1234 Main St.
Oreana IL 62554
12/16/2018 9:00AM

Sample agent
agent

Agent Name

Agency Name
52
Recommendation
1
Safety hazard

1 - Inspection Details

In Attendance
Home Owner
Occupancy
Furnished, Occupied, Utilities On
Style
Multi-level, Crawlspace
Temperature (approximate)
45 Fahrenheit (F)
Type of Building
Detached, Single Family
Weather Conditions
Cloudy, Light Rain

2 - Roof

D NP NI IN
2.1 Coverings X
2.2 Roof Drainage Systems X X
2.3 Flashings X
2.4 Skylights, Chimneys & Other Roof Penetrations X X
Inspection Method
Ladder, Eaves, Roof Surface
Roof Type/Style
Gable
Coverings: Material
Fiberglass
Roof Drainage Systems: Gutter Material
Not Present
Flashings: Material
Rubber
Roof Drainage Systems: Not Present

Construction is ongoing.  Drainage systems not installed.  Recommend having systems evaluated by a professional after installation.  

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
2.1.1 - Coverings

Improper/Incomplete Nailing

Roof coverings showed signs of improper installation and fastening. Recommend a qualified roofing contractor evaluate and repair. 

Roof Roofing Professional
Credit
Comment
2.1.2 - Coverings

Shingles Missing

Observed areas that appeared to be missing sufficient coverings. Recommend qualified roofing contractor evaluate & repair. 

Roof Roofing Professional
Credit
Comment
2.1.3 - Coverings

Evidence of Patching

During the inspection, I observed areas of patching.  This could indicate preventative patching or could indicate corrective repairs to prior leaking.  Recommend further evaluation or monitoring.  

Roof Roofing Professional
Credit
Comment
2.2.1 - Roof Drainage Systems

Downspouts Missing

Home was missing downspouts in one or more areas. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor install downspout extensions that drain at least 6 feet from the foundation. 

Roof Roofing Professional
Credit
Comment
2.2.2 - Roof Drainage Systems

Gutters Missing

There are no gutters present on the structure.  Gutters are recommended because they collect rain water from the roof and direct it away form the building.

Wrenches Handyman
Credit
Comment
2.3.1 - Flashings

pipe boot

The rubber pipe boot appears to be inverted at the collar. This can lead to leaking and premature failure due to ponding water and or snow/ice.   

Credit
Comment
2.4.1 - Skylights, Chimneys & Other Roof Penetrations

Chimney Cap Missing

No chimney cap was observed. This is important to protect from moisture intrusion, weathering and wildlife nesting.  Recommend a qualified roofer or chimney expert install.

Roof Roofing Professional
Credit
Comment
2.4.2 - Skylights, Chimneys & Other Roof Penetrations

Chimney Cap Improperly Installed
Chimney to indoor wood burning fireplace

Chimney cap was installed using flat plywood rather than recommended materials.  This will potentially result in wood rot and water intrusion.  Recommend chimney repair contractor install proper cap.

Fireplace Chimney Repair Contractor

3 - Exterior

D NP NI IN
3.1 Siding, Flashing & Trim X
3.2 Exterior Doors X X
3.3 Walkways, Patios & Driveways X X
3.4 Decks, Balconies, Porches & Steps X X
3.5 Eaves, Soffits & Fascia X
3.6 Vegetation, Grading, Drainage & Retaining Walls X
Inspection Method
Visual
Siding, Flashing & Trim: Siding Material
Brick Veneer, Vinyl, Wood
Siding, Flashing & Trim: Siding Style
Tongue and Groove
Exterior Doors: Exterior Entry Door
Steel, Wood
Walkways, Patios & Driveways: Driveway Material
Concrete, Dirt
Decks, Balconies, Porches & Steps: Appurtenance
Covered Porch, Front Porch, Patio, Sidewalk
Decks, Balconies, Porches & Steps: Material
Concrete
Decks, Balconies, Porches & Steps: Not Complete
Front and Rear Patio

Construction is ongoing so there are no steps leading to the front porch.  

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
3.1.1 - Siding, Flashing & Trim

Warping/Buckling
MULTIPLE LOCATIONS

Vinyl siding was warping or buckling in areas. This is often as a result of nailing siding boards to tight to the home, preventing expansion/contraction. Recommend a qualified siding contractor evaluate and repair.

