Viewing:

1234 Main St.
St. Croix Falls, WI 54024
12/05/2019 9:00AM

Sample agent
agent

Agent Name

Agency Name
73
Items Inspected
8
Maintenance item
28
Recommendation
4
Safety hazard

1 - Inspection Details

Age Of Building
25 - 30 Years
In Attendance
Client, Client's Agent, Tenant
Occupancy
Furnished, Occupied, Utilities On
Style
Single Family Home
Temperature (approximate)
75 Fahrenheit (F)
Type of Building
Single Family
Weather Conditions
Dry, Hot
5 Year Homes

Homes more than 5 years old may have areas that are not current in code requirements. This is not a new home and this home cannot be expected to meet current code standards. While this inspection makes every effort to point out safety issues, it does not inspect for code. It is common that homes of any age will have had repairs performed and some repairs may not be in a workmanlike manner. Some areas may appear less than standard. This inspection looks for items that are not functioning as intended. It does not grade the repair. It is sometimes common to see old plumbing or mixed materials. Sometimes water signs in crawlspaces or basements could be years old from a problem that no longer exists. Or, it may still need further attention and repair. Determining this can be difficult in a lived in home. Sometimes homes have signs of damage to wood from wood eating insects. Having this is typical and fairly common. If the home inspection reveals signs of damage you should have a pest control company inspect further for activity and possible hidden damage. The home inspection does not look for possible manufacturer re-calls on components that could be in this home. Always consider hiring the appropriate expert for any repairs or further inspection.

Report

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

2 - Roof

IN NI NP RR
2.1 Coverings X X
2.2 Roof Drainage Systems X X
2.3 Flashings X
2.4 Skylights, Chimneys & Other Roof Penetrations X
Inspection Method
Binoculars, Ground, Ladder
Roof Type/Style
Gable
Coverings: Material
Asphalt, 3-Tab
Roof Drainage Systems: Gutter Material
Aluminum
Flashings: Material
Metal

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed
Credit
Comment
2.1.1 - Coverings

Damaged (General)

Roof coverings showed moderate damage. Recommend a qualified roofing professional evaluate and repair. 

Credit
Comment
2.1.2 - Coverings

Moss On Roof

Moss was growing on the roof. As a result, shingles can lift or be damaged. Leaks can result and/or the roof surface can fail prematurely. Efforts should be made to kill the moss during its growing season (wet months). Typically, zinc or phosphate-based chemicals are used for this and must be applied periodically.

Contractor Qualified Professional
Credit
Comment
2.1.3 - Coverings

Multiple Layers

This asphalt or fiberglass composition roof surface appeared to have two or more layers of shingles. Additional layers of composition shingles typically last only 80% of their rated life, and the shingle manufacturer's warranty may be voided. The client should be aware that all layers of roofing will need to be removed when this roof surface needs replacing.

Contractor Qualified Professional
Credit
Comment
2.2.1 - Roof Drainage Systems

Debris

Debris has accumulated in the gutters. Recommend cleaning to facilitate water flow.

Here is a DIY resource for cleaning your gutters. 

Credit
Comment
2.2.2 - Roof Drainage Systems

Downspouts Drain Near House

One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement and/or water intrusion Recommend a qualified contractor adjust downspout extensions to drain at least 6 feet from the foundation. 

Here is a helpful DIY link and video on draining water flow away from your house. 

Credit
Comment
2.3.1 - Flashings

Loose/Separated/Substandard

Flashings observed to be loose or separated or improper materials / installation used, which can lead to water intrusion and/or mold. Recommend a qualified roofing contractor repair. 

