & Fuses: Wiring Method
Romex
Service Panel/Box: Sub Panel Location
Garage, Exterior, Attic

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
9.3.1 - Branch Wiring Circuits, Breakers & Fuses

Condensation
Garage

The breakers for the garage HVAC unit have a fair amount of condensation on the surface. Recommend evaluation and repair as part of the HVAC service mentioned elsewhere in this report.

Th Heating and Cooling Contractor
$
Credit
Comment
9.3.2 - Branch Wiring Circuits, Breakers & Fuses

Missing Junction Box
Garage

The thermostat wiring connections for the garage HVAC unit are exposed. Recommend enclosing all connections within a junction box.

Contractor Qualified Professional
$
Credit
Comment
9.4.1 - Lighting Fixtures, Switches & Receptacles

Reversed Polarity
Master Bedroom

One of the master bedroom floor receptacles has the hot and neutral wires reversed. Repair recommended.

Contractor Qualified Professional
$
Credit
Comment
9.4.2 - Lighting Fixtures, Switches & Receptacles

Faulty Receptacles
Various

Many interior and exterior floor receptacle were damaged, obstructed, or inoperable. It's possible that these issues are the result of a broader problem with the electrical system (as oppose to just the individual outlets). Evaluation and repair by an electrician is strongly encouraged.

Electric Electrical Contractor
$
Credit
Comment
9.4.3 - Lighting Fixtures, Switches & Receptacles

Missing Covers

There were a few receptacles that were missing covers as well as a junction box in the attic. Recommend installing covers.

Wrench DIY
$
Credit
Comment
9.4.4 - Lighting Fixtures, Switches & Receptacles

Loose Receptacles

A few interior receptacles were moderately loose. Recommend they be secured to prevent weakened electrical connections.

Contractor Qualified Professional
$
Credit
Comment
9.4.5 - Lighting Fixtures, Switches & Receptacles

Missing Water-proof Covers
Master Bathroom

The recessed lights in the master bathroom are missing covers. Because bathrooms are considered damp locations, adding covers is recommended.

Tools Handyman/DIY

10 - Interior

IN NI NP O
10.1 Doors X
10.2 Windows X
10.3 Floors X
10.4 Walls X
10.5 Ceilings X
10.6 Steps, Stairways & Railings X
10.7 Countertops & Cabinets X
Windows: Window Manufacturer
Unknown
Floors: Floor Coverings
Carpet, Laminate, Tile
Walls: Wall Material
Gypsum Board
Countertops & Cabinets: Countertop Material
Granite
Countertops & Cabinets: Cabinetry
Wood
Windows: Window Type
Double-hung, Single-hung
Ceilings: Ceiling Material
Gypsum Board

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
10.1.1 - Doors

Unable to Lock
1st Floor Bathroom

The locking mechanism on some of the sliding doors doesn't seem to work. Consider replacement.

Tools Handyman/DIY
$
Credit
Comment
10.2.1 - Windows

Failed Seals
Various

Condensation was observed on several windows. This indicates a failed seal and could result in energy loss and damage to the wooden frames. Repair recommended.

Contractor Qualified Professional
$
Credit
Comment
10.3.1 - Floors

Damage - Minor

Observed a few small tile cracks, carpet stains, tears, and evidence of moisture intrusion on some of the laminate flooring. Recommend further evaluation of the laminate flooring that has moisture damage.

$
Credit
Comment
10.4.1 - Walls

Unsecured Baseboard
2nd Floor

A section of baseboard in the upstairs living area is partially detached from the wall. Recommend securing.

Wrench DIY
$
Credit
Comment
10.4.2 - Walls

Damage - Minor

Observed some minor damage to the drywall and trim pieces at various locations within the home. Consider repair.

Wrench DIY
$
Credit
Comment
10.5.1 - Ceilings

Damage - Minor

Observed minor drywall damage such as joint separation, flaking paint and stains. Recommend monitoring the areas that have stains for possible leaks.

Tools Handyman/DIY
$
Credit
Comment
10.6.1 - Steps, Stairways & Railings

Missing Banisters

Observed a few missing and unsecured banisters along the interior stairway. Repair/replacement recommended.

Tools Handyman/DIY
$
Credit
Comment
10.7.1 - Countertops & Cabinets

Unsecured Vanity Door
Master Bathroom

One of the doors on the master bathroom vanity is not fully attached. Repair recommended.

Tools Handyman/DIY
$
Credit
Comment
10.7.2 - Countertops & Cabinets

Damage - Minor
1st Floor Bathroom (near laundry room)

One of the 1st floor bathroom vanities has surface damage. This is cosmetic in nature.

11 - Appliances

IN NI NP O
11.1 Dishwasher X
11.2 Garbage Disposal
11.3 Range/Oven/Cooktop X
11.4 Microwave X
11.5 Refrigerator X
Dishwasher: General Comments

Dishwasher functioned properly at the time of inspection. 

Range/Oven/Cooktop: Range/Oven Energy Source
Electric
Range/Oven/Cooktop: Exhaust Hood Type
None
Range/Oven/Cooktop: General Comments

Range/cooktop functioned properly at the time of inspection.

Refrigerator: General Comments

Refrigerator functioned properly at the time of inspection.

Refrigerator: Brand
Maytag
Dishwasher: Brand
Maytag
Range/Oven/Cooktop: Range/Oven Brand
Maytag

10.1 The inspector shall inspect: F. installed ovens, ranges, surface cooking appliances, microwave ovens, dishwashing machines, and food waste grinders by using normal operating controls to activate the primary function. 10.2 The inspector is NOT required to inspect: G. installed and free-standing kitchen and laundry appliances not listed in Section 10.1.F. H. appliance thermostats including their calibration, adequacy of heating elements, self cleaning oven cycles, indicator lights, door seals, timers, clocks, timed features, and other specialized features of the appliance. I. operate, or con rm the operation of every control and feature of an inspected appliance.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
11.4.1 - Microwave

General Comments

Microwave functioned properly at the time of inspection. It was, however, missing the glass turn table.

12 - Pests

IN NI NP O
12.1 Spiders X
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • O = Observations
$
Credit
Comment
12.1.1 - Spiders

Treatment Recommended
Deck, Kitchen

Observed Brown Recluse spiders inside the home and on the deck. Recommend interior and exterior treatment.

Pest control Pest Control Pro