Siding Siding Contractor
Credit
Comment
3.1.2 - Siding, Flashing & Trim

Trim improperly sealed
Trim between the siding and exterior brick fireplace

Trim is improperly sealed which could cause moisture intrusion.  Recommend proper sealing.

Tools Handyman/DIY
Credit
Comment
3.1.3 - Siding, Flashing & Trim

Wood Trim Exposed to Elements

Trim around exterior windows is wood material.  Does not seem to be treated or painted and is exposed to the elements.  Recommend treating and monitoring to prevent future wood rot and water intrusion.

Mag glass Monitor
Credit
Comment
3.2.1 - Exterior Doors

Garage doors

I was unable to test garage overhead doors due to ongoing construction and homeowners belongings.   

Credit
Comment
3.2.2 - Exterior Doors

Leaking
Garage

Water intrusion most likely due to improper installation or missing trim.  Recommend DIY or Qualified Professional to correct.

Contractor Qualified Professional
Credit
Comment
3.2.3 - Exterior Doors

Other Doors

I observed no indications of deficiencies in the Front or Rear entry doors during the time of inspection.

Credit
Comment
3.3.1 - Walkways, Patios & Driveways

Driveway Cracking - Minor

Minor cosmetic cracks observed, which may indicate movement in the soil. Recommend monitor and/or have concrete contractor patch/seal.

Gardening shovel tool shape Concrete Contractor
Credit
Comment
3.3.2 - Walkways, Patios & Driveways

Driveway Trip Hazard
Where the Driveway meets the Garage Floor

Trip hazards observed. Patch or repair recommended.  

Wrench DIY
Credit
Comment
3.4.1 - Decks, Balconies, Porches & Steps

Missing Stairs

Construction is ongoing so there are no steps leading to the front porch.  There are cutouts that may be foundation supports for future steps.  The rear patio has no steps leading up to the door for entry to the home.  Recommend stairs in both locations.

Contractor Qualified Professional
Credit
Comment
3.5.1 - Eaves, Soffits & Fascia

Wood Finish

Eaves, Soffits & Fascia are all wood material.  Recommend monitoring and maintenance as needed to prevent wood rot and water intrusion.

Contractor Qualified Professional
Credit
Comment
3.6.1 - Vegetation, Grading, Drainage & Retaining Walls

Negative Grading
Multiple Locations

Grading is sloping towards the home in some areas. This could lead to water intrusion and foundation issues. Recommend qualified landscaper or foundation contractor regrade so water flows away from home.

Here is a helpful article discussing negative grading. 

Yard scissors Landscaping Contractor
Credit
Comment
3.6.2 - Vegetation, Grading, Drainage & Retaining Walls

Incomplete grading

Construction still in progress, gutters have not been installed causing improper drainage.  This is creating a trench that is pushing water towards the foundation.  Recommend gutter installation and proper grading to prevent future water intrusion.

Triangle Grading Contractor

4 - Basement, Foundation, Crawlspace & Structure

D NP NI IN
4.1 Foundation X X
4.2 Basements & Crawlspaces X
4.3 Floor Structure X
4.4 Wall Structure X
4.5 Ceiling Structure X X
Inspection Method
Crawlspace Access, Visual
Foundation: Material
Masonry Block
Floor Structure: Material
Wood Beams
Floor Structure: Sub-floor
Plank
Floor Structure: Basement/Crawlspace Floor
Dirt
Wall Structure: Not Complete

Construction ongoing.  No deficiencies observed at this time.

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
4.1.1 - Foundation

Poor Ventilation of Foundation Area

The foundation is poorly ventilated. Increased ventilation (introduction and movement of fresh air) is recommended. This can be accomplished by partially opening basement windows, doors and/or vents on opposite sides of the foundation on a regular basis (when weather is suitable).  And by installing a dehumidifier to decrease moisture.

Contractor Qualified Professional
Credit
Comment
4.1.2 - Foundation

Water Intrusion

Water intrusion was evident on the surface of the floor slab or in the basement/crawlspace. This can compromise the soil's ability to stabilize the structure and could cause damage. Recommend a qualified contractor identify the source of moisture and remedy. 

House construction Structural Engineer
Credit
Comment
4.2.1 - Basements & Crawlspaces

Efflorescence

Efflorescence noted on the crawlspace surface. This a white, powdery deposit that is consistent with moisture intrusion. This can compromise the soil's ability to support the home structure and/or lead to mold growth. Recommend a qualified contractor identify source or moisture and correct. 