3 - Exterior

IN NI NP RR
3.1 Siding, Flashing & Trim X X
3.2 Exterior Doors X X
3.3 Walkways, Patios & Driveways X
3.4 Decks, Balconies, Porches & Steps X X
3.5 Eaves, Soffits & Fascia X
3.6 Vegetation, Grading, Drainage & Retaining Walls X X
Inspection Method
Visual
Siding, Flashing & Trim: Siding Material
Wood
Exterior Doors: Exterior Entry Door
Steel
Walkways, Patios & Driveways: Driveway Material
Gravel
Decks, Balconies, Porches & Steps: Appurtenance
Deck
Decks, Balconies, Porches & Steps: Material
Wood

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed
Credit
Comment
3.1.1 - Siding, Flashing & Trim

Siding Needs Paint / Stain

The paint or stain finish over much of the entire structure was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture. Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the entire building exterior per standard building practices. Any repairs needed to the siding or trim should be made prior to this.

Contractor Qualified Professional
Credit
Comment
3.2.1 - Exterior Doors

Storm Door Damaged
Rear of Home

The storm door is damaged. Recommend replacing.

Contractor Qualified Professional
Credit
Comment
3.4.1 - Decks, Balconies, Porches & Steps

Joist Hangers

Joist hanger(s) are missing or improperly installed. This could cause the stairs to fail. Recommend that joist hangers be properly installed by qualified contractor.

Credit
Comment
3.4.2 - Decks, Balconies, Porches & Steps

Ledger Board Improperly Installed

The ledger board is not properly attached to the building. This can cause the deck to pull away from the building and possibly collapse. Recommend that the deck and/or ledger board be properly attached by qualified contractor.

Credit
Comment
3.4.3 - Decks, Balconies, Porches & Steps

Posts in Soil

Soil was in contact with one or more wooden deck, porch or balcony support posts. This is a conducive condition for wood destroying organisms. Even if posts are made of treated wood, the cut ends below soil may not have been field treated. Recommend grading soil or repairing as necessary to prevent wood-soil contact.

Contractor Qualified Professional
Credit
Comment
3.6.1 - Vegetation, Grading, Drainage & Retaining Walls

Vegetation

Vegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Tree limbs can damage roofing materials. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.

Yard scissors Tree Service
Credit
Comment
3.6.2 - Vegetation, Grading, Drainage & Retaining Walls

Negative Grading

Grading is sloping towards the home in some areas. This could lead to water intrusion and foundation issues. Recommend qualified landscaper or foundation contractor regrade so water flows away from home.

Here is a helpful article discussing negative grading. 

4 - Basement, Foundation, Crawlspace & Structure

IN NI NP RR
4.1 Foundation X
4.2 Basements & Crawlspaces X
4.3 Floor Structure X
4.4 Wall Structure X
4.5 Ceiling Structure X
4.6 Roof Structure & Attic X
Inspection Method
Visual, From Entry
Foundation: Material
Concrete
Floor Structure: Basement/Crawlspace Floor
Concrete
Floor Structure: Material
Concrete, Slab
Floor Structure: Sub-floor
Plywood
Roof Structure & Attic: Type
Gable
Roof Structure & Attic: Material
Engineered Wood Trusses

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed
Credit
Comment
4.2.1 - Basements & Crawlspaces

Past Water Intrusion
Basement

Evidence of prior water intrusion was found in one or more sections of the basement. For example, water stains or rust at support post bases, efflorescence on the foundation, etc. Accumulated water is a conducive condition for wood-destroying organisms and should not be present in the basement. Recommend reviewing any disclosure statements available and ask the property owner about past accumulation of water in the basement. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, then recommend that a qualified contractor who specializes in drainage issues evaluate and repair as necessary. Typical repairs for preventing water from accumulating in basements include:
Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
Improving perimeter grading
Repairing, installing or improving underground footing and/or curtain drains
Ideally, water should not enter basements, but if water must be controlled after it enters the basement, then typical repairs include installing a sump pump.

