All gutters in good shape with gutter covers installed.
Ryan Alexander
Anthony Graham
Nooks & Crannies Property Inspection LLC
IN | NI | NP | D | ||
---|---|---|---|---|---|
2.1 | Coverings | X | X | ||
2.2 | Roof Drainage Systems | X | |||
2.3 | Flashings | X | X | ||
2.4 | Skylights, Chimneys & Other Roof Penetrations | X | X | ||
2.5 | Roofing Underlayment | X |
All gutters in good shape with gutter covers installed.
Roof has two different aged shingles. Older on main house. Newer on shed roof of addition. Both in within its typical life span.
I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.
Roof shingles were discolored, which can be caused by moisture, rust or soot. Recommend a qualified roofing contractor evaluate and remedy with a roof cleaning or repair.
Here is a helpful article on common roof stains.
Ridge Cap has come disconnect.
Flashings observed to be loose or separated, which can lead to water intrusion and/or mold. Recommend a qualified roofing contractor repair.
Kick out flashings were missing at time of inspection also missing J channel is several places. Flashings provide protection against moisture intrusion. Recommend a qualified roofing contractor evaluate and remedy.
The chimney crown had one or more cracks, which can lead to further damage to the chimney structure as well as water infiltration. Recommend a qualified contractor repair.
Joints in the masonry have deteriorated and should be repointed. (Repointing is the restoration of the mortar joints in the masonry).
Vent boot shows signs of wear and pushed in, this could allow water to settle and make it's way down the pipe into the walls.
IN | NI | NP | D | ||
---|---|---|---|---|---|
3.1 | Structural Components & Observations in Attic | X | |||
3.2 | Insulation in Attic | X | |||
3.3 | Ventilation in Attic | X |
Structural components were inspected from the attic space according to the Home Inspection Standards of Practice.
During the home inspection, I inspected for ventilation in unfinished spaces, including attics, crawlspaces and foundation areas. And I inspected for mechanical exhaust systems.
I report as in need of correction the general absence of ventilation in unfinished spaces.
Mechanical ventilation in attic was running at time of inspection.
I could not see and inspect the attic space. The access is restricted and my inspection is limited.
Insulation in Attic not inspected.
The inspector shall inspect:
The inspector shall describe:
The inspector shall report as in need of correction:
I inspected the exterior of the house.
I inspected the exterior doors.
The exterior of your home is slowly deteriorating and aging. The sun, wind, rain and temperatures are constantly affecting it. Your job is to monitor the buildings exterior for its condition and weathertightness.
Check the condition of all exterior materials and look for developing patterns of damage or deterioration.
During a heavy rainstorm (without lightning), grab an umbrella and go outside. Walk around your house and look around at the roof and property. A rainstorm is the perfect time to see how the roof, downspouts and grading are performing. Observe the drainage patterns of your entire property, as well as the property of your neighbor. The ground around your house should slope away from all sides. Downspouts, surface gutters and drains should be directing water away from the foundation.
I inspected the eaves, soffits and fascia. I was not able to inspect every detail, since a home inspection is limited in its scope.
The exterior of your home is slowly deteriorating and aging. The sun, wind, rain and temperatures are constantly affecting it. Your job is to monitor the house's exterior for its condition and weathertightness.
Check the condition of all exterior wall-covering materials and look for developing patterns of damage or deterioration.
I observed minor indications of worn out areas, delayed maintenance, or aging.
I inspected the vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion.
I inspected ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible.
I inspected the walkways and driveways that were adjacent to the house. The walkways, driveways, and parking areas did show signs of age but still serviceable.
I inspected the stairs, steps, stoops, stairways and ramps that were within the scope of my home inspection.
All treads should be level and secure. Riser heights and tread depths should be as uniform as possible. As a guide, stairs must have a maximum riser of 7-3/4 inches and a minimum tread of 10 inches.
I inspected the porches, patios, decks, balconies and carports at the house that were within the scope of the home inspection.
I inspected the railings, guards and handrails that were within the scope of the home inspection.
A representative number of windows from the ground surface was inspected. Missing screens in multiple windows. Screens found in basement.
I did not inspect all of the eaves, soffit, and facia. It's impossible to inspect those areas closely during a home inspection. A home inspection is not an exhaustive evaluation. My inspection of the exterior was limited. I did not reach and access closely every part of the eaves, soffit, and fascia.