Contractor Qualified Professional
Credit
Comment
4.2.2 - Basements & Crawlspaces

High Moisture Levels

High levels of moisture were noted in areas of the basement. Recommend monitoring and finding source of moisture intrusion to prevent damage to structure. 

Contractor Qualified Professional
Credit
Comment
4.2.3 - Basements & Crawlspaces

Standing Water
Crawlspace

Observed signs that standing water may have been present on basement floor. Recommend a qualified contractor evaluate and find potential source of moisture. 

Contractor Qualified Professional
Credit
Comment
4.3.1 - Floor Structure

Evidence of Water Intrusion
Crawlspace

There were signs of water intrusion in the underlying floor structure. Recommend identifying source of moisture and repairing. 

House construction Structural Engineer
Credit
Comment
4.3.2 - Floor Structure

Mold
Crawlspace

Observed signs of mold in one or more areas in the flooring structure. Recommend identifying source or moisture intrusion and sending samples to a lab for testing. 

Hardhat Mold Inspector
Credit
Comment
4.5.1 - Ceiling Structure

Evidence of Water Intrusion
Bedroom 2nd Floor Closet

Ceiling structure showed signs of water intrusion, which could lead to more serious structural damage. Recommend a qualified contractor identify source or moisture and remedy.

Contractor Qualified Professional

5 - Heating

D NP NI IN
5.1 Equipment X X
5.2 Normal Operating Controls X
5.3 Distribution Systems X
5.4 Vents, Flues & Chimneys X
5.5 Presence of Installed Heat Source in Each Room X
Equipment: Brand
Goodman
Equipment: Energy Source
Electric
Equipment: Heat Type
Heat Pump
Distribution Systems: Ductwork
Insulated
AFUE Rating
80

AFUE (Annual fuel utilization efficiency) is a metric used to measure furnace efficiency in converting fuel to energy. A higher AFUE rating means greater energy efficiency. 90% or higher meets the Department of Energy's Energy Star program standard.

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
5.1.1 - Equipment

Inoperable

Heating element was inoperable at time of inspection. Recommend qualified HVAC professional evaluate & ensure functionality.

Fire HVAC Professional
Credit
Comment
5.1.2 - Equipment

Data plate
Heat Pump

Manufacturer Label

Credit
Comment
5.2.1 - Normal Operating Controls

Thermostat on but not working

The thermostat was set but not working.  Could not determine whether it was the heating system or the thermostat that was not functional.  Recommend further evaluation by qualified HVAC technician.  

Credit
Comment
5.3.1 - Distribution Systems

Duct improperly secured
Crawlspace

Ducts were not properly secured causing them to hang in areas.  This can make it more difficult for heat system to push air through.  Recommend HVAC technician evaluate and repair.

Fire HVAC Professional
Credit
Comment
5.4.1 - Vents, Flues & Chimneys

Good condition

Flues appeared to be in condition although there was evidence of water intrusion due to improper vent cap.

6 - Cooling

D NP NI IN
6.1 Cooling Equipment X
6.2 Normal Operating Controls X
6.3 Distribution System X
6.4 Presence of Installed Cooling Source in Each Room X
Cooling Equipment: Brand
Goodman
Cooling Equipment: Energy Source/Type
Heat Pump
Cooling Equipment: Location
Exterior West
Distribution System: Configuration
Central
Cooling Equipment: SEER Rating
15 SEER

Modern standards call for at least 13 SEER rating for new install. 

Read more on energy efficient air conditioning at Energy.gov.

Cooling Equipment: Low Temperature
The A/C unit was not tested due to low outdoor temperature. This may cause damage the unit.