Water Waterproofing Contractor

5 - Heating

IN NI NP RR
5.1 Equipment X X
5.2 Normal Operating Controls X
5.3 Distribution Systems X
5.4 Presence of Installed Heat Source in Each Room X
Equipment: Brand
Goodman
Equipment: Energy Source
Propane
Equipment: Heat Type
Forced Air
Distribution Systems: Ductwork
Non-insulated
AFUE Rating
90

AFUE (Annual fuel utilization efficiency) is a metric used to measure furnace efficiency in converting fuel to energy. A higher AFUE rating means greater energy efficiency. 90% or higher meets the Department of Energy's Energy Star program standard.

Normal Operating Controls: Thermostat Returned

View showing thermostat returned to original settings when the home inspection was completed 

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed
Credit
Comment
5.1.1 - Equipment

Needs Servicing/Cleaning

Furnace should be cleaned and serviced annually. Recommend a qualified HVAC contractor clean, service and certify furnace.

Here is a resource on the importance of furnace maintenance.

Credit
Comment
5.1.2 - Equipment

Older Furnace

The estimated useful life for most forced air furnaces is 15-20 years. The inspector was unable to determine the age of the furnace. Be aware that this furnace may be near, at, or beyond its useful life and may need replacing or significant repairs at any time. Recommend attempting to determine the furnace's age (ask property owner or service technician), and budgeting for a replacement if necessary.

Contractor Qualified Professional
Credit
Comment
5.1.3 - Equipment

Corrosion

Furnace was corroded in one or more areas. This could be the result of improper venting, which the source would need to be identified. Recommend a HVAC contractor evaluate and repair.

6 - Cooling

IN NI NP RR
6.1 Cooling Equipment X
6.2 Normal Operating Controls X
6.3 Distribution System X
6.4 Presence of Installed Cooling Source in Each Room X
Cooling Equipment: Energy Source/Type
Electric
Distribution System: Configuration
Central
Cooling Equipment: Brand
Allegiance

I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed

7 - Plumbing

IN NI NP RR
7.1 Main Water Shut-off Device X
7.2 Drain, Waste, & Vent Systems X X
7.3 Water Supply, Distribution Systems & Fixtures X X
7.4 Hot Water Systems, Controls, Flues & Vents X
7.5 Fuel Storage & Distribution Systems X
7.6 Sump Pump X
7.7 Private Well X X
7.8 Private Septic X X
7.9 Sewer Ejector Pump X
Filters
None
Water Source
Well
Drain, Waste, & Vent Systems: Material
PVC
Water Supply, Distribution Systems & Fixtures: Distribution Material
Copper
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Black Hose
Hot Water Systems, Controls, Flues & Vents: Capacity
110 gallons
Hot Water Systems, Controls, Flues & Vents: Location
Basement
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Electric
Sump Pump: Location
Not applicable
Private Well: Private Well
Private Septic: Private Septic System
Main Water Shut-off Device: Location
Basement, Lever, At Pressure Tank
Fuel Storage & Distribution Systems: Main Gas Shut-off Location
At Tank
Hot Water Systems, Controls, Flues & Vents: Manufacturer
Marathon

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

Private Well: Private Well

Based on visible equipment or information provided to the inspector, the water supply to this property appeared to be from a private well. Private well water supplies are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. The inspector does not test private well water for contamination or pollutants, determine if the supply and/or flow are adequate, or provide an estimate for remaining life of well pumps, pressure tanks or equipment. Only visible and accessible components are evaluated. Recommend the following:

That a qualified well contractor fully evaluate the well, including a pump/flow test
That the well water be tested per the client's concerns (coliforms, pH, contaminants, etc.
Research the well's history (how/when constructed, how/when maintained or repaired, past performance, past health issues)
Document the current well capacity and water quality for future reference

Private Septic: Private Septic System

Based on visible components or information provided to the inspector, this property appeared to have a private sewage disposal (septic) system. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. Generally, septic tanks should be pumped and inspected every 3 years. Depending on the type of system and municipal regulations, inspection and maintenance may be required more frequently, often annually. Recommend the following:

Consult with the property owner about this system's maintenance and repair history
Review any documentation available for this system
Review inspection and maintenance requirements for this system
That a qualified specialist evaluate, perform maintenance and make repairs if necessary

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed
Credit
Comment
7.2.1 - Drain, Waste, & Vent Systems

Improper Connection

An improper connection was observed at a drain, waste or vent pipe. Recommend a qualified plumber evaluate and repair.
Credit
Comment
7.2.2 - Drain, Waste, & Vent Systems

Toilet Loose at Floor

The toilet is loose at floor at the bath. Repairs may involve re-setting the toilet on a new wax seal. I recommend a qualified licensed plumber repair or correct as needed.

Contractor Qualified Professional
Credit
Comment
7.3.1 - Water Supply, Distribution Systems & Fixtures

No/Low Water Pressure

The water supply pressure was below 40 pounds per square inch (PSI), and the flow appeared to be inadequate. 40-60 PSI is considered the normal range for water pressure in a home. The inspector performed a "functional flow test" during the inspection, where multiple fixtures are run simultaneously, and found there to be low flow. For example, the shower flow decreased significantly when the toilet was flushed. Recommend that a qualified plumber evaluate and repair or make modifications as necessary.

Pipes Plumbing Contractor
Credit
Comment
7.3.2 - Water Supply, Distribution Systems & Fixtures

Loose fixture

The shower head was loose in the wall. Damage to the pipe can occur causing water damage in the home..I recommend having a licensed plumber evaluate and repair as needed.

Pipes Plumbing Contractor

8 - Electrical

IN NI NP RR
8.1 Service Entrance Conductors X
8.2 Main & Subpanels, Service & Grounding, Breakers & Fuses X
8.3 Branch Wiring Circuits, X
8.4 Lighting Fixtures, Switches & Receptacles, GFCI X X
8.5 Smoke Detectors X X
8.6 Carbon Monoxide Detectors X X
Service Entrance Conductors: Electrical Service Conductors
Below Ground
Main & Subpanels, Service & Grounding, Breakers & Fuses: Panel Capacity
200 AMP
Main & Subpanels, Service & Grounding, Breakers & Fuses: Panel Manufacturer
Square D
Main & Subpanels, Service & Grounding, Breakers & Fuses: Panel Type
Circuit Breaker
Main & Subpanels, Service & Grounding, Breakers & Fuses: Sub Panel Location
None
Branch Wiring Circuits, : Branch Wire 15 and 20 AMP
Copper
Branch Wiring Circuits, : Wiring Method
Romex
View Of Electric Meter
Main & Subpanels, Service & Grounding, Breakers & Fuses: Main Panel Location
Garage

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed
Credit
Comment
8.4.1 - Lighting Fixtures, Switches & Receptacles, GFCI

Cover Plates Damaged

One or more receptacles have a damaged cover plate. Recommend replacement.
Credit
Comment
8.4.2 - Lighting Fixtures, Switches & Receptacles, GFCI

Cover Plates Missing

One or more cover plates for switches, receptacles (outlets) or junction boxes were missing or broken. These plates are intended to contain fire and prevent electric shock from occurring due to exposed wires. Recommend that a qualified person install cover plates where necessary.

Credit
Comment
8.4.3 - Lighting Fixtures, Switches & Receptacles, GFCI

Not GFCI Protected

One or more electric receptacles (outlets) had no visible ground fault circuit interrupter (GFCI) protection, or the inspector was unable to determine if GFCI protection was present. If not GFCI-protected, receptacles in wet areas pose a shock hazard. Recommend that a qualified electrician evaluate and install GFCI protection if necessary and per standard building practices. General guidelines for GFCI-protected receptacles include the following locations:

  • Outdoors (since 1973)
  • Bathrooms (since 1975)
  • Garages (since 1978)
  • Kitchens (since 1987)
  • Crawl spaces and unfinished basements (since 1990)
  • Wet bar sinks (since 1993)
  • Laundry and utility sinks (since 2005)
Electric Electrical Contractor
Credit
Comment
8.4.4 - Lighting Fixtures, Switches & Receptacles, GFCI

No Power

One or more electric receptacles (outlets) appeared to have no power. Recommend asking the property owner about this. Switches may need to be operated to make some receptacles energized. If necessary, recommend that a qualified electrician evaluate and repair.

Contractor Qualified Professional
Credit
Comment
8.4.5 - Lighting Fixtures, Switches & Receptacles, GFCI

Missing Globe

One or more globes or covers for light fixtures were missing or damaged. Recommend replacing as necessary to avoid exposed bulbs. With closet lighting or where flammable stored objects are near light fixtures, missing or broken covers can be a fire hazard.

Contractor Qualified Professional
Credit
Comment
8.4.6 - Lighting Fixtures, Switches & Receptacles, GFCI

Damaged Ceiling Fan
Bedroom

The ceiling fan was not installed properly and is wobbly. Recommend having it repaired. 

Contractor Qualified Professional
Credit
Comment
8.5.1 - Smoke Detectors

Smoke Detector

The functionality of, power source for and placement of smoke alarms is not determined as part of this inspection. Smoke alarms should be installed in each bedroom, in hallways leading to bedrooms, on each level and in attached garages. They have a limited lifespan and should be replaced every 10 years. Batteries in smoke alarms should be changed when taking occupancy and annually in the future. Carbon monoxide alarms should be installed near sleeping areas and on each level in homes with a fuel-burning appliance or attached garage.

Contractor Qualified Professional
Credit
Comment
8.5.2 - Smoke Detectors

Defective

Smoke detector is connected, but not functioning properly. Recommend replacement.
Credit
Comment
8.6.1 - Carbon Monoxide Detectors

Check CO Detector

Recommend checking and or replacing carbon monoxide detectors upon taking occupancy.

Contractor Qualified Professional

9 - Attic, Insulation & Ventilation

IN NI NP RR
9.1 Attic Insulation X
9.2 Vapor Retarders (Crawlspace or Basement) X
9.3 Ventilation X X
9.4 Exhaust Systems X X
Dryer Power Source
220 Electric
Dryer Vent
Vinyl (Flex)
Flooring Insulation
None
Attic Insulation: Insulation Type
Blown, Cellulose
Attic Insulation: R-value
50
Ventilation: Ventilation Type
Ridge Vents, Soffit Vents
Exhaust Systems: Exhaust Fans
Fan Only

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed
Credit
Comment
9.3.1 - Ventilation

Ridge Vent Improper Installation

The ridge vent was installed improperly and not venting the attic enough. Recommend having a qualified roofing contractor evaluate and repair as needed

Contractor Qualified Professional
Credit
Comment
9.4.1 - Exhaust Systems

Vinyl Duct

The clothes dryer was equipped with a vinyl or mylar, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. They can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow and cause overheating. Recommend that such ducts be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary.

Contractor Qualified Professional

10 - Doors, Windows & Interior

IN NI NP RR
10.1 Doors X
10.2 Windows X X
10.3 Floors X
10.4 Walls X X
10.5 Ceilings X X
10.6 Steps, Stairways & Railings X
10.7 Countertops & Cabinets X
Windows: Window Manufacturer
Unknown
Windows: Window Type
Single-hung
Floors: Floor Coverings
Carpet
Walls: Wall Material
Gypsum Board, Wood
Ceilings: Ceiling Material
Gypsum Board
Countertops & Cabinets: Cabinetry
Wood
Countertops & Cabinets: Countertop Material
Laminate
Rodents

Evidence of rodent infestation was found in the form of feces.insulation  in the interior rooms . Consult with the property owner about this. A qualified person should make repairs to seal openings in the structure, set traps, and clean rodent waste as necessary.

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed
Credit
Comment
10.2.1 - Windows

Failed Seal

Condensation or staining was visible between multi-pane glass in one or more windows
. This usually indicates that the seal between the panes of glass has failed or that the desiccant material that absorbs moisture is saturated. As a result, the view through the window may be obscured, the window's R-value will be reduced, and accumulated condensation may leak into the wall structure below. Recommend that a qualified contractor evaluate and repair windows as necessary. Usually, this means replacing the glass in window frames.Be aware that evidence of failed seals or desiccant may be more or less visible depending on the temperature, humidity, sunlight, etc. Windows or glass-paneled doors other than those that the inspector identified may also have failed seals and need glass replaced. It is beyond the scope of this inspection to identify every window with failed seals or desiccant.

Credit
Comment
10.2.2 - Windows

Broken Window

One or more windows have broken glass. Recommend repair or replace

Contractor Qualified Professional
Credit
Comment
10.4.1 - Walls

Moisture Damage

Stains on the walls visible at the time of the inspection appeared to be the result of moisture intrusion. The source of moisture may have been corrected. Recommend further examination by a qualified contractor to provide confirmation.

Credit
Comment
10.4.2 - Walls

Microbial Growth

Microbial growths were found at one or more locations in interior rooms. It is beyond the scope of this inspection to identify what substance or organism this staining is. However such staining is normally caused by excessively moist conditions, which in turn can be caused by plumbing or building envelope leaks and/or substandard ventilation. These conducive conditions should be corrected before making any attempts to remove or correct the staining. Normally affected materials such as drywall are removed, enclosed affected spaces are allowed to dry thoroughly, a mildewcide may be applied, and only then is drywall reinstalled. For evaluation and possible mitigation, consult with a qualified industrial hygienist or mold/moisture mitigation specialist.

Mold Mold Remediation Contractor
Credit
Comment
10.5.1 - Ceilings

Possible Mold

There are possible signs of fungi growth on ceiling. It is unknown if this is a safety hazard. Recommend a qualified mold inspector evaluate. Moisture meter read levels of 25% which means an active leak is present. 

11 - Garage

IN NI NP RR
11.1 Ceiling X X
11.2 Floor X
11.3 Walls & Firewalls X
11.4 Garage Door X X
11.5 Garage Door Opener X
11.6 Occupant Door (From garage to inside of home) X X
Type
Attached
Garage Door: Material
Insulated
Garage Door: Type
Sectional
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed
Credit
Comment
11.1.1 - Ceiling

Heating Duct in Garage

One or more registers for the HVAC system were installed so they opened into the garage. This forms a direct connection between the garage and living spaces in the house. This is a safety hazard for carbon monoxide poisoning, fumes and fire. Recommend that a qualified person remove the register and make permanent repairs to patch the ductwork per standard building practices.

Contractor Qualified Professional
Credit
Comment
11.4.1 - Garage Door

Weather Stripping

The garage door(s) at the garage needs weather stripping replaced at bottom. This is a maintenance issue and is for your information. I recommend a qualified garage door repairman correct as needed.

Contractor Qualified Professional
Credit
Comment
11.6.1 - Occupant Door (From garage to inside of home)

Not Self-closing

Door from garage to home should have self-closing hinges to help prevent spread of a fire to living space. Recommend a qualified contractor install self-closing hinges. 

DIY Resource Link.

12 - Built-in Appliances

IN NI NP RR
12.1 Dishwasher X
12.2 Refrigerator X
12.3 Range/Oven/Cooktop X
12.4 Garbage Disposal X
12.5 Built-in Microwave X
Dishwasher: Brand
None
Refrigerator: Brand
Amana
Range/Oven/Cooktop: Exhaust Hood Type
Re-circulate
Range/Oven/Cooktop: Range/Oven Brand
Kenmore
Range/Oven/Cooktop: Range/Oven Energy Source
Electric
  • IN = Inspected
  • NI = Not Inspected
  • NP = Not Present
  • RR = Repair/Replace or Further Evaluation Needed