I did not inspect all of the exterior wall-covering material. A home inspection is not an exhaustive evaluation. My inspection of the exterior was limited. I did not reach and access closely every part of the exterior wall-covering.
I was unable to inspect every electrical component or proper installation of the GFCI system according to modern code. A licensed electrician or township building code inspector could perform that type of test, which is beyond the scope of my visual-only home inspection. I inspected the electrical system as much as I could according to the Home Inspection Standards of Practice.
At the time of inspections no outside power receptacles were noted.
I did not inspect all windows. I did inspect a representative number of them. It's impossible to inspect every window component closely during a home inspection. A home inspection is not an exhaustive evaluation. I did not reach and access closely every window, particularly those above the first floor level.
Please refer to the Home Inspection Standards of Practice related to inspecting the exterior of the house.
I. The inspector shall inspect:
II. The inspector shall describe:
III. The inspector shall report as in need of correction:
I observed that the condition of the fence in front gate area was in decay.
All underground drainage system is not connected. Some of the downspouts were connected. However one area was not. Consult owner for further details and exit point of system.
I observed a loose railing component. This condition is a safety hazard.
Correction and further evaluation is recommended.
I observed wood rot at the exterior door.
Correction and further evaluation is recommended.
Void in concrete at threshold could allow pest and water to infiltrate and damage wood floor.
IN | NI | NP | D | ||
---|---|---|---|---|---|
5.1 | Foundation | X | X |
I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.
Minor cracking was noted at the foundation. This is common as concrete ages and shrinkage surface cracks are normal. Recommend monitoring for more serious shifting/displacement.
Here is an informational article on foundation cracks.
Open hole to outside will allow water and pest to enter.
IN | NI | NP | D | ||
---|---|---|---|---|---|
6.1 | Equipment | X | |||
6.2 | Normal Operating Controls | X | |||
6.3 | Distribution Systems | X | |||
6.4 | Presence of Installed Heat Source in Each Room | X | |||
6.5 | Whole House Humidifier | X |
Changing filter on a regular basis will keep the system running better and for a longer period. Recommend having ducts cleaned on a regular basis. Also recommend have furnace professionally cleaned before turning on. Lots of dust and cobwebs were noted.
Recommend further inspection for serviceability. When unmaintained they become a source of possible mold and mildew growth
I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.
IN | NI | NP | D | ||
---|---|---|---|---|---|
7.1 | Cooling Equipment | X | |||
7.2 | Normal Operating Controls | X | |||
7.3 | Distribution System | X | |||
7.4 | Presence of Installed Cooling Source in Each Room | X |
I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.
IN | NI | NP | D | ||
---|---|---|---|---|---|
8.1 | Main Water Shut-Off Valve | X | |||
8.2 | Water Supply | X | |||
8.3 | Hot Water Source | X | X | ||
8.4 | Drain, Waste, & Vent Systems | X | |||
8.5 | Water Supply & Distribution Systems | X | X | ||
8.6 | Radon System | X |
I inspected the temperature and pressure relief valve.
It's your job to know where the main water and fuel shutoff valves are located. And be sure to keep an eye out for any water and plumbing leaks.
The water supply to the house appeared to be from the public water supply source based upon the observed indications at the time of the inspection. To confirm and be certain, I recommend asking the homeowner for details.
I inspected for the main source of the distributed hot water to the plumbing fixtures (sinks, tubs, showers). I recommend asking the homeowner for details about the hot water equipment and past performance.
I inspected the hot water source and equipment according to the Home Inspection Standards of Practice.
I attempted to inspect the drain, waste, and vent pipes. Not all of the pipes and components were accessible and observed. Inspection restriction. Ask the homeowner about water and sewer leaks or blockages in the past.
I attempted to inspect the water supply and distribution pipes (plumbing pipes). Not all of the pipes and components were accessible and observed. Inspection restriction. Ask the homeowner about water supply, problems with water supply, and water leaks in the past.
The inspection was restricted because not all of the pipes were exposed, readily accessible, and observed. For example, most of the drainage pipes were hidden within the walls.
The inspection was restricted because not all of the water supply pipes were exposed, readily accessible, and observed. For example, most of the water distribution pipes, valves and connections were hidden within the walls.
Radon System not present.
I. The inspector shall inspect:
II. The inspector shall describe:
III. The inspector shall report as in need of correction:
I observed that the hot water tank is missing a water leak catch pan.
I observed suspect vent connection pipe of the hot water source. Recommend contacting plumber who installed it for further guidance.
I observed an active water leak at a water shut-off valve on the front right exterior of house.