I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected

7 - Plumbing

D NP NI IN
7.1 Main Water Shut-off Device X
7.2 Drain, Waste, & Vent Systems X
7.3 Water Supply, Distribution Systems & Fixtures X
7.4 Hot Water Systems, Controls, Flues & Vents X
7.5 Fuel Storage & Distribution Systems X X
7.6 Sump Pump X X
Filters
Unknown
Water Source
Public
Main Water Shut-off Device: Location
Unknown
Drain, Waste, & Vent Systems: Drain Size
2"
Drain, Waste, & Vent Systems: Material
PVC
Water Supply, Distribution Systems & Fixtures: Distribution Material
PVC
Water Supply, Distribution Systems & Fixtures: Water Supply Material
Pex
Hot Water Systems, Controls, Flues & Vents: Power Source/Type
Electric
Hot Water Systems, Controls, Flues & Vents: Capacity
40 gallons
Hot Water Systems, Controls, Flues & Vents: Location
Under Staircase
Fuel Storage & Distribution Systems: Main Gas Shut-off Location
Unknown
Sump Pump: Location
No sump pump found
Hot Water Systems, Controls, Flues & Vents: Manufacturer
Rheem

I recommend flushing & servicing your water heater tank annually for optimal performance. Water temperature should be set to at least 120 degrees F to kill microbes and no higher than 130 degrees F to prevent scalding. 

Here is a nice maintenance guide from Lowe's to help. 

Main Water Shut-off Device: Unknown

A main water shut off valve was not observed at the time of inspections.  I was unable to locate.  This could be due to obstruction or inspection limitations.

Water Supply, Distribution Systems & Fixtures: Incomplete

Construction is ongoing.  Plumbing incomplete.  I was unable to properly test functional flow and pressure of water.  However, the plumbing I was able to observe was functioning properly at time of inspection.  

Fuel Storage & Distribution Systems: No gas

No gas was observed in the home at time of inspection

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
7.3.1 - Water Supply, Distribution Systems & Fixtures

Incomplete plumbing

Construction is ongoing.  Plumbing incomplete.  I was unable to properly test functional flow and pressure of water.  However, the plumbing I was able to observe was functioning properly at time of inspection.  If you would like me to come back and check once complete, please call.

Pipes Plumbing Contractor
Credit
Comment
7.4.1 - Hot Water Systems, Controls, Flues & Vents

Corrosion

Corrosion was noted at the burn chamber or pipe fittings. Recommend a qualified plumber evaluate for repair/replacement.

Pipes Plumbing Contractor
Credit
Comment
7.4.2 - Hot Water Systems, Controls, Flues & Vents

No Drip Pan

No drip pan was present. Recommend installation by a qualified plumber.

Pipes Plumbing Contractor
Credit
Comment
7.4.3 - Hot Water Systems, Controls, Flues & Vents

No Expansion Tank

No expansion tank was present. Expansion tanks allow for the thermal expansion of water in the pipes. These are required in certain areas for new installs. Recommend a qualified plumber evaluate and install.
Pipes Plumbing Contractor

8 - Electrical

D NP NI IN
8.1 Service Entrance Conductors X
8.2 Main & Subpanels, Service & Grounding, Main Overcurrent Device X
8.3 Branch Wiring Circuits, Breakers & Fuses X
8.4 Lighting Fixtures, Switches & Receptacles X
8.5 GFCI & AFCI X
8.6 Smoke Detectors X
8.7 Carbon Monoxide Detectors X
Service Entrance Conductors: Electrical Service Conductors
Below Ground
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Main Panel Location
living room
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Capacity
200 AMP
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Manufacturer
Square D
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Panel Type
Circuit Breaker
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Sub Panel Location
not present
Branch Wiring Circuits, Breakers & Fuses: Branch Wire 15 and 20 AMP
Aluminum
Branch Wiring Circuits, Breakers & Fuses: Wiring Method
Romex
Main & Subpanels, Service & Grounding, Main Overcurrent Device: Missing knockouts

I did not remove the dead front cover on the electrical panel due to missing knockouts therefore, I was unable to determine if the fuses and breakers were wired correctly.  Recommend qualified electrician further evaluate.

Lighting Fixtures, Switches & Receptacles: Incomplete Wiring

Due to ongoing construction, the electrical is incomplete.

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
8.1.1 - Service Entrance Conductors

Main electrical service entrance

Credit
Comment
8.2.1 - Main & Subpanels, Service & Grounding, Main Overcurrent Device

Knockouts Missing

"Knockouts" are missing on the electric panel. This poses a safety hazard and it is recommended that the opening in the panel caused by the missing knockout(s) be properly sealed by a licensed electrician.

Electric Electrical Contractor
Credit
Comment
8.2.2 - Main & Subpanels, Service & Grounding, Main Overcurrent Device

Missing Labels on Panel

At the time of inspection, panel was missing labeling. Recommend a qualified electrician or person identify and map out locations. 

Electric Electrical Contractor
Credit
Comment
8.3.1 - Branch Wiring Circuits, Breakers & Fuses

Improper Wiring
Crawlspace

Wiring is run through flooring into the crawlspace.  The hole is jagged which may cause future fraying of the wire.  Recommend a qualified electrician further evaluate the wiring and electrical system.  

Electric Electrical Contractor
Credit
Comment
8.4.1 - Lighting Fixtures, Switches & Receptacles

Cover Plates Missing

One or more receptacles are missing a cover plate. This causes short and shock risk. Recommend installation of plates.
Electric Electrical Contractor
Credit
Comment
8.4.2 - Lighting Fixtures, Switches & Receptacles

Incomplete

Due to ongoing construction, several plate covers were missing.  There were outlets yet to be installed.  All receptacles did not have power or light fixtures were missing.  I did test a representative number of outlets and switches.  The ones that were tested seemed to be in working order.  

Electric Electrical Contractor
Credit
Comment
8.6.1 - Smoke Detectors

Smoke Detectors Installed

9 - Attic, Insulation & Ventilation

D NP NI IN
9.1 Attic Insulation X
9.2 Vapor Retarders (Crawlspace or Basement) X
9.3 Ventilation X
9.4 Exhaust Systems X X
9.5 Vapor Retarders (Crawlspace or Basement)
Dryer Power Source
220 Electric
Dryer Vent
Metal (Flex)
Flooring Insulation
None
Attic Insulation: Insulation Type
Fiberglass
Ventilation: Ventilation Type
Ridge Vents, Soffit Vents
Exhaust Systems: Exhaust Fans
None
Attic Insulation: Limited Access to Attic
Attic

Limited Access to some areas due to insulation.

Ventilation: Limited Access
Attic

Limited Access.  I was not able to observe all ventilation systems at the time of this inspection.  

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
9.1.1 - Attic Insulation

Attic Insulation Observed

Credit
Comment
9.2.1 - Vapor Retarders (Crawlspace or Basement)

No Vapor Barrier

There is no vapor barrier beneath the flooring. This can result in unwanted moisture.
House construction Insulation Contractor
Credit
Comment
9.3.1 - Ventilation

Missing Ventilation

 I was not able to observe all ventilation systems at the time of this inspection.  It is a possibility that the soffit vents were covered by insulation.  Recommend evaluate further.  Also observed no screen on the attic vent.  Recommend screen to prevent vermin from entering residence.  

10 - Doors, Windows & Interior

D NP NI IN
10.1 Doors X
10.2 Windows X
10.3 Floors X
10.4 Walls X
10.5 Ceilings X
10.6 Steps, Stairways & Railings X
10.7 Countertops & Cabinets X
Windows: Window Type
Single Pane
Windows: Window Manufacturer
Unknown
Floors: Floor Coverings
Hardwood, Unfinished
Walls: Wall Material
Drywall, Unfinished
Ceilings: Ceiling Material
Gypsum Board, Unfinished, Wood
Countertops & Cabinets: Countertop Material
Wood Butcher Block
Countertops & Cabinets: Cabinetry
Wood
Walls: Unfinished

Due to ongoing construction, walls were unfinished in several areas

Ceilings: Unfinished

Due to ongoing construction, ceilings were unfinished in some areas

Countertops & Cabinets: Unfinished
Kitchen

Due to ongoing construction, cabinets and countertops were not finished.  

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

  • D = Deficiency
  • NP = Not Present
  • NI = Not Inspected
  • IN = Inspected
Credit
Comment
10.2.1 - Windows

Windows Inspected

Credit
Comment
10.3.1 - Floors

Incomplete

Due to ongoing construction, many areas of flooring were not complete.  

Credit
Comment
10.4.1 - Walls

Incomplete

Due to ongoing construction in the home, many areas of drywall were not complete.  

Credit
Comment
10.5.1 - Ceilings

Stain(s) on Ceiling
Master closet

There is a stain on ceiling/wall that requires repair and paint.  Source of staining should be determined.

Contractor Qualified Professional
Credit
Comment
10.6.1 - Steps, Stairways & Railings

No Handrail
Staircase

Staircase had no handrails. This is a safety hazard. Recommend a qualified handyman install a handrail. 

Wrenches Handyman
Credit
Comment
10.7.1 - Countertops & Cabinets

Cabinet Door Missing

One or more cabinet doors were missing. 

House building Cabinet Contractor