Water in upstairs bathroom tub would not shut off. I eventually shut the water off at service values in access panel in closet. Needs to be replaced or adjusted. This is a safety hazard.
Contact owners for further investigation
IN | NI | NP | D | ||
---|---|---|---|---|---|
9.1 | Electric Meter & Base | X | X | ||
9.2 | Service-Entrance Conductors | X | X | ||
9.3 | Main Service Disconnect | X | |||
9.4 | Electrical Wiring | X | X | ||
9.5 | Panelboards & Breakers | X | X | ||
9.6 | Service Grounding & Bonding | X | |||
9.7 | AFCIs | X | |||
9.8 | GFCIs | X | |||
9.9 | Electrical Defects | X | X |
I inspected the electrical electric meter and base.
I inspected the electrical service-entrance conductors.
I inspected the electrical main service disconnect.
I inspected the electrical service grounding and bonding.
It's your job to know where the main electrical panel is located, including the main service disconnect that turns everything off.
Be sure to test your GFCIs, AFCIs, and smoke detectors regularly. You can replace light bulbs, but more than that, you ought to hire an electrician. Electrical work is hazardous and mistakes can be fatal. Hire a professional whenever there's an electrical problem in your house.
I observed indications of the main service disconnect's amperage rating. It was labeled.
I inspected the electrical panelboards and over-current protection devices (circuit breakers and fuses).
I inspected the electrical subpanel and over-current protection devices (circuit breakers and fuses).
I inspected receptacles observed that were deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible.
I inspected ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible. Over use of GFCI is suspect.
I was unable to inspect all of the electrical wiring. Obviously, most of the wiring is hidden from view within walls. Beyond the scope of a visual home inspection.
I was unable to confirm proper installation of the system grounding and bonding according to modern code. A licensed electrician or township building code inspector could perform that type of test, which is beyond the scope of my visual-only home inspection. I inspected the grounding and bonding as much as I could according to the Home Inspection Standards of Practice.
I was unable to inspect every electrical component or proper installation of the AFCI system according to modern code. A licensed electrician or township building code inspector could perform that type of test, which is beyond the scope of my visual-only home inspection. I inspected the electrical system as much as I could according to the Home Inspection Standards of Practice.
I was unable to inspect every electrical component or proper installation of the GFCI system according to modern code. A licensed electrician or township building code inspector could perform that type of test, which is beyond the scope of my visual-only home inspection. I inspected the electrical system as much as I could according to the Home Inspection Standards of Practice.
I. The inspector shall inspect:
II. The inspector shall describe:
III. The inspector shall report as in need of correction:
I observed indications of a major defect during the inspection. Major defect. Hazard. Correction and further evaluation is recommended. Inquire with current owner where they are in the permitting process for better understanding.
I observed indications of a major defect during the inspection. Major defect. Hazard. Correction and further evaluation is recommended. Service cable is in close proximity to operable window. Contact local permitting for better clarity.
I observed indications of a major defect during the inspection. Major defect. Hazard. Correction and further evaluation is recommended. Cloth cover wire is extremely flammable. Contact a License electrical contractor for further evaluation
I observed missing/inadequate identification of each circuit.
Each circuit must be clearly identified as to its purpose. No two circuits should be labeled the same.
I observed indications of an improper location of a lighting fixture inside a clothes closet. Potential fire hazard.
An open incandescent light bulb is not allowed in a clothes closet.
The light bulb must have an adequate clearance between it and storage space.
Junction box to small to hold the amount of wire entering it. Would not close properly. Potential fire and safety hazard. Contact Licensed electrical contractor for further evaluation.
Potential shock/fire hazard
Several outlets in basement are loose and or possible installed incorrectly. Contact electrical contractor for further evaluation. Possible shock hazard.
IN | NI | NP | D | ||
---|---|---|---|---|---|
10.1 | Vents, Flues & Chimneys | X | |||
10.2 | Lintels | X | |||
10.3 | Damper Doors | X | |||
10.4 | Cleanout Doors & Frames | X |
New chimney liner noted. However recommend cleaning before use. Have it looked at when the crown is being repaired.
I. The inspector shall inspect: readily accessible and visible portions of the fireplaces and chimneys; lintels above the fireplace openings; damper doors by opening and closing them, if readily accessible and manually operable; and cleanout doors and frames.
II. The inspector shall describe: the type of fireplace.
III. The inspector shall report as in need of correction: evidence of joint separation, damage or deterioration of the hearth, hearth extension or chambers; manually operated dampers that did not open and close; the lack of a smoke detector in the same room as the fireplace; the lack of a carbon-monoxide detector in the same room as the fireplace; and cleanouts not made of metal, pre-cast cement, or other non-combustible material.
IV. The inspector is not required to: inspect the flue or vent system. inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels. Determine the need for a chimney sweep, perate gas fireplace inserts, light pilot flames, determine the appropriateness of any installation, inspect automatic fuel-fed devices, inspect combustion and/or make-up air devices, inspect heat-distribution assists, whether gravity-controlled or fan-assisted,ignite or extinguish fires, determine the adequacy of drafts or draft characteristics, move fireplace inserts, stoves or firebox contents, perform a smoke test, dismantle or remove any component, perform a National Fire Protection Association (NFPA)-style inspection perform a Phase I fireplace and chimney inspection.
IN | NI | NP | D | ||
---|---|---|---|---|---|
11.1 | Doors | X | |||
11.2 | Windows | X | |||
11.3 | Floors | X | |||
11.4 | Walls | X | |||
11.5 | Ceilings | X | |||
11.6 | Steps, Stairways & Railings | X | |||
11.7 | Countertops & Cabinets | X |
I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.
IN | NI | NP | D | ||
---|---|---|---|---|---|
12.1 | Bathroom Toilets | X | |||
12.2 | Sinks, Tubs & Showers | X | |||
12.3 | Bathroom Exhaust Fan / Window | X | X | ||
12.4 | GFCI & Electric in Bathroom | X | X | ||
12.5 | Heat Source in Bathroom | X | |||
12.6 | Cabinetry, Ceiling, Walls & Floor | X | |||
12.7 | Door | X |
I flushed all of the toilets.
I inspected the heat source in the bathroom (register/baseboard).
I ran water at all bathroom sinks, bathtubs, and showers. I inspected for deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously.
I inspected the GFCI-protection at the receptacle near the bathroom sink by pushing the test button at the GFCI device or using a GFCI testing instrument.
All receptacles in the bathroom must be GFCI protected.
The home inspector will inspect:
I observed that the bathroom fan is improperly exhausting air from the bathroom.
Exhaust air from bathrooms, toilet rooms, water closet compartments, and other similar rooms shall not be:
Venting has become crushed and detached going to the outside.
I observed a defect at the GFCI in the bathroom. It was not properly wired.
IN | NI | NP | D | ||
---|---|---|---|---|---|
13.1 | Clothes Washer | X | |||
13.2 | Clothes Dryer | X | X | ||
13.3 | Laundry Room, Electric, and Tub | X | |||
13.4 | Laundry Room Floor | X |
Hook up for were present
I did not inspect the clothes washer and dryer fully. These appliances are beyond the scope of a home inspection. I did not operate the appliances. The clothes dryer exhaust pipe must be inspected and cleaned every year to help prevent house fires.
I did not inspect the clothes washer and dryer fully. These appliances are beyond the scope of a home inspection. I did not operate the appliances. The clothes dryer exhaust pipe must be inspected and cleaned every year to help prevent house fires.
The inspector shall inspect:
I observed indications that the clothes dryer is not exhausting outside due to disconnected pipe. Venting into floor cavity. This is a fire and potential mold hazard
IN | NI | NP | D | ||
---|---|---|---|---|---|
14.1 | Dishwasher | X | |||
14.2 | Refrigerator | X | |||
14.3 | Range/Oven/Cooktop | X | |||
14.4 | Garbage Disposal | X |
No leaks were detected at the time of inspection. However the use of saddle values are common practice but need to be monitored from time to time as they are notorious for leaks.
IN | NI | NP | D | ||
---|---|---|---|---|---|
15.1 | Kitchen Sink | X | |||
15.2 | GFCI | X | |||
15.3 | AFCI | X | |||
15.4 | Countertops & Cabinets | X | |||
15.5 | Floors, Walls, Ceilings | X |
I ran water at the kitchen sink.
I inspected a representative number of cabinets and countertop surfaces.
I observed ground fault circuit interrupter (GFCI) protection in the kitchen. All were responsive however the overuse of them on every outlet is suspect.
I inspected the readily visible surfaces of floors, walls and ceilings. I looked for material defects according to the Home Inspection Standards of Practice.
The kitchen appliances are not included in the scope of a home inspection according to the Standards of Practice.
The inspector will out of courtesy only check: